Network Working Group                                    C.M. Heard, Ed.
 +
Request for Comments: 3637                                    Consultant
 +
Category: Standards Track                                September 2003
  
 +
                  Definitions of Managed Objects
 +
            for the Ethernet WAN Interface Sublayer
  
 +
'''Status of this Memo'''
  
 +
This document specifies an Internet standards track protocol for the
 +
Internet community, and requests discussion and suggestions for
 +
improvements.  Please refer to the current edition of the "Internet
 +
Official Protocol Standards" ([[STD1|STD 1]]) for the standardization state
 +
and status of this protocol.  Distribution of this memo is unlimited.
  
 +
'''Copyright Notice'''
  
 +
Copyright (C) The Internet Society (2003).  All Rights Reserved.
  
Network Working Group                                    C.M. Heard, Ed.Request for Comments: 3637                                    ConsultantCategory: Standards Track                                September 2003
+
'''Abstract'''
 
 
                  Definitions of Managed Objects            for the Ethernet WAN Interface Sublayer
 
Status of this Memo
 
This document specifies an Internet standards track protocol for theInternet community, and requests discussion and suggestions forimprovements.  Please refer to the current edition of the "InternetOfficial Protocol Standards" (STD 1) for the standardization stateand status of this protocol.  Distribution of this memo is unlimited.
 
Copyright Notice
 
Copyright (C) The Internet Society (2003).  All Rights Reserved.
 
Abstract
 
  
 
This document defines a portion of the Management Information Base
 
This document defines a portion of the Management Information Base
Line 24: Line 30:
 
Ethernet-like Interface MIB, the 802.3 Medium Attachment Unit MIB,
 
Ethernet-like Interface MIB, the 802.3 Medium Attachment Unit MIB,
 
the Interfaces Group MIB, and the Inverted Stack Table MIB.
 
the Interfaces Group MIB, and the Inverted Stack Table MIB.
 +
 +
          3.4.2.  Use of ifTable for LLC Layer/MAC Layer
 +
                  Reconciliation Sublayer/Physical Coding Sublayer  5
 +
 +
          3.4.4.  Use of ifTable for SONET/SDH Medium/Section/
 +
 +
    3.7.  Mapping of SNMP Objects to WIS Station Management
 +
 +
Appendix A: Collection of Performance Data Using WIS
  
 
== Conventions ==
 
== Conventions ==
Line 30: Line 45:
 
"SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
 
"SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
 
"OPTIONAL", when they appear in this document, are to be interpreted
 
"OPTIONAL", when they appear in this document, are to be interpreted
as described in [[BCP14|BCP 14]], [[RFC2119|RFC 2119]] [RFC2119].
+
as described in [[BCP14|BCP 14]], [[RFC2119|RFC 2119]] [[RFC2119]].
  
 
== The Internet-Standard Management Framework ==
 
== The Internet-Standard Management Framework ==
Line 36: Line 51:
 
For a detailed overview of the documents that describe the current
 
For a detailed overview of the documents that describe the current
 
Internet-Standard Management Framework, please refer to section 7 of
 
Internet-Standard Management Framework, please refer to section 7 of
[[RFC3410|RFC 3410]] [RFC3410].
+
[[RFC3410|RFC 3410]] [[RFC3410]].
  
 
Managed objects are accessed via a virtual information store, termed
 
Managed objects are accessed via a virtual information store, termed
Line 43: Line 58:
 
Objects in the MIB are defined using the mechanisms defined in the
 
Objects in the MIB are defined using the mechanisms defined in the
 
Structure of Management Information (SMI).  This memo specifies a MIB
 
Structure of Management Information (SMI).  This memo specifies a MIB
module that is compliant to the SMIv2, which is described in STD 58,
+
module that is compliant to the SMIv2, which is described in [[STD58|STD 58]],
[[RFC2578|RFC 2578]] [RFC2578], STD 58, [[RFC2579|RFC 2579]] [RFC2579] and STD 58, [[RFC2580|RFC 2580]]
+
[[RFC2578|RFC 2578]] [[RFC2578]], [[STD58|STD 58]], [[RFC2579|RFC 2579]] [[RFC2579]] and [[STD58|STD 58]], [[RFC2580|RFC 2580]]
[RFC2580].
+
[[RFC2580]].
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
== Overview ==
 
== Overview ==
  
 
The objects defined in this memo are used in conjunction with objects
 
The objects defined in this memo are used in conjunction with objects
defined in the Interfaces Group MIB [RFC2863], the SONET/SDH
+
defined in the Interfaces Group MIB [[RFC2863]], the SONET/SDH
Interface MIB [RFC3592], and the 802.3 MAU MIB [RFC3636] to manage
+
Interface MIB [[RFC3592]], and the 802.3 MAU MIB [[RFC3636]] to manage
 
the Ethernet Wide Area Network (WAN) Interface Sublayer (WIS) defined
 
the Ethernet Wide Area Network (WAN) Interface Sublayer (WIS) defined
 
in [802.3ae].  The WIS contains functions to perform OC-192c/VC-4-64c
 
in [802.3ae].  The WIS contains functions to perform OC-192c/VC-4-64c
Line 93: Line 99:
 
compatible, information similar to that provided by most of the
 
compatible, information similar to that provided by most of the
 
members of the oWIS managed object class is available from objects
 
members of the oWIS managed object class is available from objects
defined in the SONET-MIB [RFC3592].  Thus, the MIB module defined in
+
defined in the SONET-MIB [[RFC3592]].  Thus, the MIB module defined in
 
this memo is a sparse augmentation of the SONET-MIB -- in other
 
this memo is a sparse augmentation of the SONET-MIB -- in other
 
words, every table defined here is an extension of some table in the
 
words, every table defined here is an extension of some table in the
Line 104: Line 110:
 
from the SONET-MIB -- specifically, the threshold objects and
 
from the SONET-MIB -- specifically, the threshold objects and
 
interval counter objects -- provide only approximate representations
 
interval counter objects -- provide only approximate representations
 
 
 
 
  
 
of the corresponding oWIS attributes, as detailed in Section 3.6.  An
 
of the corresponding oWIS attributes, as detailed in Section 3.6.  An
Line 129: Line 131:
  
 
Support for the mauModIfCompl3 compliance statement of the MAU-MIB
 
Support for the mauModIfCompl3 compliance statement of the MAU-MIB
[RFC3636] is REQUIRED for all Ethernet-like interfaces.  The MAU-MIB
+
[[RFC3636]] is REQUIRED for all Ethernet-like interfaces.  The MAU-MIB
 
is needed in order to allow applications to control and/or determine
 
is needed in order to allow applications to control and/or determine
 
the media type in use.  That is important for devices than can
 
the media type in use.  That is important for devices than can
Line 140: Line 142:
 
=== Use of the ifTable ===
 
=== Use of the ifTable ===
  
This section specifies how the ifTable, as defined in [RFC2863], is
+
This section specifies how the ifTable, as defined in [[RFC2863]], is
 
used for the Ethernet WIS application.
 
used for the Ethernet WIS application.
  
 +
==== Layering Model ====
  
 +
Ethernet interfaces that employ the WIS are layered as defined in
 +
[802.3ae].  The corresponding use of the ifTable [[RFC2863]] is shown
 +
in the figure below.
  
 
+
       _____________________________  _
 
+
       |    LLC Layer                |  |
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
==== Layering Model ====
 
 
 
Ethernet interfaces that employ the WIS are layered as defined in
 
[802.3ae].  The corresponding use of the ifTable [RFC2863] is shown
 
in the figure below.
 
 
 
       _____________________________  _
 
       |    LLC Layer                |  |
 
 
       +-----------------------------+  |
 
       +-----------------------------+  |
 
       |    MAC Layer                |  |
 
       |    MAC Layer                |  |
Line 189: Line 172:
  
 
The exact configuration and multiplexing of the layers is maintained
 
The exact configuration and multiplexing of the layers is maintained
in the ifStackTable [RFC2863] and in the ifInvStackTable [RFC2864].
+
in the ifStackTable [[RFC2863]] and in the ifInvStackTable [[RFC2864]].
  
 
==== Use of ifTable for LLC Layer/MAC Layer/Reconciliation ====
 
==== Use of ifTable for LLC Layer/MAC Layer/Reconciliation ====
 
       Sublayer/Physical Coding Sublayer
 
       Sublayer/Physical Coding Sublayer
  
The ifTable MUST be used as specified in [RFC3635] and [RFC3636] for
+
The ifTable MUST be used as specified in [[RFC3635]] and [[RFC3636]] for
 
the LLC Layer/MAC Layer/Reconciliation Sublayer/Physical Coding
 
the LLC Layer/MAC Layer/Reconciliation Sublayer/Physical Coding
 
Sublayer.
 
Sublayer.
Line 200: Line 183:
 
==== Use of ifTable for SONET/SDH Path Layer ====
 
==== Use of ifTable for SONET/SDH Path Layer ====
  
The ifTable MUST be used as specified in [RFC3592] for the SONET/SDH
+
The ifTable MUST be used as specified in [[RFC3592]] for the SONET/SDH
 
Path Layer.  The value of ifHighSpeed is set to 9585.  ifSpeed
 
Path Layer.  The value of ifHighSpeed is set to 9585.  ifSpeed
 
reports a value of 4294967295.
 
reports a value of 4294967295.
Line 206: Line 189:
 
==== Use of ifTable for SONET/SDH Medium/Section/Line Layer ====
 
==== Use of ifTable for SONET/SDH Medium/Section/Line Layer ====
  
The ifTable MUST be used as specified in [RFC3592] for the SONET/SDH
+
The ifTable MUST be used as specified in [[RFC3592]] for the SONET/SDH
 
Medium/Section/Line Layer.  The value of ifHighSpeed is set to 9953.
 
Medium/Section/Line Layer.  The value of ifHighSpeed is set to 9953.
 
ifSpeed reports a value of 4294967295.
 
ifSpeed reports a value of 4294967295.
 
 
 
 
 
  
 
=== SONET/SDH Terminology ===
 
=== SONET/SDH Terminology ===
  
 
The SONET/SDH terminology used in [802.3ae] is mostly the same as in
 
The SONET/SDH terminology used in [802.3ae] is mostly the same as in
[RFC3592], but there are a few differences.  In those cases the
+
[[RFC3592]], but there are a few differences.  In those cases the
 
definitions in [802.3ae] take precedence.  The specific differences
 
definitions in [802.3ae] take precedence.  The specific differences
 
are as follows.
 
are as follows.
Line 231: Line 209:
 
     It is reported by setting both the sonetPathSignalLabelMismatch
 
     It is reported by setting both the sonetPathSignalLabelMismatch
 
     bit in the appropriate instance of sonetPathCurrentStatus
 
     bit in the appropriate instance of sonetPathCurrentStatus
     (defined in [RFC3592]) and the etherWisPathPLM bit in the
+
     (defined in [[RFC3592]]) and the etherWisPathPLM bit in the
 
     corresponding instance of etherWisPathCurrentStatus (defined
 
     corresponding instance of etherWisPathCurrentStatus (defined
 
     below).
 
     below).
Line 239: Line 217:
 
     occurring when the Physical Coding Sublayer is unable to locate
 
     occurring when the Physical Coding Sublayer is unable to locate
 
     64B/66B code group boundaries.  There is no analogous defect
 
     64B/66B code group boundaries.  There is no analogous defect
     defined in [RFC3592].  It is reported by setting the
+
     defined in [[RFC3592]].  It is reported by setting the
 
     etherWisPathLCD bit in the appropriate instance of the object
 
     etherWisPathLCD bit in the appropriate instance of the object
 
     etherWisPathCurrentStatus defined below.
 
     etherWisPathCurrentStatus defined below.
Line 248: Line 226:
 
     defects (triggered by path AIS or path LOP) and remote payload
 
     defects (triggered by path AIS or path LOP) and remote payload
 
     defects (triggered by Payload Label Mismatch or Loss of Codegroup
 
     defects (triggered by Payload Label Mismatch or Loss of Codegroup
     Delineation).  [RFC3592] defines the one-bit RDI-P (Remote Defect
+
     Delineation).  [[RFC3592]] defines the one-bit RDI-P (Remote Defect
 
     Indication - Path), which signals remote server detects (i.e.,
 
     Indication - Path), which signals remote server detects (i.e.,
 
     path AIS and path LOP) only.  An implementation of the MIB module
 
     path AIS and path LOP) only.  An implementation of the MIB module
Line 256: Line 234:
 
     ERDI-P payload defects and ERDI-P server defects are reported in
 
     ERDI-P payload defects and ERDI-P server defects are reported in
 
     the object etherWisFarEndPathCurrentStatus defined below.
 
     the object etherWisFarEndPathCurrentStatus defined below.
 
