RFC1289

From RFC-Wiki

Network Working Group J. Saperia Request for Comments: 1289 Digital Equipment Corporation

                                                       December 1991
                 DECnet Phase IV MIB Extensions

Status of this Memo

This memo is an extension to the SNMP MIB. This RFC specifies an IAB standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "IAB Official Protocol Standards" for the standardization state and status of this protocol. Distribution of this memo is unlimited.

Abstract

This memo defines a set of DECnet Phase IV extensions that have been created for the Internet MIB. When used in conjunction with the structure of management information (RFC 1155), the management information base for network management of TCP/IP-based internets (RFC 1213) and the Simple Network Management Protocol (RFC 1157), it will be possible to provide integrated network management of combined TCP/IP and DECnet Phase IV based internets. This document was produced by the DECnet Phase IV MIB working group of the Internet Engineering Task Force (IETF).

Introduction

With the adoption of The Simple Network Management Protocol (RFC 1157), the management information base for network management of TCP/IP-based internets (RFC 1213), and the structure of management information (RFC 1155), by the Internet, and a large number of vendor

implementations of these standards in commercially available products, it became possible to provide a higher level of effective network management in TCP/IP-based internets than previously available. With the growth in the use of these standards, network managers desired to use this environment as a base for providing integrated network management of multi-protocol networks.

DECnet Phase IV is one widely used protocol which often coexists in IP-based internets. This memo provides the mechanisms by which IP- based management stations can effectively manage DECnet Phase IV based systems (especially router products) in an integrated fashion through the use of the standard Internet SMI, MIB and Simple Network Management Protocol.

DECnet Phase IV objects have been defined to be used in conjunction with the Internet MIB to allow access and control of these new objects by the Internet community. Additional support for other DECnet-based protocols such as RBMS (remote bridge management software) or other Digital Equipment Corporation Specific Hardware platforms is not included in this document.

Selected Objects

The objects included in this memo have been created from the DIGITAL Network Architecture Network Management Functional Specification Version 4.0.0 Dated July 1983. An attempt has been made to provide a reasonable ordering of these variables into groups. These groups are:

 o  System Group
 o  Network Management Group
 o  Session Group
 o  End Group
 o  Routing Group
 o  Circuit Group
 o  DDCMP Group
 o  DDCMP Multipoint Control Group
 o  Ethernet Group
 o  Counters Group
 o  Adjacency Group
 o  Line Group
 o  Non Broadcast Line Group
 o  Area Group

An effort has also been made to preserve the original syntax of the object wherever possible, for example, a DECnet Phase IV object is Executor State. This was originally coded as a NICE (Network Information and Control Exchange) data type which is a Coded single field object of 1 byte in length. When converted for inclusion into the Internet MIB using the Internet SMI, it became an enumerated integer.

Objects

All objects in this memo are described using the standard Internet SMI and BER of RFC 1155. A complete description of an object will include the name, syntax and encoding. Just as with objects supported in the MIB (RFC 1156), an object name is identified with an object identifier which has been administratively assigned. This identifies an Object Type. When an object type is combined with a specific instance, the particular object is uniquely identified. The use of Object Descriptors in this memo is consistent with that of RFC 1156 - they are text strings meant to be read by humans. The descriptors have been taken from the original DIGITAL Network Architecture Network Management Functional Specification Version 4.0.0 Dated July 1983 which defined DECnet Phase IV objects. These names were then massaged to put them in a form as consistent as possible with object type names listed in the standard Internet MIB. Object defintion information is also taken directly from the Network Architecture Network Managment Functional Specification cited above wherever possible. In this document, EXECUTOR is intended to reference only the DECnet software and is not intended to effect any other protocols which may be running on the system.

Format of Definitions

An object in this memo is specified by five fields of information: Object, Syntax, Definition, Access, and Status.

The OBJECT is a textual name (OBJECT DESCRIPTOR) for that object type combined with an administratively obtained OBJECT IDENTIFIER.

SYNTAX: For each object type, its abstract syntax is presented using the ASN.1 specified in RFC 1155.

DEFINITION: A general description of the object type. Its original purpose in the DECnet Phase IV environment is given so that all implementers and users will consistently interpret the information contained in each object type. Changes in format to make the object consistent with RFC 1155 are also noted.

ACCESS: The standard access keywords supported in RFC 1156 are used. The keywords used in this MIB are: read-only, read-write, and, not- accessible.