 
 
 
 
 
 
 
 
 
 
  
 
Path Coding Violations
 
Path Coding Violations
Line 280: Line 247:
 
This section contains the mapping between oWIS managed objects
 
This section contains the mapping between oWIS managed objects
 
defined in [802.3ae] and managed objects defined in this document and
 
defined in [802.3ae] and managed objects defined in this document and
in associated MIB modules, i.e., the IF-MIB [RFC2863], the SONET-MIB
+
in associated MIB modules, i.e., the IF-MIB [[RFC2863]], the SONET-MIB
[RFC3592], and the MAU-MIB [RFC3636].
+
[[RFC3592]], and the MAU-MIB [[RFC3636]].
  
 
IEEE 802.3 Managed Object    Corresponding SNMP Object
 
IEEE 802.3 Managed Object    Corresponding SNMP Object
Line 316: Line 283:
 
                                         sonetFarEndLineIntervalESs
 
                                         sonetFarEndLineIntervalESs
 
  aFarEndLineCVs              SONET-MIB - sonetFarEndLineCurrentCVs +
 
  aFarEndLineCVs              SONET-MIB - sonetFarEndLineCurrentCVs +
 
 
 
 
  
 
                                         sonetFarEndLineIntervalCVs
 
                                         sonetFarEndLineIntervalCVs
Line 343: Line 306:
  
 
IEEE 802.3 Managed Object    How Corresponding SNMP Object Differs
 
IEEE 802.3 Managed Object    How Corresponding SNMP Object Differs
 
  
 
aSectionSESThreshold      This object is defined in [802.3ae] as an
 
aSectionSESThreshold      This object is defined in [802.3ae] as an
Line 364: Line 326:
 
                           sonetSectionIntervalESs are 15-minute
 
                           sonetSectionIntervalESs are 15-minute
 
                           interval counters.
 
                           interval counters.
 
 
 
 
 
 
 
 
 
  
 
aSectionSEFSs            This object is defined as a generalized
 
aSectionSEFSs            This object is defined as a generalized
Line 423: Line 376:
 
                           sonetLineIntervalCVs are 15-minute interval
 
                           sonetLineIntervalCVs are 15-minute interval
  
 
+
                           counters, and they are inhibited (not
 
 
 
 
 
 
                           counters, and they are inhibited (not
 
 
                           incremented) during one-second intervals
 
                           incremented) during one-second intervals
 
                           that qualify either as severely errored
 
                           that qualify either as severely errored
Line 475: Line 424:
 
                           sonetPathCurrentSESs and
 
                           sonetPathCurrentSESs and
 
                           sonetPathIntervalSESs are 15-minute
 
                           sonetPathIntervalSESs are 15-minute
 
 
 
 
  
 
                           interval counters, and they are inhibited
 
                           interval counters, and they are inhibited
Line 486: Line 431:
 
                           PLM-P and LCD-P defects in the criteria for
 
                           PLM-P and LCD-P defects in the criteria for
 
                           declaring path layer severely errored
 
                           declaring path layer severely errored
                           seconds, while [RFC3592] does not.
+
                           seconds, while [[RFC3592]] does not.
  
 
aPathESs                  This object is defined as a generalized
 
aPathESs                  This object is defined as a generalized
Line 498: Line 443:
 
                           addition, [802.3ae] includes PLM-P and
 
                           addition, [802.3ae] includes PLM-P and
 
                           LCD-P defects in the criteria for declaring
 
                           LCD-P defects in the criteria for declaring
                           path layer errored seconds, while [RFC3592]
+
                           path layer errored seconds, while [[RFC3592]]
 
                           does not.
 
                           does not.
  
Line 522: Line 467:
 
                           far-end PLM-P and LCD-P defects in the
 
                           far-end PLM-P and LCD-P defects in the
 
                           criteria for declaring far-end path layer
 
                           criteria for declaring far-end path layer
                           severely errored seconds, while [RFC3592]
+
                           severely errored seconds, while [[RFC3592]]
 
                           does not.
 
                           does not.
  
Line 528: Line 473:
 
                           nonresetable counter in [802.3ae], and it
 
                           nonresetable counter in [802.3ae], and it
 
                           is not subject to inhibiting.  The objects
 
                           is not subject to inhibiting.  The objects
 
 
 
 
  
 
                           sonetFarEndPathCurrentESs and
 
                           sonetFarEndPathCurrentESs and
Line 541: Line 482:
 
                           far-end PLM-P and LCD-P defects in the
 
                           far-end PLM-P and LCD-P defects in the
 
                           criteria for declaring far-end path layer
 
                           criteria for declaring far-end path layer
                           errored seconds, while [RFC3592] does not.
+
                           errored seconds, while [[RFC3592]] does not.
  
 
aFarEndPathCVs            This object is defined as a generalized
 
aFarEndPathCVs            This object is defined as a generalized
Line 553: Line 494:
 
                           errored seconds or as unavailable seconds.
 
                           errored seconds or as unavailable seconds.
  
'''Note:''' despite the semantic differences between the threshold objects
+
Note:  despite the semantic differences between the threshold objects
 
and counter objects imported from the SONET-MIB and the corresponding
 
and counter objects imported from the SONET-MIB and the corresponding
 
IEEE 802.3 objects, the hardware support mandated by [802.3ae]
 
IEEE 802.3 objects, the hardware support mandated by [802.3ae]
Line 561: Line 502:
  
 
Some of the objects defined in this memo or incorporated by reference
 
Some of the objects defined in this memo or incorporated by reference
from the SONET-MIB [RFC3592] or the MAU-MIB [RFC3636] require
+
from the SONET-MIB [[RFC3592]] or the MAU-MIB [[RFC3636]] require
 
WIS-specific hardware support.  [802.3ae] subclause 50.3.11 specifies
 
WIS-specific hardware support.  [802.3ae] subclause 50.3.11 specifies
 
WIS management interface requirements, including a required subset of
 
WIS management interface requirements, including a required subset of
Line 581: Line 522:
 
SONET-MIB - sonetMediumType                    none required
 
SONET-MIB - sonetMediumType                    none required
 
SONET-MIB - sonetMediumTimeElapsed              none required
 
SONET-MIB - sonetMediumTimeElapsed              none required
 
 
 
 
  
 
SONET-MIB - sonetMediumValidIntervals          none required
 
SONET-MIB - sonetMediumValidIntervals          none required
Line 634: Line 571:
 
SONET-MIB - sonetPathCurrentWidth              none required
 
SONET-MIB - sonetPathCurrentWidth              none required
 
SONET-MIB - sonetPathCurrentStatus              10G WIS status 3
 
SONET-MIB - sonetPathCurrentStatus              10G WIS status 3
 
 
 
 
  
 
SONET-MIB - sonetPathCurrentESs                \
 
SONET-MIB - sonetPathCurrentESs                \
Line 684: Line 617:
 
mandatory and optional WIS test features specified in [802.3ae]
 
mandatory and optional WIS test features specified in [802.3ae]
 
subclause 50.3.8.
 
subclause 50.3.8.
 
 
 
 
 
 
 
  
 
The etherWisDeviceTable is a sparse augmentation of the
 
The etherWisDeviceTable is a sparse augmentation of the
Line 735: Line 661:
 
entry in the sonetFarEndPathCurrentTable and the same ifIndex value
 
entry in the sonetFarEndPathCurrentTable and the same ifIndex value
 
MUST be used for both entries.
 
MUST be used for both entries.
 
 
 
 
 
 
 
 
 
  
 
== Object Definitions ==
 
== Object Definitions ==
Line 793: Line 710:
 
               Tel: +1 650-964-8391
 
               Tel: +1 650-964-8391
 
             E-mail: [email protected]"
 
             E-mail: [email protected]"
 
 
 
 
  
 
     DESCRIPTION
 
     DESCRIPTION
Line 841: Line 754:
  
 
etherWisConformance OBJECT IDENTIFIER ::= { etherWisMIB 3 }
 
etherWisConformance OBJECT IDENTIFIER ::= { etherWisMIB 3 }
 
 
 
 
 
 
 
 
 
  
 
-- groups in the Ethernet WIS MIB module
 
-- groups in the Ethernet WIS MIB module
Line 860: Line 764:
  
 
etherWisFarEndPath  OBJECT IDENTIFIER ::= { etherWisObjectsPath 2 }
 
etherWisFarEndPath  OBJECT IDENTIFIER ::= { etherWisObjectsPath 2 }
 
  
 
-- The Device group
 
-- The Device group
Line 893: Line 796:
 
         }
 
         }
  
 
+
etherWisDeviceTxTestPatternMode OBJECT-TYPE
 
+
     SYNTAX  INTEGER {
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
etherWisDeviceTxTestPatternMode OBJECT-TYPE
 
     SYNTAX  INTEGER {
 
 
                 none(1),
 
                 none(1),
 
                 squareWave(2),
 
                 squareWave(2),
Line 945: Line 837:
 
     MAX-ACCESS  read-write
 
     MAX-ACCESS  read-write
 
     STATUS  current
 
     STATUS  current
 
 
 
 
 
 
 
 
 
 
 
  
 
     DESCRIPTION
 
     DESCRIPTION
Line 1,000: Line 881:
 
     ::= { etherWisDeviceEntry 3 }
 
     ::= { etherWisDeviceEntry 3 }
  
 +
-- The Section group
  
 +
-- These objects provide WIS extensions to
 +
-- the SONET-MIB Section Group.
  
 
+
etherWisSectionCurrentTable OBJECT-TYPE
 
 
 
 
 
 
 
 
 
 
 
 
 
 
-- The Section group
 
 
 
-- These objects provide WIS extensions to
 
-- the SONET-MIB Section Group.
 
 
 
etherWisSectionCurrentTable OBJECT-TYPE
 
 
     SYNTAX  SEQUENCE OF EtherWisSectionCurrentEntry
 
     SYNTAX  SEQUENCE OF EtherWisSectionCurrentEntry
 
     MAX-ACCESS  not-accessible
 
     MAX-ACCESS  not-accessible
Line 1,055: Line 926:
 
       "[IEEE 802.3 Std.], 30.8.1.1.8, aJ0ValueTX."
 
       "[IEEE 802.3 Std.], 30.8.1.1.8, aJ0ValueTX."
 
     ::= { etherWisSectionCurrentEntry 1 }
 
     ::= { etherWisSectionCurrentEntry 1 }
 
 
 
 
 
 
 
  
 
etherWisSectionCurrentJ0Received OBJECT-TYPE
 
etherWisSectionCurrentJ0Received OBJECT-TYPE
Line 1,073: Line 937:
 
       "[IEEE 802.3 Std.], 30.8.1.1.9, aJ0ValueRX."
 
       "[IEEE 802.3 Std.], 30.8.1.1.9, aJ0ValueRX."
 
     ::= { etherWisSectionCurrentEntry 2 }
 
     ::= { etherWisSectionCurrentEntry 2 }
 
  
 
-- The Path group
 
-- The Path group
Line 1,106: Line 969:
 
         }
 
         }
  
 
+
etherWisPathCurrentStatus OBJECT-TYPE
 
+
     SYNTAX  BITS {
 
+
                 etherWisPathLOP(0),
 
 
 
 
 
 
 
 
 
 
 
 
 
 
etherWisPathCurrentStatus OBJECT-TYPE
 
     SYNTAX  BITS {
 
                 etherWisPathLOP(0),
 
 
                 etherWisPathAIS(1),
 
                 etherWisPathAIS(1),
 
                 etherWisPathPLM(2),
 
                 etherWisPathPLM(2),
Line 1,154: Line 1,007:
 
           MUST be set in the corresponding instance of
 
           MUST be set in the corresponding instance of
 
           sonetPathCurrentStatus.
 
           sonetPathCurrentStatus.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
       etherWisPathLCD(3)
 
       etherWisPathLCD(3)
Line 1,207: Line 1,046:
 
     ::= { etherWisPathCurrentEntry 3 }
 
     ::= { etherWisPathCurrentEntry 3 }
  
 +
-- The Far End Path group
  
 
+
-- These objects provide WIS extensions to
 
+
-- the SONET-MIB Far End Path Group.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
-- The Far End Path group
 
 
 
-- These objects provide WIS extensions to
 
-- the SONET-MIB Far End Path Group.
 
  
 
etherWisFarEndPathCurrentTable OBJECT-TYPE
 
etherWisFarEndPathCurrentTable OBJECT-TYPE
Line 1,269: Line 1,093:
 
           PLM-P or LCD-P) is currently being signaled
 
           PLM-P or LCD-P) is currently being signaled
 
           in G1 bits 5-7.
 
           in G1 bits 5-7.
 
 
 
 
 
  
 
       etherWisFarEndServerDefect(1)
 
       etherWisFarEndServerDefect(1)
Line 1,284: Line 1,103:
 
       "[IEEE 802.3 Std.], 30.8.1.1.25, aFarEndPathStatus."
 
       "[IEEE 802.3 Std.], 30.8.1.1.25, aFarEndPathStatus."
 
     ::= { etherWisFarEndPathCurrentEntry 1 }
 
     ::= { etherWisFarEndPathCurrentEntry 1 }
 
  
 
--
 
--
Line 1,317: Line 1,135:
 
     ::= { etherWisGroups 2 }
 
     ::= { etherWisGroups 2 }
  
 
+
etherWisSectionGroup OBJECT-GROUP
 
+
     OBJECTS {
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
etherWisSectionGroup OBJECT-GROUP
 
     OBJECTS {
 
 
         etherWisSectionCurrentJ0Transmitted,
 
         etherWisSectionCurrentJ0Transmitted,
 
         etherWisSectionCurrentJ0Received
 
         etherWisSectionCurrentJ0Received
Line 1,376: Line 1,183:
 
       EtherLike-MIB          dot3Compliance2
 
       EtherLike-MIB          dot3Compliance2
 
       MAU-MIB                mauModIfCompl3"
 
       MAU-MIB                mauModIfCompl3"
 
 
 
 
  
 
     MODULE  -- this module
 
     MODULE  -- this module
Line 1,422: Line 1,225:
 
             allow values other than zero to be
 
             allow values other than zero to be
 
             written to this object."
 
             written to this object."
 
 
 
 
 
 
 
 
 
 
 
  
 
     MODULE SONET-MIB
 
     MODULE SONET-MIB
Line 1,481: Line 1,273:
 
             "Write access is not required, nor is support for values
 
             "Write access is not required, nor is support for values
 
             other than sonetNoLoop(0) and sonetFacilityLoop(1)."
 
             other than sonetNoLoop(0) and sonetFacilityLoop(1)."
 
 
 
 
 
  
 
         OBJECT      sonetSESthresholdSet
 
         OBJECT      sonetSESthresholdSet
Line 1,533: Line 1,320:
 
Groups.  It builds upon the work of the IEEE P802.3ae 10 Gigabit
 
Groups.  It builds upon the work of the IEEE P802.3ae 10 Gigabit
 
Ethernet Task Force.
 
Ethernet Task Force.
 
 
 
 
 
 
  
 
== Security Considerations ==
 
== Security Considerations ==
Line 1,577: Line 1,358:
  
 
It is RECOMMENDED that implementers consider the security features as
 
It is RECOMMENDED that implementers consider the security features as
provided by the SNMPv3 framework (see [RFC3410], section 8),
+
provided by the SNMPv3 framework (see [[RFC3410]], section 8),
 
including full support for the SNMPv3 cryptographic mechanisms (for
 
including full support for the SNMPv3 cryptographic mechanisms (for
 
authentication and privacy).
 
authentication and privacy).
Line 1,588: Line 1,369:
 
the objects only to those principals (users) that have legitimate
 
the objects only to those principals (users) that have legitimate
 
rights to indeed GET or SET (change/create/delete) them.
 
rights to indeed GET or SET (change/create/delete) them.
 
 
 
 
  
 
== References ==
 
== References ==
Line 1,597: Line 1,374:
 
=== Normative References ===
 
=== Normative References ===
  
[RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate           Requirements Levels", [[BCP14|BCP 14]], [[RFC2119|RFC 2119]], March 1997.
+
[[RFC2119]]  Bradner, S., "Key words for use in RFCs to Indicate
[RFC2578]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,           Rose, M. and S. Waldbusser, "Structure of Management           Information Version 2 (SMIv2)", STD 58, [[RFC2578|RFC 2578]], April            1999.
+
            Requirements Levels", [[BCP14|BCP 14]], [[RFC2119|RFC 2119]], March 1997.
[RFC2579]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,            Rose, M. and S. Waldbusser, "Textual Conventions for            SMIv2", STD 58, [[RFC2579|RFC 2579]], April 1999.
+
 
[RFC2580]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,            Rose, M. and S. Waldbusser, "Conformance Statements for            SMIv2", STD 58, [[RFC2580|RFC 2580]], April 1999.
+
[[RFC2578]]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
[RFC2863]  McCloghrie, K. and F. Kastenholz, "The Interfaces Group            MIB", [[RFC2863|RFC 2863]], June 2000.
+
            Rose, M. and S. Waldbusser, "Structure of Management
[RFC2864]  McCloghrie, K. and G. Hanson, "The Inverted Stack Table            Extension to the Interfaces Group MIB", [[RFC2864|RFC 2864]], June            2000.
+
            Information Version 2 (SMIv2)", [[STD58|STD 58]], [[RFC2578|RFC 2578]], April
[RFC3592]  Tesink, K., "Definitions of Managed Objects for the            Synchronous Optical Network/Synchronous Digital Hierarchy            (SONET/SDH) Interface Type", [[RFC3592|RFC 3592]], September 2003.
+
            1999.
[T1.231]    American National Standard for Telecommunications -            Digital Hierarchy - Layer 1 In-Service Digital            Transmission Performance Monitoring, ANSI T1.231-1997,            September 1997.
 
[RFC3635]  Flick, J., "Definitions of Managed Objects for the            Ethernet-like Interface Types", [[RFC3635|RFC 3635]], September 2003.
 
[RFC3636]  Flick, J., "Definitions of Managed Objects for IEEE 802.3            Medium Attachment Units (MAUs)", [[RFC3636|RFC 3636]], September            2003.
 
  
 +
[[RFC2579]]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
 +
            Rose, M. and S. Waldbusser, "Textual Conventions for
 +
            SMIv2", [[STD58|STD 58]], [[RFC2579|RFC 2579]], April 1999.
  
 +
[[RFC2580]]  McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,
 +
            Rose, M. and S. Waldbusser, "Conformance Statements for
 +
            SMIv2", [[STD58|STD 58]], [[RFC2580|RFC 2580]], April 1999.
  
 +
[[RFC2863]]  McCloghrie, K. and F. Kastenholz, "The Interfaces Group
 +
            MIB", [[RFC2863|RFC 2863]], June 2000.
  
 +
[[RFC2864]]  McCloghrie, K. and G. Hanson, "The Inverted Stack Table
 +
            Extension to the Interfaces Group MIB", [[RFC2864|RFC 2864]], June
 +
            2000.
  
 +
[[RFC3592]]  Tesink, K., "Definitions of Managed Objects for the
 +
            Synchronous Optical Network/Synchronous Digital Hierarchy
 +
            (SONET/SDH) Interface Type", [[RFC3592|RFC 3592]], September 2003.
  
 +
[T1.231]    American National Standard for Telecommunications -
 +
            Digital Hierarchy - Layer 1 In-Service Digital
 +
            Transmission Performance Monitoring, ANSI T1.231-1997,
 +
            September 1997.
  
 +
[[RFC3635]]  Flick, J., "Definitions of Managed Objects for the
 +
            Ethernet-like Interface Types", [[RFC3635|RFC 3635]], September 2003.
  
 +
[[RFC3636]]  Flick, J., "Definitions of Managed Objects for IEEE 802.3
 +
            Medium Attachment Units (MAUs)", [[RFC3636|RFC 3636]], September
 +
            2003.
  
 +
[802.3ae]  Institute of Electrical and Electronic Engineers, IEEE
 +
            Std 802.3ae-2002, "IEEE Standard for Carrier Sense
 +
            Multiple Access with Collision Detection (CSMA/CD) Access
 +
            Method and Physical Layer Specifications - Media Access
 +
            Control (MAC) Parameters, Physical Layer and Management
 +
            Parameters for 10 Gb/s Operation", August 2002.
  
[802.3ae]  Institute of Electrical and Electronic Engineers, IEEE            Std 802.3ae-2002, "IEEE Standard for Carrier Sense            Multiple Access with Collision Detection (CSMA/CD) Access            Method and Physical Layer Specifications - Media Access            Control (MAC) Parameters, Physical Layer and Management            Parameters for 10 Gb/s Operation", August 2002.
 
 
=== Informative References ===
 
=== Informative References ===
  
[RFC3410]  Case, J., Mundy, R., Partain, D. and B. Stewart,           "Introduction and Applicability Statements for Internet-           Standard Management Framework", [[RFC3410|RFC 3410]], December 2002.
+
[[RFC3410]]  Case, J., Mundy, R., Partain, D. and B. Stewart,
 +
            "Introduction and Applicability Statements for Internet-
 +
            Standard Management Framework", [[RFC3410|RFC 3410]], December 2002.
  
 +
Appendix A:  Collection of Performance Data Using WIS MDIO Registers
  
 +
The purpose of this appendix is to illustrate how the WIS MDIO
 +
registers specified in [802.3ae] subclause 45.2.2 (and more
 +
specifically the subset required by [802.3ae] subclause 50.3.11) can
 +
be used to collect performance data either according to the
 +
conventions adopted by this document or according to the conventions
 +
specified in [802.3ae] Clause 30.
  
 +
For an agent implementing the SNMP managed objects required by this
 +
document the first step in collecting WIS performance data would be
 +
to poll the 10G WIS status 3 register and the various error count
 +
registers (10G WIS section BIP error count, 10G WIS line BIP errors,
 +
10G WIS far end line BIP errors, 10G WIS path block error count, and
 +
10G WIS far end path block error count) once per second.  The 10G WIS
 +
status 3 register bits are all latched until read and so would
 +
indicate whether a given defect occurred any time during the previous
 +
second.  The error count registers roll over modulo 2^16 or 2^32, and
 +
so to find the number of errors within the previous second the agent
 +
would need to subtract (modulo 2^16 or 2^32) the current reading from
 +
the reading taken one second ago.  Armed with that information, the
 +
agent could determine for any layer whether the one second interval
 +
was an errored second, a severely errored second (that requires
 +
comparison with a threshold unless a defect is present), or a
 +
severely errored frame second.  Determining whether a given second is
 +
or is not part of unavailable time requires additional logic;  the
 +
most straightforward and accurate method is the delay-line approach
 +
outlined in Appendix A of [[RFC3592]].  With that information available
 +
the agent would be able to determine by how much each current count
 +
should be incremented (including effects of inhibiting).
 +
Implementations that conform to [T1.231] would end each 15-minute
 +
interval on time-of-day clock 1/4 hour boundaries;  if the delay-line
 +
approach is used then a time-of-day timestamp would accompany the
 +
one-second statistics.  At the end of each interval the current
 +
registers would be pushed onto the history stack and then would be
 +
cleared.  The xyxIntervalValidData flags would be set to False(2) if
 +
the number of samples was not between 890 and 910 or, in the case of
 +
far-end counts, if a near-end defect occurred during the
 +
just-completed interval (see [T1.231] Section 9.1.2.2 for details).
  
 +
An agent implementing the [802.3ae] Clause 30 oWIS objects could also
 +
start by polling the 10G WIS status 3 register and the various error
 +
count registers to find the defects and error counts for the previous
 +
second, and it could determine the number of errors and whether the
 +
second was an errored second, a severely errored second, or a
 +
severely errored frame second in the same manner as above.  The rest
 +
of the process would simply be to increment the generalized non-
 +
resetable counters without consideration of any inhibiting rules.
  
 +
Contributors
  
 +
Mike Ayers
 +
1204 Knox Ave.
 +
San Jose, CA 95122
 +
USA
  
 +
Phone: +1 408 857 6810
 +
  
 +
John Flick
 +
Hewlett-Packard Company
 +
8000 Foothills Blvd.  M/S 5557
 +
Roseville, CA 95747-5557
 +
USA
  
 +
Phone: +1 916 785 4018
 +
Fax:  +1 916 785 1199
 +
  
 +
Kam Lam
 +
Lucent Technologies
 +
101 Crawfords Corner Road, Room 4C-616A
 +
Holmdel, NJ 07733
 +
USA
  
 +
Phone: +1 732 949 8338
 +
  
 +
Kerry McDonald
 +
Institute for Applied Supercomputing
 +
California State University San Bernardino
  
 +
 +
  
 +
K. C. Norseth
 +
L-3 Communications
 +
640 N. 2200 West.
 +
Salt Lake City, Utah 84116-0850
 +
USA
  
 +
Phone: +1 801 594 2809
 +
 +
  
 +
Kaj Tesink
 +
Telcordia Technologies
 +
331 Newman Springs Road
 +
P.O. Box 7020
 +
Red Bank, NJ  07701-7020
 +
USA
  
 +
Phone: +1 732 758 5254
 +
  
 +
Editor's Address
  
 +
C. M. Heard
 +
600 Rainbow Dr. #141
 +
Mountain View, CA 94041-2542
 +
USA
  
 +
Phone: +1 650 964 8391
 +
  
 +
Full Copyright Statement
  
 +
Copyright (C) The Internet Society (2003).  All Rights Reserved.
  