STATUS: The status field is used to describe with a single keyword whether the object type is mandatory or optional. Status keywords of obsolete and deprecated are not used in this memo since this is the first version of the DECnet Phase IV MIB.

Textual Conventions

New datatypes have been introduced as a textual conventions in this DECnet Phase IV MIB document. The purpose of these additions is to facilitate understanding of new objects in this MIB. No changes to the SMI or the SNMP are necessary to support these conventions which are described in 4.0 (Object Definitions).

Object Definitions

        RFC1289-phivMIB
        DEFINITIONS ::= BEGIN
        IMPORTS
           Gauge
              FROM RFC1155-SMI
            OBJECT-TYPE
               FROM RFC-1212
            mib-2, DisplayString
              FROM RFC1213-MIB;
   -- DECNet Phase-IV MIB
        phiv             OBJECT IDENTIFIER ::= { mib-2 18 }
   -- textual conventions
   PhivAddr ::= OCTET STRING (SIZE (2))
   -- This data type is intended as a short word representation of
   -- standard DECnet Phase IV addresses. DECnet addresses are
   -- hierarchically structured numbers assigned to a particular
   -- DECnet node. The address is structured so that the area
   -- number is contained in the most significant 6 bits of the
   -- first octet.  The next 2 bits of the first octet contain
   -- the first two bits of the host address.  The remainder of
   -- the host address is contained in the second octet.
   PhivCounter ::= INTEGER
   -- This data type has been created for DECnet  counters.  These
   -- counters latch at their maximum specified value until either
   -- the system is restared, or they are reset to zero by the user
   -- or management software.
   -- groups in the decnetiv mib
         phivSystem             OBJECT IDENTIFIER ::= { phiv 1 }
         phivManagement         OBJECT IDENTIFIER ::= { phiv 2 }
         session                OBJECT IDENTIFIER ::= { phiv 3 }
         end                    OBJECT IDENTIFIER ::= { phiv 4 }
         routing                OBJECT IDENTIFIER ::= { phiv 5 }
         circuit                OBJECT IDENTIFIER ::= { phiv 6 }
         ddcmp                  OBJECT IDENTIFIER ::= { phiv 7 }
         control                OBJECT IDENTIFIER ::= { phiv 8 }
         ethernet               OBJECT IDENTIFIER ::= { phiv 9 }
         counters               OBJECT IDENTIFIER ::= { phiv 10 }
         adjacency              OBJECT IDENTIFIER ::= { phiv 11 }
         line                   OBJECT IDENTIFIER ::= { phiv 12 }
         nonBroadcastLine       OBJECT IDENTIFIER ::= { phiv 14 }
         area                   OBJECT IDENTIFIER ::= { phiv 15 }
   -- System Group
   -- The implementation of the System Group is mandatory for
   -- all systems.
   phivSystemState OBJECT-TYPE
        SYNTAX INTEGER {
            on (1),
            off (2),
            shut (3),
            restricted (4)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This represents the operational state of the executor
            node.
            The possible states are:
            ON          Allows logical links.
            OFF         Allows no new links, terminates existing
                        links, and stops routing traffic through.
            SHUT        Allows no new logical links, does not
                        destroy existing logical links, and goes
                        to the OFF state when all logical links are
                        gone.
            RESTRICTED  Allows no new incoming logical links from
                        other nodes.
            NOTE: These values are incremented by one compared to
            the standard DECnet values in order to maintain
            compliance with RFC 1155)."
        ::= { phivSystem 1 }
   phivExecIdent OBJECT-TYPE
       SYNTAX DisplayString ( SIZE (0..32) )
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This is a text string that describes the executor node
           (for example, 'Research Lab').  The string is up to 32
           characters of any type."
       ::= { phivSystem 2 }
   -- Network Management Group
   -- The implementation of the Network Management Group is
   -- mandatory for all systems which contain a DECnet style
   -- management version.
   phivMgmtMgmtVers OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..255) )
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This is the read-only Network Management Version,
            consisting of the version number, the Engineering
            Change Order (ECO) number, and the user ECO number
            (for example, 3.0.0). This parameter applies to the
            executor node only."
        ::= { phivManagement 1 }
   -- Session Layer Group
   -- The implementation of the Session Layer Group is mandatory for
   -- all systems that implement session layer communications.
   phivSessionSystemName OBJECT-TYPE
       SYNTAX DisplayString ( SIZE (0..6) )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Name to be associated with the node identification.
           Only one name can be assigned to a node address or a
           circuit identification. No name should be used more than
           once in a DECnet network. Node-name is one to six upper
           case alphanumeric characters with at least one alpha
           character. A length of 0 indicates no name."
       ::= { session 1 }
   phivSessionInTimer OBJECT-TYPE
       SYNTAX INTEGER (0..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum duration between the