 
+
This document and translations of it may be copied and furnished to
 
+
others, and derivative works that comment on or otherwise explain it
 
+
or assist in its implementation may be prepared, copied, published
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Appendix A:  Collection of Performance Data Using WIS MDIO Registers
 
The purpose of this appendix is to illustrate how the WIS MDIOregisters specified in [802.3ae] subclause 45.2.2 (and morespecifically the subset required by [802.3ae] subclause 50.3.11) canbe used to collect performance data either according to theconventions adopted by this document or according to the conventionsspecified in [802.3ae] Clause 30.
 
For an agent implementing the SNMP managed objects required by thisdocument the first step in collecting WIS performance data would beto poll the 10G WIS status 3 register and the various error countregisters (10G WIS section BIP error count, 10G WIS line BIP errors,10G WIS far end line BIP errors, 10G WIS path block error count, and10G WIS far end path block error count) once per second.  The 10G WISstatus 3 register bits are all latched until read and so wouldindicate whether a given defect occurred any time during the previoussecond.  The error count registers roll over modulo 2^16 or 2^32, andso to find the number of errors within the previous second the agentwould need to subtract (modulo 2^16 or 2^32) the current reading fromthe reading taken one second ago.  Armed with that information, theagent could determine for any layer whether the one second intervalwas an errored second, a severely errored second (that requirescomparison with a threshold unless a defect is present), or aseverely errored frame second.  Determining whether a given second isor is not part of unavailable time requires additional logic;  themost straightforward and accurate method is the delay-line approachoutlined in Appendix A of [RFC3592].  With that information availablethe agent would be able to determine by how much each current countshould be incremented (including effects of inhibiting).Implementations that conform to [T1.231] would end each 15-minuteinterval on time-of-day clock 1/4 hour boundaries;  if the delay-lineapproach is used then a time-of-day timestamp would accompany theone-second statistics.  At the end of each interval the currentregisters would be pushed onto the history stack and then would becleared.  The xyxIntervalValidData flags would be set to False(2) ifthe number of samples was not between 890 and 910 or, in the case offar-end counts, if a near-end defect occurred during thejust-completed interval (see [T1.231] Section 9.1.2.2 for details).
 
An agent implementing the [802.3ae] Clause 30 oWIS objects could alsostart by polling the 10G WIS status 3 register and the various errorcount registers to find the defects and error counts for the previoussecond, and it could determine the number of errors and whether thesecond was an errored second, a severely errored second, or aseverely errored frame second in the same manner as above.  The restof the process would simply be to increment the generalized non-resetable counters without consideration of any inhibiting rules.
 
 
 
 
 
 
 
 
 
Contributors
 
Mike Ayers1204 Knox Ave.San Jose, CA 95122USA
 
Phone: +1 408 857 6810EMail: [email protected]
 
 
 
John FlickHewlett-Packard Company8000 Foothills Blvd.  M/S 5557Roseville, CA 95747-5557USA
 
Phone: +1 916 785 4018Fax:  +1 916 785 1199EMail: [email protected]
 
 
 
Kam LamLucent Technologies101 Crawfords Corner Road, Room 4C-616AHolmdel, NJ 07733USA
 
Phone: +1 732 949 8338EMail: [email protected]
 
 
 
Kerry McDonaldInstitute for Applied SupercomputingCalifornia State University San Bernardino
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
K. C. NorsethL-3 Communications640 N. 2200 West.Salt Lake City, Utah 84116-0850USA
 
Phone: +1 801 594 2809EMail: [email protected]      [email protected]
 
Kaj TesinkTelcordia Technologies331 Newman Springs RoadP.O. Box 7020Red Bank, NJ  07701-7020USA
 
Phone: +1 732 758 5254EMail: [email protected]
 
Editor's Address
 
C. M. Heard600 Rainbow Dr. #141Mountain View, CA 94041-2542USA
 
Phone: +1 650 964 8391EMail: [email protected]
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Full Copyright Statement
 
 
 
Copyright (C) The Internet Society (2003).  All Rights Reserved.
 
 
 
This document and translations of it may be copied and furnished to
 
others, and derivative works that comment on or otherwise explain it
 
or assist in its implementation may be prepared, copied, published
 
 
and distributed, in whole or in part, without restriction of any
 
and distributed, in whole or in part, without restriction of any
 
kind, provided that the above copyright notice and this paragraph are
 
kind, provided that the above copyright notice and this paragraph are
Line 1,757: Line 1,573:
 
Funding for the RFC Editor function is currently provided by the
 
Funding for the RFC Editor function is currently provided by the
 
Internet Society.
 
Internet Society.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
[[Category:Standards Track]]
 
[[Category:Standards Track]]

Latest revision as of 06:02, 4 October 2020

Network Working Group C.M. Heard, Ed. Request for Comments: 3637 Consultant Category: Standards Track September 2003

                 Definitions of Managed Objects
            for the Ethernet WAN Interface Sublayer

Status of this Memo

This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited.

Copyright Notice

Copyright (C) The Internet Society (2003). All Rights Reserved.

Abstract

This document defines a portion of the Management Information Base (MIB) for use with network management protocols in TCP/IP based internets. In particular, it defines objects for managing the Ethernet Wide Area Network (WAN) Interface Sublayer (WIS).

The MIB module defined in this memo is an extension of the Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH) Interface MIB and is implemented in conjunction with it and with the Ethernet-like Interface MIB, the 802.3 Medium Attachment Unit MIB, the Interfaces Group MIB, and the Inverted Stack Table MIB.

         3.4.2.  Use of ifTable for LLC Layer/MAC Layer
                 Reconciliation Sublayer/Physical Coding Sublayer  5
         3.4.4.  Use of ifTable for SONET/SDH Medium/Section/
   3.7.  Mapping of SNMP Objects to WIS Station Management

Appendix A: Collection of Performance Data Using WIS

Conventions

The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and "OPTIONAL", when they appear in this document, are to be interpreted as described in BCP 14, RFC 2119 RFC2119.

The Internet-Standard Management Framework

For a detailed overview of the documents that describe the current Internet-Standard Management Framework, please refer to section 7 of RFC 3410 RFC3410.

Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. MIB objects are generally accessed through the Simple Network Management Protocol (SNMP). Objects in the MIB are defined using the mechanisms defined in the Structure of Management Information (SMI). This memo specifies a MIB module that is compliant to the SMIv2, which is described in STD 58, RFC 2578 RFC2578, STD 58, RFC 2579 RFC2579 and STD 58, RFC 2580 RFC2580.

Overview

The objects defined in this memo are used in conjunction with objects defined in the Interfaces Group MIB RFC2863, the SONET/SDH Interface MIB RFC3592, and the 802.3 MAU MIB RFC3636 to manage the Ethernet Wide Area Network (WAN) Interface Sublayer (WIS) defined in [802.3ae]. The WIS contains functions to perform OC-192c/VC-4-64c framing and scrambling. It resides between the Physical Coding Sublayer (PCS) and the Physical Medium Attachment (PMA) sublayer within a 10GBASE-W 10 Gb/s WAN-compatible physical layer device (PHY) and may be used in conjunction with any of the PCS, PMA, and Physical Medium Dependent (PMD) sublayers defined in [802.3ae] for 10GBASE-W PHYs. Three types of 10GBASE-W PHYs are defined, distinguished by the type of optics employed: 10GBASE-SW, 10GBASE-LW, and 10GBASE-EW. The objects defined in this memo may be used to manage an Ethernet interface employing any type of 10GBASE-W PHY. They do not apply to any other kind of interface. In particular, they do not apply to so-called Ethernet Line Terminating Equipment (ELTE) residing within a SONET network element that uses the 10GBASE-W PMA/PMD sublayers but otherwise acts as SONET Line Terminating Equipment (LTE).

The objects presented here -- along with those incorporated by reference from the Interfaces Group MIB, the SONET/SDH Interface MIB, and the 802.3 MAU MIB -- are intended to provide exact representations of the mandatory attributes in the oWIS managed object class (i.e., the members of the pWISBasic package) defined in Clause 30 and Annex 30A of [802.3ae]. They are also intended to provide approximate representations of the optional attributes (i.e., the members of the pWISOptional package). Some objects with no analogues in oWIS are defined to support WIS testing features required by Clause 50 of [802.3ae].

Relationship to the SONET/SDH Interface MIB

Since the Ethernet WAN Interface Sublayer was designed to be SONET- compatible, information similar to that provided by most of the members of the oWIS managed object class is available from objects defined in the SONET-MIB RFC3592. Thus, the MIB module defined in this memo is a sparse augmentation of the SONET-MIB -- in other words, every table defined here is an extension of some table in the SONET-MIB -- and its compliance statement REQUIRES that an agent implementing the objects defined in this memo also implement the relevant SONET-MIB objects. That includes all objects required by sonetCompliance2 as well as some that it leaves optional.

It should be noted that some of the objects incorporated by reference from the SONET-MIB -- specifically, the threshold objects and interval counter objects -- provide only approximate representations

of the corresponding oWIS attributes, as detailed in Section 3.6. An alternative approach would have been to define new objects to exactly match the oWIS definitions. That approach was rejected because the SONET-MIB objects are already used in deployed systems to manage the SONET sublayers of ATM over SONET and PPP over SONET interfaces, and it was deemed undesirable to use a different scheme to manage the SONET sublayers of 10 Gb/s WAN-compatible Ethernet interfaces. Note that the approach adopted by this memo requires no hardware support beyond that mandated by [802.3ae] subclause 50.3.11.

Relationship to the Ethernet-like Interface MIB

An interface which includes the Ethernet WIS is, by definition, an Ethernet-like interface, and an agent implementing the objects defined in this memo MUST implement the objects required by the dot3Compliance2 compliance statement in the EtherLike-MIB.

Relationship to the 802.3 MAU MIB

Support for the mauModIfCompl3 compliance statement of the MAU-MIB RFC3636 is REQUIRED for all Ethernet-like interfaces. The MAU-MIB is needed in order to allow applications to control and/or determine the media type in use. That is important for devices than can support both the 10GBASE-R 10 Gb/s LAN format (which does not include the WIS) and the 10GBASE-W 10 Gb/s WAN format (which does include the WIS). The MAU-MIB also provides the means to put a device in standby mode or to reset it; the latter may be used to re-initialize the WIS.

Use of the ifTable

This section specifies how the ifTable, as defined in RFC2863, is used for the Ethernet WIS application.

Layering Model

Ethernet interfaces that employ the WIS are layered as defined in [802.3ae]. The corresponding use of the ifTable RFC2863 is shown in the figure below.

      _____________________________   _
     |    LLC Layer                |  |
     +-----------------------------+  |
     |    MAC Layer                |  |
     +-----------------------------+  > 1 ifEntry
     |    Reconciliation Sublayer  |  |   ifType: ethernetCsmacd(6)
     +-----------------------------+  |
     |    Physical Coding Sublayer |  |
     +-----------------------------+  +
     |    Path Layer               |  > 1 ifEntry
     +-----------------------------+  +   ifType: sonetPath(50)
     |    Line Layer               |  |
     +-----------------------------+  |
     |    Section Layer            |  > 1 ifEntry
     +-----------------------------+  |   ifType: sonet(39)
     |    Physical Medium Layer    |  |
      -----------------------------   -
  Figure 1 - Use of ifTable for an Ethernet WIS port

The exact configuration and multiplexing of the layers is maintained in the ifStackTable RFC2863 and in the ifInvStackTable RFC2864.

Use of ifTable for LLC Layer/MAC Layer/Reconciliation

     Sublayer/Physical Coding Sublayer

The ifTable MUST be used as specified in RFC3635 and RFC3636 for the LLC Layer/MAC Layer/Reconciliation Sublayer/Physical Coding Sublayer.

Use of ifTable for SONET/SDH Path Layer

The ifTable MUST be used as specified in RFC3592 for the SONET/SDH Path Layer. The value of ifHighSpeed is set to 9585. ifSpeed reports a value of 4294967295.

Use of ifTable for SONET/SDH Medium/Section/Line Layer

The ifTable MUST be used as specified in RFC3592 for the SONET/SDH Medium/Section/Line Layer. The value of ifHighSpeed is set to 9953. ifSpeed reports a value of 4294967295.

SONET/SDH Terminology

The SONET/SDH terminology used in [802.3ae] is mostly the same as in RFC3592, but there are a few differences. In those cases the definitions in [802.3ae] take precedence. The specific differences are as follows.