           time a connect is received for a process at the
           executor node and the time that process accepts or
           rejects it. If the connect is not accepted or rejected
           by the user within the number of seconds specified,
           Session Control rejects it for the user.  A 0
           indicates no timer is running."
       ::= { session 2 }
   phivSessionOutTimer OBJECT-TYPE
       SYNTAX INTEGER (0..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the duration between the time the
           executor requests a connect and the time that connect is
           acknowledged by the destination node. If the connect is
           not acknowledged within the number of seconds
           specified, Session Control returns an error.  A 0
           indicates no timer is running."
       ::= { session 3 }
   -- End Communication Layer Group
   -- The implementation of the End Communication Layer Group is
   -- mandatory for all systems that implement end layer
   -- communications.
   -- Remote State Table
   phivEndRemoteTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivEndRemoteEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Information about the state of sessions between the
           node under study and the nodes found in the table."
       ::= { end 1 }
   phivEndRemoteEntry OBJECT-TYPE
       SYNTAX PhivEndRemoteEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Information about a particular remote node as seen
           from the end communication layer."
       INDEX  { phivEndRemoteHostNodeID }
       ::= { phivEndRemoteTable 1 }
   PhivEndRemoteEntry ::=
       SEQUENCE {
           phivEndRemoteHostNodeID
               PhivAddr,
           phivEndRemoteState
               INTEGER,
           phivEndCircuitIndex
               INTEGER,
           phivEndActiveLinks
               INTEGER,
           phivEndDelay
               INTEGER (0..65535)
        }
    phivEndRemoteHostNodeID OBJECT-TYPE
       SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value is the address of the remote node to be
           evaluated."
       ::= { phivEndRemoteEntry 1 }
   phivEndRemoteState OBJECT-TYPE
       SYNTAX INTEGER {
           on (1),
           off (2),
           shut (3),
           restricted (4)
       }
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This represents the operational state of the remote node
           being evaluated.
           The possible states are:
           ON          Allows logical links.
           OFF         Allows no new links, terminates existing
                       links, and stops routing traffic through.
           SHUT        Allows no new logical links, does not
                       destroy existing logical links, and goes
                       to the OFF state when all logical links are
                       gone.
           RESTRICTED  Allows no new incoming logical links from
                       other nodes.
           NOTE: These values are incremented by one compared to
           the standard DECnet values in order to maintain
           compliance with RFC 1155."
       ::= { phivEndRemoteEntry 2 }
   phivEndCircuitIndex OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "A unique index value for each known circuit used to
           communicate with the remote node.  This is the same
           value as phivCircuitIndex."
       ::= { phivEndRemoteEntry 3 }
   phivEndActiveLinks OBJECT-TYPE
       SYNTAX INTEGER (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This read-only parameter represents the number of active
           logical links from the executor to the destination node."
       ::= { phivEndRemoteEntry 4 }
   phivEndDelay OBJECT-TYPE
       SYNTAX INTEGER (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This read-only parameter is the average round trip
           delay in seconds to the destination node. This
           parameter is kept on a remote node basis."
       ::= { phivEndRemoteEntry 5 }
   -- End System Counter Table
   phivEndCountTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivEndCountEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Information about the counters associated with each end
           system that is known to the entity. These counters
           reflect totals from the perspective of the executor
           node."
       ::= { end 2 }
   phivEndCountEntry OBJECT-TYPE
       SYNTAX PhivEndCountEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Information about a particular session between two end
           systems."
       INDEX  { phivEndCountHostNodeID }
       ::= { phivEndCountTable 1 }
   PhivEndCountEntry ::=
       SEQUENCE {
           phivEndCountHostNodeID
               PhivAddr,
           phivEndCountSecsLastZeroed
               PhivCounter (0..65535),
           phivEndCountUsrBytesRec
               PhivCounter,
           phivEndCountUsrBytesSent
               PhivCounter,
           phivEndUCountUsrMessRec
               PhivCounter,
           phivEndCountUsrMessSent
               PhivCounter,
           phivEndCountTotalBytesRec
               PhivCounter,
           phivEndCountTotalBytesSent
               PhivCounter,
           phivEndCountTotalMessRec
               PhivCounter,
           phivEndCountTotalMessSent
               PhivCounter,
           phivEndCountConnectsRecd
               PhivCounter (0..65535),
           phivEndCountConnectsSent
               PhivCounter (0..65535),