Unequipped

   This defect is not defined by [802.3ae].  An implementation that
   supports it SHOULD report it by setting the sonetPathUnequipped
   bit in the appropriate instance of sonetPathCurrentStatus.

Signal Label Mismatch

   This defect is called Payload Label Mismatch (PLM) in [802.3ae].
   It is reported by setting both the sonetPathSignalLabelMismatch
   bit in the appropriate instance of sonetPathCurrentStatus
   (defined in RFC3592) and the etherWisPathPLM bit in the
   corresponding instance of etherWisPathCurrentStatus (defined
   below).

Loss of Codegroup Delineation

   [802.3ae] defines Loss of Codegroup Delineation (LCD) as
   occurring when the Physical Coding Sublayer is unable to locate
   64B/66B code group boundaries.  There is no analogous defect
   defined in RFC3592.  It is reported by setting the
   etherWisPathLCD bit in the appropriate instance of the object
   etherWisPathCurrentStatus defined below.

STS-Path Remote Defect Indication

   [802.3ae] mandates the use of ERDI-P (Enhanced Remote Defect
   Indication - Path) defined in [T1.231] to signal remote server
   defects (triggered by path AIS or path LOP) and remote payload
   defects (triggered by Payload Label Mismatch or Loss of Codegroup
   Delineation).  RFC3592 defines the one-bit RDI-P (Remote Defect
   Indication - Path), which signals remote server detects (i.e.,
   path AIS and path LOP) only.  An implementation of the MIB module
   defined in this memo MUST set the sonetPathSTSRDI bit in the
   appropriate instance of sonetPathCurrentStatus when it receives
   an ERDI-P server defect indication from the remote end.  Both
   ERDI-P payload defects and ERDI-P server defects are reported in
   the object etherWisFarEndPathCurrentStatus defined below.

Path Coding Violations

   In [802.3ae] the path layer CV count is based on block errors and
   not BIP-8 errors, i.e., it is incremented only once for each B3
   byte that indicates incorrect parity, regardless of the number of
   bits in error.  Note that Section 8.4.5.1 of [T1.231] allows
   either path BIP-8 errors or path block errors to be used for the
   path layer error count.

Mapping of IEEE 802.3 Managed Objects

This section contains the mapping between oWIS managed objects defined in [802.3ae] and managed objects defined in this document and in associated MIB modules, i.e., the IF-MIB RFC2863, the SONET-MIB RFC3592, and the MAU-MIB RFC3636.

IEEE 802.3 Managed Object Corresponding SNMP Object

oWIS - pWISBasic package

aWISID                      IF-MIB - ifIndex
aSectionStatus              SONET-MIB - sonetSectionCurrentStatus
aLineStatus                 SONET-MIB - sonetLineCurrentStatus
aPathStatus                 etherWisPathCurrentStatus
aFarEndPathStatus           etherWisFarEndPathCurrentStatus

oWIS - pWISOptional package

aSectionSESThreshold        SONET-MIB - sonetSESthresholdSet
aSectionSESs                SONET-MIB - sonetSectionCurrentSESs +
                                        sonetSectionIntervalSESs
aSectionESs                 SONET-MIB - sonetSectionCurrentESs +
                                        sonetSectionIntervalESs
aSectionSEFSs               SONET-MIB - sonetSectionCurrentSEFSs +
                                        sonetSectionIntervalSEFSs
aSectionCVs                 SONET-MIB - sonetSectionCurrentCVs +
                                           sonetSectionIntervalCVs
aJ0ValueTX                  etherWisSectionCurrentJ0Transmitted
aJ0ValueRX                  etherWisSectionCurrentJ0Received
aLineSESThreshold           SONET-MIB - sonetSESthresholdSet
aLineSESs                   SONET-MIB - sonetLineCurrentSESs +
                                        sonetLineIntervalSESs
aLineESs                    SONET-MIB - sonetLineCurrentESs +
                                        sonetLineIntervalESs
aLineCVs                    SONET-MIB - sonetLineCurrentCVs +
                                        sonetLineIntervalCVs
aFarEndLineSESs             SONET-MIB - sonetFarEndLineCurrentSESs +
                                        sonetFarEndLineIntervalSESs
aFarEndLineESs              SONET-MIB - sonetFarEndLineCurrentESs +
                                        sonetFarEndLineIntervalESs
aFarEndLineCVs              SONET-MIB - sonetFarEndLineCurrentCVs +
                                        sonetFarEndLineIntervalCVs
aPathSESThreshold           SONET-MIB - sonetSESthresholdSet
aPathSESs                   SONET-MIB - sonetPathCurrentSESs +
                                        sonetPathIntervalSESs
aPathESs                    SONET-MIB - sonetPathCurrentESs +
                                        sonetPathIntervalESs
aPathCVs                    SONET-MIB - sonetPathCurrentCVs +
                                        sonetPathIntervalCVs
aJ1ValueTX                  etherWisPathCurrentJ1Transmitted
aJ1ValueRX                  etherWisPathCurrentJ1Received
aFarEndPathSESs             SONET-MIB - sonetFarEndPathCurrentSESs +
                                        sonetFarEndPathIntervalSESs
aFarEndPathESs              SONET-MIB - sonetFarEndPathCurrentESs +
                                        sonetFarEndPathIntervalESs
aFarEndPathCVs              SONET-MIB - sonetFarEndPathCurrentCVs +
                                        sonetFarEndPathIntervalCVs

It should be noted that the threshold and counter objects imported from the SONET-MIB are not completely equivalent to the corresponding IEEE 802.3 objects. The specific differences are as follows:

IEEE 802.3 Managed Object How Corresponding SNMP Object Differs

aSectionSESThreshold This object is defined in [802.3ae] as an

                         integer with one instance per interface.
                         sonetSESthresholdSet is an enumerated value
                         that has one instance per network element;
                         it controls the thresholds for all layers
                         simultaneously and allows only certain
                         discrete values to be selected.

aSectionSESs This object is defined in [802.3ae] as a

                         generalized nonresetable counter.  The
                         objects sonetSectionCurrentSESs and
                         sonetSectionIntervalSESs are 15-minute
                         interval counters.

aSectionESs This object is defined as a generalized

                         nonresetable counter in [802.3ae].  The
                         objects sonetSectionCurrentESs and
                         sonetSectionIntervalESs are 15-minute
                         interval counters.

aSectionSEFSs This object is defined as a generalized

                         nonresetable counter in [802.3ae].  The
                         objects sonetSectionCurrentSEFSs and
                         sonetSectionIntervalSEFSs are 15-minute
                         interval counters.

aSectionCVs This object is defined as a generalized

                         nonresetable counter in [802.3ae], and it
                         is not subject to inhibiting.  The objects
                         sonetSectionCurrentCVs and
                         sonetSectionIntervalCVs are 15-minute
                         interval counters, and they are inhibited
                         (not incremented) during one-second
                         intervals that qualify as severely errored
                         seconds.

aLineSESThreshold This object is defined in [802.3ae] as an

                         integer with one instance per interface.
                         sonetSESthresholdSet is an enumerated value
                         that has one instance per network element;
                         it controls the thresholds for all layers
                         simultaneously and allows only certain
                         discrete values to be selected.

aLineSESs This object is defined as a generalized

                         nonresetable counter in [802.3ae], and it
                         is not subject to inhibiting.  The objects
                         sonetLineCurrentSESs and
                         sonetLineIntervalSESs are 15-minute
                         interval counters, and they are inhibited
                         (not incremented) during one-second
                         intervals that qualify as unavailable
                         seconds.

aLineESs This object is defined as a generalized

                         nonresetable counter in [802.3ae], and it
                         is not subject to inhibiting.  The objects
                         sonetLineCurrentESs and
                         sonetLineIntervalESs are 15-minute interval
                         counters, and they are inhibited (not
                         incremented) during one-second intervals
                         that qualify as unavailable seconds.

aLineCVs This object is defined as a generalized

                         nonresetable counter in [802.3ae], and it
                         is not subject to inhibiting.  The objects
                         sonetLineCurrentCVs and
                         sonetLineIntervalCVs are 15-minute interval
                         counters, and they are inhibited (not
                         incremented) during one-second intervals
                         that qualify either as severely errored
                         seconds or as unavailable seconds.

aFarEndLineSESs This object is defined as a generalized

                         nonresetable counter in [802.3ae], and it
                         is not subject to inhibiting.  The objects
                         sonetFarEndLineCurrentSESs and
                         sonetFarEndLineIntervalSESs are 15-minute
                         interval counters, and they are inhibited
                         (not incremented) during one-second
                         intervals that qualify as unavailable
                         seconds.

aFarEndLineESs This object is defined as a generalized

                         nonresetable counter in [802.3ae], and it
                         is not subject to inhibiting.  The objects
                         sonetFarEndLineCurrentESs and
                         sonetFarEndLineIntervalESs are 15-minute
                         interval counters, and they are inhibited
                         (not incremented) during one-second
                         intervals that qualify as unavailable
                         seconds.

aFarEndLineCVs This object is defined as a generalized

                         nonresetable counter in [802.3ae], and it
                         is not subject to inhibiting.  The objects
                         sonetFarEndLineCurrentCVs and
                         sonetFarEndLineIntervalCVs are 15-minute
                         interval counters, and they are inhibited
                         (not incremented) during one-second
                         intervals that qualify either as severely
                         errored seconds or as unavailable seconds.

aPathSESThreshold This object is defined in [802.3ae] as an

                         integer with one instance per interface.
                         sonetSESthresholdSet is an enumerated value
                         that has one instance per network element;
                         it controls the thresholds for all layers
                         simultaneously and allows only certain
                         discrete values to be selected.

aPathSESs This object is defined as a generalized

                         nonresetable counter in [802.3ae], and it
                         is not subject to inhibiting.  The objects
                         sonetPathCurrentSESs and
                         sonetPathIntervalSESs are 15-minute
                         interval counters, and they are inhibited
                         (not incremented) during one-second
                         intervals that qualify as unavailable
                         seconds.  In addition, [802.3ae] includes
                         PLM-P and LCD-P defects in the criteria for
                         declaring path layer severely errored
                         seconds, while RFC3592 does not.

aPathESs This object is defined as a generalized

                         nonresetable counter in [802.3ae], and it
                         is not subject to inhibiting.  The objects
                         sonetPathCurrentESs and
                         sonetPathIntervalESs are 15-minute interval
                         counters, and they are inhibited (not
                         incremented) during one-second intervals
                         that qualify as unavailable seconds.  In
                         addition, [802.3ae] includes PLM-P and
                         LCD-P defects in the criteria for declaring
                         path layer errored seconds, while RFC3592
                         does not.

aPathCVs This object is defined as a generalized

                         nonresetable counter in [802.3ae], and it
                         is not subject to inhibiting.  The objects
                         sonetPathCurrentCVs and
                         sonetPathIntervalCVs are 15-minute interval
                         counters, and they are inhibited (not
                         incremented) during one-second intervals
                         that qualify either as severely errored
                         seconds or as unavailable seconds.

aFarEndPathSESs This object is defined as a generalized

                         nonresetable counter in [802.3ae], and it
                         is not subject to inhibiting.  The objects
                         sonetFarEndPathCurrentSESs and
                         sonetFarEndPathIntervalSESs are 15-minute
                         interval counters, and they are inhibited
                         (not incremented) during one-second
                         intervals that qualify as unavailable
                         seconds.  In addition, [802.3ae] includes
                         far-end PLM-P and LCD-P defects in the
                         criteria for declaring far-end path layer
                         severely errored seconds, while RFC3592
                         does not.

aFarEndPathESs This object is defined as a generalized

                         nonresetable counter in [802.3ae], and it
                         is not subject to inhibiting.  The objects
                         sonetFarEndPathCurrentESs and
                         sonetFarEndPathIntervalESs are 15-minute
                         interval counters, and they are inhibited
                         (not incremented) during one-second
                         intervals that qualify as unavailable
                         seconds.  In addition, [802.3ae] includes
                         far-end PLM-P and LCD-P defects in the
                         criteria for declaring far-end path layer
                         errored seconds, while RFC3592 does not.

aFarEndPathCVs This object is defined as a generalized

                         nonresetable counter in [802.3ae], and it
                         is not subject to inhibiting.  The objects
                         sonetFarEndPathCurrentCVs and
                         sonetFarEndPathIntervalCVs are 15-minute
                         interval counters, and they are inhibited
                         (not incremented) during one-second
                         intervals that qualify either as severely
                         errored seconds or as unavailable seconds.

Note: despite the semantic differences between the threshold objects and counter objects imported from the SONET-MIB and the corresponding IEEE 802.3 objects, the hardware support mandated by [802.3ae] subclause 50.3.11 suffices for both. See Appendix A for details.

Mapping of SNMP Objects to WIS Station Management Registers

Some of the objects defined in this memo or incorporated by reference from the SONET-MIB RFC3592 or the MAU-MIB RFC3636 require WIS-specific hardware support. [802.3ae] subclause 50.3.11 specifies WIS management interface requirements, including a required subset of the WIS Management Data Input/Output (MDIO) registers defined in [802.3ae] subclause 45.2.2. The table below provides a cross- reference between those managed objects and the WIS MDIO registers from the subset in [802.3ae] subclause 50.3.11 required to support them. Note that the MDIO interface is optional; however, if it is not implemented, then the capabilities of the required register subset must be provided by other means.

SNMP Object WIS MDIO Register(s)

ETHER-WIS - etherWisDeviceTxTestPatternMode 10G WIS control 2 ETHER-WIS - etherWisDeviceRxTestPatternMode 10G WIS control 2 ETHER-WIS - etherWisDeviceRxTestPatternErrors 10G WIS test pattern

                                                      error counter

SONET-MIB - sonetMediumType none required SONET-MIB - sonetMediumTimeElapsed none required

SONET-MIB - sonetMediumValidIntervals none required SONET-MIB - sonetMediumLineCoding none required SONET-MIB - sonetMediumLineType none required SONET-MIB - sonetMediumCircuitIdentifier none required SONET-MIB - sonetMediumInvalidIntervals none required SONET-MIB - sonetMediumLoopbackConfig none required SONET-MIB - sonetSESthresholdSet none required

ETHER-WIS - etherWisSectionCurrentJ0Transmitted 10G WIS J0 transmit ETHER-WIS - etherWisSectionCurrentJ0Received 10G WIS J0 receive

SONET-MIB - sonetSectionCurrentStatus 10G WIS status 3 SONET-MIB - sonetSectionCurrentESs \ SONET-MIB - sonetSectionCurrentSESs \ SONET-MIB - sonetSectionCurrentSEFSs | 10G WIS status 3 SONET-MIB - sonetSectionCurrentCVs | + SONET-MIB - sonetSectionIntervalESs | 10G WIS section SONET-MIB - sonetSectionIntervalSESs | BIP error count SONET-MIB - sonetSectionIntervalSEFSs / SONET-MIB - sonetSectionIntervalCVs / SONET-MIB - sonetSectionIntervalValidData none required

SONET-MIB - sonetLineCurrentStatus 10G WIS status 3 SONET-MIB - sonetLineCurrentESs \ SONET-MIB - sonetLineCurrentSESs \ SONET-MIB - sonetLineCurrentCVs | 10G WIS status 3 SONET-MIB - sonetLineCurrentUASs | + SONET-MIB - sonetLineIntervalESs | 10G WIS line SONET-MIB - sonetLineIntervalSESs | BIP errors SONET-MIB - sonetLineIntervalCVs / SONET-MIB - sonetLineIntervalUASs / SONET-MIB - sonetLineIntervalValidData none required

SONET-MIB - sonetFarEndLineCurrentESs \ SONET-MIB - sonetFarEndLineCurrentSESs \ SONET-MIB - sonetFarEndLineCurrentCVs | 10G WIS status 3 SONET-MIB - sonetFarEndLineCurrentUASs | + SONET-MIB - sonetFarEndLineIntervalESs | 10G WIS far end SONET-MIB - sonetFarEndLineIntervalSESs | line BIP errors SONET-MIB - sonetFarEndLineIntervalCVs / SONET-MIB - sonetFarEndLineIntervalUASs / SONET-MIB - sonetFarEndLineIntervalValidData 10G WIS status 3

ETHER-WIS - etherWisPathCurrentStatus 10G WIS status 3 ETHER-WIS - etherWisPathCurrentJ1Transmitted 10G WIS J1 transmit ETHER-WIS - etherWisPathCurrentJ1Received 10G WIS J1 receive SONET-MIB - sonetPathCurrentWidth none required SONET-MIB - sonetPathCurrentStatus 10G WIS status 3

SONET-MIB - sonetPathCurrentESs \ SONET-MIB - sonetPathCurrentSESs \ SONET-MIB - sonetPathCurrentCVs | 10G WIS status 3 SONET-MIB - sonetPathCurrentUASs | + SONET-MIB - sonetPathIntervalESs | 10G WIS SONET-MIB - sonetPathIntervalSESs | path block SONET-MIB - sonetPathIntervalCVs / error count SONET-MIB - sonetPathIntervalUASs / SONET-MIB - sonetPathIntervalValidData none required

ETHER-WIS - etherWisFarEndPathCurrentStatus 10G WIS status 3

SONET-MIB - sonetFarEndPathCurrentESs \ SONET-MIB - sonetFarEndPathCurrentSESs \ SONET-MIB - sonetFarEndPathCurrentCVs | 10G WIS status 3 SONET-MIB - sonetFarEndPathCurrentUASs | + SONET-MIB - sonetFarEndPathIntervalESs | 10G WIS far end SONET-MIB - sonetFarEndPathIntervalSESs | path block SONET-MIB - sonetFarEndPathIntervalCVs / error count SONET-MIB - sonetFarEndPathIntervalUASs / SONET-MIB - sonetFarEndPathIntervalValidData 10G WIS status 3

MAU-MIB - ifMauIfIndex none required MAU-MIB - ifMauIndex none required MAU-MIB - ifMauType 10G WIS control 2 MAU-MIB - ifMauStatus WIS control 1 MAU-MIB - ifMauMediaAvailable \ WIS status 1 + MAU-MIB - ifMauMediaAvailableStateExits / 10G WIS status 3 MAU-MIB - ifMauJabberState none required MAU-MIB - ifMauJabberingStateEnters none required MAU-MIB - ifMauFalseCarriers none required MAU-MIB - ifMauDefaultType 10G WIS control 2 MAU-MIB - ifMauAutoNegSupported none required MAU-MIB - ifMauTypeListBits 10G WIS status 2

Structure of the MIB Module

Four tables are defined in this MIB module.

etherWisDeviceTable

The purpose of this table is to define managed objects to control the WIS test pattern mode. These objects are required to support mandatory and optional WIS test features specified in [802.3ae] subclause 50.3.8.

The etherWisDeviceTable is a sparse augmentation of the sonetMediumTable of the SONET-MIB -- in other words, for each entry in the etherWisDeviceTable there MUST be an entry in the sonetMediumTable and the same ifIndex value MUST be used for both entries.

etherWisSectionCurrentTable

The purpose of this table is to define managed objects for the transmitted and received section trace messages (J0 byte).

The etherWisSectionCurrentTable is a sparse augmentation of the sonetSectionCurrentTable of the SONET-MIB -- in other words, for each entry in the etherWisSectionCurrentTable there MUST be an entry in the sonetSectionCurrentTable and the same ifIndex value MUST be used for both entries.

etherWisPathCurrentTable

The purpose of this table is to define managed objects for the current WIS path layer status and for the transmitted and received path trace messages (J1 byte). The path layer status object is provided because the WIS supports some near-end path status conditions that are not reported in sonetPathCurrentStatus.

The etherWisPathCurrentTable is a sparse augmentation of the sonetPathCurrentTable of the SONET-MIB -- in other words, for each entry in the etherWisPathCurrentTable there MUST be an entry in the sonetPathCurrentTable and the same ifIndex value MUST be used for both entries.

etherWisFarEndPathCurrentTable

The purpose of this table is to define a managed object for the current status of the far end of the path. This object is provided because the WIS supports some far-end path status conditions that are not reported in sonetPathCurrentStatus.

The etherWisFarEndPathCurrentTable is a sparse augmentation of the sonetFarEndPathCurrentTable of the SONET-MIB -- in other words, for each entry in the etherWisFarEndPathCurrentTable there MUST be an entry in the sonetFarEndPathCurrentTable and the same ifIndex value MUST be used for both entries.

Object Definitions

ETHER-WIS DEFINITIONS ::= BEGIN

IMPORTS

   MODULE-IDENTITY, OBJECT-TYPE,
   Gauge32, transmission
       FROM SNMPv2-SMI
   ifIndex
       FROM IF-MIB
   MODULE-COMPLIANCE, OBJECT-GROUP
       FROM SNMPv2-CONF
   sonetMediumStuff2, sonetSectionStuff2,
   sonetLineStuff2, sonetFarEndLineStuff2,
   sonetPathStuff2, sonetFarEndPathStuff2,
   sonetMediumType, sonetMediumLineCoding,
   sonetMediumLineType, sonetMediumCircuitIdentifier,
   sonetMediumLoopbackConfig, sonetSESthresholdSet,
   sonetPathCurrentWidth
       FROM SONET-MIB;

etherWisMIB MODULE-IDENTITY

   LAST-UPDATED "200309190000Z"  -- September 19, 2003
       ORGANIZATION "IETF Ethernet Interfaces and Hub MIB
                    Working Group"
       CONTACT-INFO
          "WG charter:
             http://www.ietf.org/html.charters/hubmib-charter.html
           Mailing Lists:
             General Discussion: [email protected]
             To Subscribe: [email protected]
             In Body: subscribe your_email_address
            Chair: Dan Romascanu
           Postal: Avaya Inc.
                   Atidim Technology Park, Bldg. 3
                   Tel Aviv 61131
                   Israel
              Tel: +972 3 645 8414
           E-mail: [email protected]
           Editor: C. M. Heard
           Postal: 600 Rainbow Dr. #141
                   Mountain View, CA 94041-2542
                   USA
              Tel: +1 650-964-8391
           E-mail: [email protected]"
   DESCRIPTION
     "The objects in this MIB module are used in conjunction
     with objects in the SONET-MIB and the MAU-MIB to manage
     the Ethernet WAN Interface Sublayer (WIS).
     The following reference is used throughout this MIB module:
     [IEEE 802.3 Std] refers to:
        IEEE Std 802.3, 2000 Edition: 'IEEE Standard for
        Information technology - Telecommunications and
        information exchange between systems - Local and
        metropolitan area networks - Specific requirements -
        Part 3: Carrier sense multiple access with collision
        detection (CSMA/CD) access method and physical layer
        specifications', as amended by IEEE Std 802.3ae-2002,
        'IEEE Standard for Carrier Sense Multiple Access with
        Collision Detection (CSMA/CD) Access Method and
        Physical Layer Specifications - Media Access Control
        (MAC) Parameters, Physical Layer and Management
        Parameters for 10 Gb/s Operation', 30 August 2002.
     Of particular interest are Clause 50, 'WAN Interface
     Sublayer (WIS), type 10GBASE-W', Clause 30, '10Mb/s,
     100Mb/s, 1000Mb/s, and 10Gb/s MAC Control, and Link
     Aggregation Management', and Clause 45, 'Management
     Data Input/Output (MDIO) Interface'.
     Copyright (C) The Internet Society (2003).  This version
     of this MIB module is part of RFC 3637;  see the RFC
     itself for full legal notices."
   REVISION    "200309190000Z"  -- September 19, 2003
   DESCRIPTION "Initial version, published as RFC 3637."
   ::= { transmission 134 }

-- The main sections of the module

etherWisObjects OBJECT IDENTIFIER ::= { etherWisMIB 1 }

etherWisObjectsPath OBJECT IDENTIFIER ::= { etherWisMIB 2 }

etherWisConformance OBJECT IDENTIFIER ::= { etherWisMIB 3 }

-- groups in the Ethernet WIS MIB module

etherWisDevice OBJECT IDENTIFIER ::= { etherWisObjects 1 }

etherWisSection OBJECT IDENTIFIER ::= { etherWisObjects 2 }

etherWisPath OBJECT IDENTIFIER ::= { etherWisObjectsPath 1 }

etherWisFarEndPath OBJECT IDENTIFIER ::= { etherWisObjectsPath 2 }

-- The Device group

-- These objects provide WIS extensions to -- the SONET-MIB Medium Group.

etherWisDeviceTable OBJECT-TYPE

   SYNTAX  SEQUENCE OF EtherWisDeviceEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
      "The table for Ethernet WIS devices"
    ::= { etherWisDevice 1 }

etherWisDeviceEntry OBJECT-TYPE

   SYNTAX  EtherWisDeviceEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
      "An entry in the Ethernet WIS device table.  For each
      instance of this object there MUST be a corresponding
      instance of sonetMediumEntry."
   INDEX  { ifIndex }
    ::= { etherWisDeviceTable 1 }

EtherWisDeviceEntry ::=

   SEQUENCE {
       etherWisDeviceTxTestPatternMode     INTEGER,
       etherWisDeviceRxTestPatternMode     INTEGER,
       etherWisDeviceRxTestPatternErrors   Gauge32
       }

etherWisDeviceTxTestPatternMode OBJECT-TYPE

   SYNTAX  INTEGER {
               none(1),
               squareWave(2),
               prbs31(3),
               mixedFrequency(4)
           }
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
      "This variable controls the transmit test pattern mode.
      The value none(1) puts the the WIS transmit path into
      the normal operating mode.  The value squareWave(2) puts
      the WIS transmit path into the square wave test pattern
      mode described in [IEEE 802.3 Std.] subclause 50.3.8.1.
      The value prbs31(3) puts the WIS transmit path into the
      PRBS31 test pattern mode described in [IEEE 802.3 Std.]
      subclause 50.3.8.2.  The value mixedFrequency(4) puts the
      WIS transmit path into the mixed frequency test pattern
      mode described in [IEEE 802.3 Std.] subclause 50.3.8.3.
      Any attempt to set this object to a value other than
      none(1) when the corresponding instance of ifAdminStatus
      has the value up(1) MUST be rejected with the error
      inconsistentValue, and any attempt to set the corresponding
      instance of ifAdminStatus to the value up(1) when an
      instance of this object has a value other than none(1)
      MUST be rejected with the error inconsistentValue."
   REFERENCE
      "[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
      checker, 45.2.2.6, 10G WIS control 2 register (2.7), and
      45.2.2.7.2, PRBS31 pattern testing ability (2.8.1)."
    ::= { etherWisDeviceEntry 1 }

etherWisDeviceRxTestPatternMode OBJECT-TYPE

   SYNTAX  INTEGER {
               none(1),
               prbs31(3),
               mixedFrequency(4)
           }
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
      "This variable controls the receive test pattern mode.
      The value none(1) puts the the WIS receive path into the
      normal operating mode.  The value prbs31(3) puts the WIS
      receive path into the PRBS31 test pattern mode described
      in [IEEE 802.3 Std.] subclause 50.3.8.2.  The value
      mixedFrequency(4) puts the WIS receive path into the mixed
      frequency test pattern mode described in [IEEE 802.3 Std.]
      subclause 50.3.8.3.  Any attempt to set this object to a
      value other than none(1) when the corresponding instance
      of ifAdminStatus has the value up(1) MUST be rejected with
      the error inconsistentValue, and any attempt to set the
      corresponding instance of ifAdminStatus to the value up(1)
      when an instance of this object has a value other than
      none(1) MUST be rejected with the error inconsistentValue."
   REFERENCE
      "[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
      checker, 45.2.2.6, 10G WIS control 2 register (2.7), and
      45.2.2.7.2, PRBS31 pattern testing ability (2.8.1)."
    ::= { etherWisDeviceEntry 2 }

etherWisDeviceRxTestPatternErrors OBJECT-TYPE

   SYNTAX  Gauge32 ( 0..65535 )
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
      "This object counts the number of errors detected when the
      WIS receive path is operating in the PRBS31 test pattern
      mode.  It is reset to zero when the WIS receive path
      initially enters that mode, and it increments each time
      the PRBS pattern checker detects an error as described in
      [IEEE 802.3 Std.] subclause 50.3.8.2 unless its value is
      65535, in which case it remains unchanged.  This object is
      writeable so that it may be reset upon explicit request
      of a command generator application while the WIS receive
      path continues to operate in PRBS31 test pattern mode."
   REFERENCE
      "[IEEE 802.3 Std.], 50.3.8, WIS test pattern generator and
      checker, 45.2.2.7.2, PRBS31 pattern testing ability
      (2.8.1), and 45.2.2.8, 10G WIS test pattern error counter
      register (2.9)."
    ::= { etherWisDeviceEntry 3 }

-- The Section group

-- These objects provide WIS extensions to -- the SONET-MIB Section Group.

etherWisSectionCurrentTable OBJECT-TYPE

   SYNTAX  SEQUENCE OF EtherWisSectionCurrentEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
      "The table for the current state of Ethernet WIS sections."
    ::= { etherWisSection 1 }

etherWisSectionCurrentEntry OBJECT-TYPE

   SYNTAX  EtherWisSectionCurrentEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
      "An entry in the etherWisSectionCurrentTable.  For each
      instance of this object there MUST be a corresponding
      instance of sonetSectionCurrentEntry."
   INDEX  { ifIndex }
    ::= { etherWisSectionCurrentTable 1 }

EtherWisSectionCurrentEntry ::=

   SEQUENCE {
       etherWisSectionCurrentJ0Transmitted OCTET STRING,
       etherWisSectionCurrentJ0Received    OCTET STRING
       }

etherWisSectionCurrentJ0Transmitted OBJECT-TYPE

   SYNTAX  OCTET STRING (SIZE (16))
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
      "This is the 16-octet section trace message that
      is transmitted in the J0 byte.  The value SHOULD
      be '89'h followed by fifteen octets of '00'h
      (or some cyclic shift thereof) when the section
      trace function is not used, and the implementation
      SHOULD use that value (or a cyclic shift thereof)
      as a default if no other value has been set."
   REFERENCE
      "[IEEE 802.3 Std.], 30.8.1.1.8, aJ0ValueTX."
    ::= { etherWisSectionCurrentEntry 1 }

etherWisSectionCurrentJ0Received OBJECT-TYPE

   SYNTAX  OCTET STRING (SIZE (16))
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
      "This is the 16-octet section trace message that
      was most recently received in the J0 byte."
   REFERENCE
      "[IEEE 802.3 Std.], 30.8.1.1.9, aJ0ValueRX."
    ::= { etherWisSectionCurrentEntry 2 }

-- The Path group

-- These objects provide WIS extensions to -- the SONET-MIB Path Group.

etherWisPathCurrentTable OBJECT-TYPE

   SYNTAX  SEQUENCE OF EtherWisPathCurrentEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
      "The table for the current state of Ethernet WIS paths."
    ::= { etherWisPath 1 }

etherWisPathCurrentEntry OBJECT-TYPE

   SYNTAX  EtherWisPathCurrentEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
      "An entry in the etherWisPathCurrentTable.  For each
      instance of this object there MUST be a corresponding
      instance of sonetPathCurrentEntry."
   INDEX  { ifIndex }
    ::= { etherWisPathCurrentTable 1 }

EtherWisPathCurrentEntry ::=

   SEQUENCE {
       etherWisPathCurrentStatus           BITS,
       etherWisPathCurrentJ1Transmitted    OCTET STRING,
       etherWisPathCurrentJ1Received       OCTET STRING
       }

etherWisPathCurrentStatus OBJECT-TYPE

   SYNTAX  BITS {
               etherWisPathLOP(0),
               etherWisPathAIS(1),
               etherWisPathPLM(2),
               etherWisPathLCD(3)
           }
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
      "This variable indicates the current status of the
      path payload with a bit map that can indicate multiple
      defects at once.  The bit positions are assigned as
      follows:
      etherWisPathLOP(0)
         This bit is set to indicate that an
         LOP-P (Loss of Pointer - Path) defect
         is being experienced.  Note:  when this
         bit is set, sonetPathSTSLOP MUST be set
         in the corresponding instance of
         sonetPathCurrentStatus.
      etherWisPathAIS(1)
         This bit is set to indicate that an
         AIS-P (Alarm Indication Signal - Path)
         defect is being experienced.  Note:  when
         this bit is set, sonetPathSTSAIS MUST be
         set in the corresponding instance of
         sonetPathCurrentStatus.
      etherWisPathPLM(1)
         This bit is set to indicate that a
         PLM-P (Payload Label Mismatch - Path)
         defect is being experienced.  Note:  when
         this bit is set, sonetPathSignalLabelMismatch
         MUST be set in the corresponding instance of
         sonetPathCurrentStatus.
      etherWisPathLCD(3)
         This bit is set to indicate that an
         LCD-P (Loss of Codegroup Delination - Path)
         defect is being experienced.  Since this
         defect is detected by the PCS and not by
         the path layer itself, there is no
         corresponding bit in sonetPathCurrentStatus."
   REFERENCE
      "[IEEE 802.3 Std.], 30.8.1.1.18, aPathStatus."
    ::= { etherWisPathCurrentEntry 1 }

etherWisPathCurrentJ1Transmitted OBJECT-TYPE

   SYNTAX  OCTET STRING (SIZE (16))
   MAX-ACCESS  read-write
   STATUS  current
   DESCRIPTION
      "This is the 16-octet path trace message that
      is transmitted in the J1 byte.  The value SHOULD
      be '89'h followed by fifteen octets of '00'h
      (or some cyclic shift thereof) when the path
      trace function is not used, and the implementation
      SHOULD use that value (or a cyclic shift thereof)
      as a default if no other value has been set."
   REFERENCE
      "[IEEE 802.3 Std.], 30.8.1.1.23, aJ1ValueTX."
    ::= { etherWisPathCurrentEntry 2 }

etherWisPathCurrentJ1Received OBJECT-TYPE

   SYNTAX  OCTET STRING (SIZE (16))
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
      "This is the 16-octet path trace message that
      was most recently received in the J1 byte."
   REFERENCE
      "[IEEE 802.3 Std.], 30.8.1.1.24, aJ1ValueRX."
    ::= { etherWisPathCurrentEntry 3 }

-- The Far End Path group

-- These objects provide WIS extensions to -- the SONET-MIB Far End Path Group.

etherWisFarEndPathCurrentTable OBJECT-TYPE

   SYNTAX  SEQUENCE OF EtherWisFarEndPathCurrentEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
      "The table for the current far-end state of Ethernet WIS
      paths."
    ::= { etherWisFarEndPath 1 }

etherWisFarEndPathCurrentEntry OBJECT-TYPE

   SYNTAX  EtherWisFarEndPathCurrentEntry
   MAX-ACCESS  not-accessible
   STATUS  current
   DESCRIPTION
      "An entry in the etherWisFarEndPathCurrentTable.  For each
      instance of this object there MUST be a corresponding
      instance of sonetFarEndPathCurrentEntry."
   INDEX  { ifIndex }
    ::= { etherWisFarEndPathCurrentTable 1 }

EtherWisFarEndPathCurrentEntry ::=

   SEQUENCE {
       etherWisFarEndPathCurrentStatus     BITS
       }

etherWisFarEndPathCurrentStatus OBJECT-TYPE

   SYNTAX  BITS {
               etherWisFarEndPayloadDefect(0),
               etherWisFarEndServerDefect(1)
           }
   MAX-ACCESS  read-only
   STATUS  current
   DESCRIPTION
      "This variable indicates the current status at the
      far end of the path using a bit map that can indicate
      multiple defects at once.  The bit positions are
      assigned as follows:
      etherWisFarEndPayloadDefect(0)
         A far end payload defect (i.e., far end
         PLM-P or LCD-P) is currently being signaled
         in G1 bits 5-7.
      etherWisFarEndServerDefect(1)
         A far end server defect (i.e., far end
         LOP-P or AIS-P) is currently being signaled
         in G1 bits 5-7.  Note:  when this bit is set,
         sonetPathSTSRDI MUST be set in the corresponding
         instance of sonetPathCurrentStatus."
   REFERENCE
      "[IEEE 802.3 Std.], 30.8.1.1.25, aFarEndPathStatus."
    ::= { etherWisFarEndPathCurrentEntry 1 }

-- -- Conformance Statements --

etherWisGroups OBJECT IDENTIFIER ::= { etherWisConformance 1 }

etherWisCompliances OBJECT IDENTIFIER ::= { etherWisConformance 2 }

-- Object Groups

etherWisDeviceGroupBasic OBJECT-GROUP

   OBJECTS {
       etherWisDeviceTxTestPatternMode,
       etherWisDeviceRxTestPatternMode
       }
   STATUS  current
   DESCRIPTION
      "A collection of objects that support test
      features required of all WIS devices."
    ::= { etherWisGroups 1 }

etherWisDeviceGroupExtra OBJECT-GROUP

   OBJECTS {
       etherWisDeviceRxTestPatternErrors
       }
   STATUS  current
   DESCRIPTION
      "A collection of objects that support
      optional WIS device test features."
    ::= { etherWisGroups 2 }

etherWisSectionGroup OBJECT-GROUP

   OBJECTS {
       etherWisSectionCurrentJ0Transmitted,
       etherWisSectionCurrentJ0Received
       }
   STATUS  current
   DESCRIPTION
      "A collection of objects that provide
      required information about a WIS section."
    ::= { etherWisGroups 3 }

etherWisPathGroup OBJECT-GROUP

   OBJECTS {
       etherWisPathCurrentStatus,
       etherWisPathCurrentJ1Transmitted,
       etherWisPathCurrentJ1Received
       }
   STATUS  current
   DESCRIPTION
      "A collection of objects that provide
      required information about a WIS path."
    ::= { etherWisGroups 4 }

etherWisFarEndPathGroup OBJECT-GROUP

   OBJECTS {
       etherWisFarEndPathCurrentStatus
       }
   STATUS  current
   DESCRIPTION
      "A collection of objects that provide required
      information about the far end of a WIS path."
    ::= { etherWisGroups 5 }

-- Compliance Statements

etherWisCompliance MODULE-COMPLIANCE

   STATUS  current
   DESCRIPTION
      "The compliance statement for interfaces that include
      the Ethernet WIS.  Compliance with the following
      external compliance statements is prerequisite:
      MIB Module             Compliance Statement
      ----------             --------------------
      IF-MIB                 ifCompliance3
      IF-INVERTED-STACK-MIB  ifInvCompliance
      EtherLike-MIB          dot3Compliance2
      MAU-MIB                mauModIfCompl3"
   MODULE  -- this module
       MANDATORY-GROUPS {
           etherWisDeviceGroupBasic,
           etherWisSectionGroup,
           etherWisPathGroup,
           etherWisFarEndPathGroup
           }
       OBJECT       etherWisDeviceTxTestPatternMode
       SYNTAX       INTEGER {
           none(1),
           squareWave(2),
           mixedFrequency(4)
           }
       DESCRIPTION
           "Support for values other than none(1),
           squareWave(2), and mixedFrequency(4)
           is not required."
       OBJECT       etherWisDeviceRxTestPatternMode
       SYNTAX       INTEGER {
           none(1),
           mixedFrequency(4)
           }
       DESCRIPTION
           "Support for values other than none(1)
           and mixedFrequency(4) is not required."
       GROUP        etherWisDeviceGroupExtra
       DESCRIPTION
           "Implementation of this group, along with support for
           the value prbs31(3) for etherWisDeviceTxTestPatternMode
           and etherWisDeviceRxTestPatternMode, is necessary if the
           optional PRBS31 test pattern mode is to be supported."
       OBJECT       etherWisDeviceRxTestPatternErrors
       WRITE-SYNTAX Gauge32 ( 0 )
       DESCRIPTION
           "An implementation is not required to
           allow values other than zero to be
           written to this object."
   MODULE SONET-MIB
       MANDATORY-GROUPS {
           sonetMediumStuff2,
           sonetSectionStuff2,
           sonetLineStuff2,
           sonetFarEndLineStuff2,
           sonetPathStuff2,
           sonetFarEndPathStuff2
           }
       OBJECT       sonetMediumType
       SYNTAX       INTEGER {
           sonet(1)
           }
       MIN-ACCESS   read-only
       DESCRIPTION
           "Write access is not required, nor is support
           for any value other than sonet(1)."
       OBJECT       sonetMediumLineCoding
       SYNTAX       INTEGER {
           sonetMediumNRZ(4)
           }
       MIN-ACCESS   read-only
       DESCRIPTION
           "Write access is not required, nor is support
           for any value other than sonetMediumNRZ(4)."
       OBJECT       sonetMediumLineType
       MIN-ACCESS   read-only
       DESCRIPTION
           "Write access is not required."
       OBJECT       sonetMediumCircuitIdentifier
       MIN-ACCESS   read-only
       DESCRIPTION
           "Write access is not required."
       OBJECT       sonetMediumLoopbackConfig
       SYNTAX       BITS {
           sonetNoLoop(0),
           sonetFacilityLoop(1)
           }
       MIN-ACCESS   read-only
       DESCRIPTION
           "Write access is not required, nor is support for values
           other than sonetNoLoop(0) and sonetFacilityLoop(1)."
       OBJECT       sonetSESthresholdSet
       MIN-ACCESS   read-only
       DESCRIPTION
           "Write access is not required, and only one
           of the enumerated values need be supported."
       OBJECT       sonetPathCurrentWidth
       SYNTAX       INTEGER {
           sts192cSTM64(6)
           }
       MIN-ACCESS   read-only
       DESCRIPTION
           "Write access is not required, nor is support
           for any value other than sts192cSTM64(6)."
    ::= { etherWisCompliances 1 }

END

Intellectual Property Statement

The IETF takes no position regarding the validity or scope of any intellectual property or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; neither does it represent that it has made any effort to identify any such rights. Information on the IETF's procedures with respect to rights in standards-track and standards-related documentation can be found in BCP-11. Copies of claims of rights made available for publication and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementors or users of this specification can be obtained from the IETF Secretariat.

The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights which may cover technology that may be required to practice this standard. Please address the information to the IETF Executive Director.

Acknowledgments

This document is a product of the IETF Hub MIB and AToM MIB Working Groups. It builds upon the work of the IEEE P802.3ae 10 Gigabit Ethernet Task Force.

Security Considerations

There are five managed objects defined in this MIB module that have a MAX-ACCESS clause of read-write: etherWisDeviceTxTestPatternMode, etherWisDeviceRxTestPatternMode, etherWisDeviceRxTestPatternErrors, etherWisSectionCurrentJ0Transmitted, and etherWisPathCurrentJ1Transmitted. Writing to these objects can have the following potentially disruptive effects on network operation:

o changing the transmit or receive test pattern mode or modifying

  the accumulated error count from a PRBS31 pattern test on an
  administratively disabled 10GBASE-W interface, which can
  interfere with an in-progress pattern test;

o modifying the transmitted section trace and/or path trace

  message on an operational 10GBASE-W interface, which can cause
  connectivity alarms to be raised at the remote of the link.

The user of this MIB module must therefore be aware that support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations.

The readable objects in this MIB module (i.e., those with MAX-ACCESS other than not-accessible) may be considered sensitive in some environments since, collectively, they provide information about the performance of network interfaces and can reveal some aspects of their configuration. In such environments it is important to control even GET and NOTIFY access to these objects and possibly even to encrypt their values when sending them over the network via SNMP.

SNMP versions prior to SNMPv3 did not include adequate security. Even if the network itself is secure (for example by using IPSec), even then, there is no control as to who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB module.

It is RECOMMENDED that implementers consider the security features as provided by the SNMPv3 framework (see RFC3410, section 8), including full support for the SNMPv3 cryptographic mechanisms (for authentication and privacy).

Further, deployment of SNMP versions prior to SNMPv3 is NOT RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to enable cryptographic security. It is then a customer/operator responsibility to ensure that the SNMP entity giving access to an instance of this MIB module is properly configured to give access to the objects only to those principals (users) that have legitimate rights to indeed GET or SET (change/create/delete) them.

References

Normative References

RFC2119 Bradner, S., "Key words for use in RFCs to Indicate

           Requirements Levels", BCP 14, RFC 2119, March 1997.

RFC2578 McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,

           Rose, M. and S. Waldbusser, "Structure of Management
           Information Version 2 (SMIv2)", STD 58, RFC 2578, April
           1999.

RFC2579 McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,

           Rose, M. and S. Waldbusser, "Textual Conventions for
           SMIv2", STD 58, RFC 2579, April 1999.

RFC2580 McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,

           Rose, M. and S. Waldbusser, "Conformance Statements for
           SMIv2", STD 58, RFC 2580, April 1999.

RFC2863 McCloghrie, K. and F. Kastenholz, "The Interfaces Group

           MIB", RFC 2863, June 2000.

RFC2864 McCloghrie, K. and G. Hanson, "The Inverted Stack Table

           Extension to the Interfaces Group MIB", RFC 2864, June
           2000.

RFC3592 Tesink, K., "Definitions of Managed Objects for the

           Synchronous Optical Network/Synchronous Digital Hierarchy
           (SONET/SDH) Interface Type", RFC 3592, September 2003.

[T1.231] American National Standard for Telecommunications -

           Digital Hierarchy - Layer 1 In-Service Digital
           Transmission Performance Monitoring, ANSI T1.231-1997,
           September 1997.

RFC3635 Flick, J., "Definitions of Managed Objects for the

           Ethernet-like Interface Types", RFC 3635, September 2003.

RFC3636 Flick, J., "Definitions of Managed Objects for IEEE 802.3

           Medium Attachment Units (MAUs)", RFC 3636, September
           2003.

[802.3ae] Institute of Electrical and Electronic Engineers, IEEE

           Std 802.3ae-2002, "IEEE Standard for Carrier Sense
           Multiple Access with Collision Detection (CSMA/CD) Access
           Method and Physical Layer Specifications - Media Access
           Control (MAC) Parameters, Physical Layer and Management
           Parameters for 10 Gb/s Operation", August 2002.

Informative References

RFC3410 Case, J., Mundy, R., Partain, D. and B. Stewart,

           "Introduction and Applicability Statements for Internet-
           Standard Management Framework", RFC 3410, December 2002.

Appendix A: Collection of Performance Data Using WIS MDIO Registers

The purpose of this appendix is to illustrate how the WIS MDIO registers specified in [802.3ae] subclause 45.2.2 (and more specifically the subset required by [802.3ae] subclause 50.3.11) can be used to collect performance data either according to the conventions adopted by this document or according to the conventions specified in [802.3ae] Clause 30.

For an agent implementing the SNMP managed objects required by this document the first step in collecting WIS performance data would be to poll the 10G WIS status 3 register and the various error count registers (10G WIS section BIP error count, 10G WIS line BIP errors, 10G WIS far end line BIP errors, 10G WIS path block error count, and 10G WIS far end path block error count) once per second. The 10G WIS status 3 register bits are all latched until read and so would indicate whether a given defect occurred any time during the previous second. The error count registers roll over modulo 2^16 or 2^32, and so to find the number of errors within the previous second the agent would need to subtract (modulo 2^16 or 2^32) the current reading from the reading taken one second ago. Armed with that information, the agent could determine for any layer whether the one second interval was an errored second, a severely errored second (that requires comparison with a threshold unless a defect is present), or a severely errored frame second. Determining whether a given second is or is not part of unavailable time requires additional logic; the most straightforward and accurate method is the delay-line approach outlined in Appendix A of RFC3592. With that information available the agent would be able to determine by how much each current count should be incremented (including effects of inhibiting). Implementations that conform to [T1.231] would end each 15-minute interval on time-of-day clock 1/4 hour boundaries; if the delay-line approach is used then a time-of-day timestamp would accompany the one-second statistics. At the end of each interval the current registers would be pushed onto the history stack and then would be cleared. The xyxIntervalValidData flags would be set to False(2) if the number of samples was not between 890 and 910 or, in the case of far-end counts, if a near-end defect occurred during the just-completed interval (see [T1.231] Section 9.1.2.2 for details).

An agent implementing the [802.3ae] Clause 30 oWIS objects could also start by polling the 10G WIS status 3 register and the various error count registers to find the defects and error counts for the previous second, and it could determine the number of errors and whether the second was an errored second, a severely errored second, or a severely errored frame second in the same manner as above. The rest of the process would simply be to increment the generalized non- resetable counters without consideration of any inhibiting rules.

Contributors

Mike Ayers 1204 Knox Ave. San Jose, CA 95122 USA

Phone: +1 408 857 6810 EMail: [email protected]

John Flick Hewlett-Packard Company 8000 Foothills Blvd. M/S 5557 Roseville, CA 95747-5557 USA

Phone: +1 916 785 4018 Fax: +1 916 785 1199 EMail: [email protected]

Kam Lam Lucent Technologies 101 Crawfords Corner Road, Room 4C-616A Holmdel, NJ 07733 USA

Phone: +1 732 949 8338 EMail: [email protected]

Kerry McDonald Institute for Applied Supercomputing California State University San Bernardino

EMail: [email protected]

      [email protected]

K. C. Norseth L-3 Communications 640 N. 2200 West. Salt Lake City, Utah 84116-0850 USA

Phone: +1 801 594 2809 EMail: [email protected]

      [email protected]

Kaj Tesink Telcordia Technologies 331 Newman Springs Road P.O. Box 7020 Red Bank, NJ 07701-7020 USA

Phone: +1 732 758 5254 EMail: [email protected]

Editor's Address

C. M. Heard 600 Rainbow Dr. #141 Mountain View, CA 94041-2542 USA

Phone: +1 650 964 8391 EMail: [email protected]

Full Copyright Statement

Copyright (C) The Internet Society (2003). All Rights Reserved.

This document and translations of it may be copied and furnished to others, and derivative works that comment on or otherwise explain it or assist in its implementation may be prepared, copied, published and distributed, in whole or in part, without restriction of any kind, provided that the above copyright notice and this paragraph are included on all such copies and derivative works. However, this document itself may not be modified in any way, such as by removing the copyright notice or references to the Internet Society or other Internet organizations, except as needed for the purpose of developing Internet standards in which case the procedures for copyrights defined in the Internet Standards process must be followed, or as required to translate it into languages other than English.

The limited permissions granted above are perpetual and will not be revoked by the Internet Society or its successors or assignees.

This document and the information contained herein is provided on an "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Acknowledgement

Funding for the RFC Editor function is currently provided by the Internet Society.