           phivEndCountReponseTimeouts
               PhivCounter (0..65535),
           phivEndCountRecdConnectResErrs
               PhivCounter (0..65535)
       }
   phivEndCountHostNodeID OBJECT-TYPE
       SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value is the address of the remote node to be
           evaluated."
       ::= { phivEndCountEntry 1 }
   phivEndCountSecsLastZeroed OBJECT-TYPE
       SYNTAX PhivCounter (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value is the number of seconds that have elapsed
           since the counters for the node in this table row were
           last set to zero. This counter is located  in the
           network management layer, but is returned with the
           end system information which follows."
       ::= { phivEndCountEntry 2 }
   phivEndCountUsrBytesRec OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of user bytes received from the target host."
       ::= { phivEndCountEntry 3 }
   phivEndCountUsrBytesSent OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of user bytes sent to the target host."
       ::= { phivEndCountEntry 4 }
   phivEndUCountUsrMessRec OBJECT-TYPE
        SYNTAX PhivCounter
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of user messages received from the target host."
        ::= { phivEndCountEntry 5 }
   phivEndCountUsrMessSent OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of user messages sent to the target host."
       ::= { phivEndCountEntry 6 }
   phivEndCountTotalBytesRec OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of bytes received from the target host."
       ::= { phivEndCountEntry 7 }
   phivEndCountTotalBytesSent OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of bytes sent to the target host."
       ::= { phivEndCountEntry 8 }
   phivEndCountTotalMessRec OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of messages received from the target host."
       ::= { phivEndCountEntry 9 }
   phivEndCountTotalMessSent OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of messages sent to the target host."
       ::= { phivEndCountEntry 10 }
   phivEndCountConnectsRecd OBJECT-TYPE
       SYNTAX PhivCounter (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of connects received from the target host."
       ::= { phivEndCountEntry 11 }
   phivEndCountConnectsSent OBJECT-TYPE
       SYNTAX PhivCounter (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of connects sent to the target host."
       ::= {phivEndCountEntry 12 }
   phivEndCountReponseTimeouts OBJECT-TYPE
       SYNTAX PhivCounter (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of response timeouts."
       ::= { phivEndCountEntry 13 }
   phivEndCountRecdConnectResErrs OBJECT-TYPE
       SYNTAX PhivCounter (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of received connect resource errors."
       ::= {phivEndCountEntry 14 }
   -- additional End System objects
   phivEndMaxLinks OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum active logical
           link count allowed for the executor."
       ::= { end 3 }
   phivEndNSPVers OBJECT-TYPE
       SYNTAX DisplayString (SIZE (0..255) )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This read-only parameter represents the version number
           of the node End Communication S/W. The format is
           version number, ECO, and user ECO, e.g., 4.1.0"
       ::= { end 4 }
   phivEndRetransmitFactor OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum number of times the
           source End Communication at the executor node will
           restart the retransmission timer when it expires. If
           the number is exceeded, Session Control disconnects the
           logical link for the user."
       ::= { end 5 }
   phivEndDelayFact OBJECT-TYPE
       SYNTAX INTEGER (1..255)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This is the number by which to multiply one sixteenth
           of the estimated round trip delay to a node to set the
           retransmission timer to that node."
       ::= { end 6 }
   phivEndDelayWeight OBJECT-TYPE
       SYNTAX INTEGER (1..255)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This number represents the weight to apply to a
           current round trip delay estimate to a remote node
           when updating the estimated round trip delay to a node.
           On some systems the number must be 1 less than a power
           of 2 for computational efficiency."
       ::= { end 7 }
   phivEndInactivityTimer OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum duration of inactivity
           (no data in either direction) on a logical link before
           the node checks to see if the logical link still works.
           If no activity occurs within the minimum number of
           seconds, End Communication generates artificial
           traffic to test the link (End Communication
           specification)."
       ::= { end 8 }
   phivEndCountZeroCount OBJECT-TYPE
       SYNTAX INTEGER {
         other (1),
         reset (2)
       }
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "When this value is set to 2, all of the counters in
           the End System Counter Table are set to zero."
       ::= { end 9 }
   phivEndMaxLinksActive OBJECT-TYPE
       SYNTAX PhivCounter (0..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the high water mark for the
           number of links that were active at any one time."
       ::= { end 10 }
   -- Routing Layer Group
   -- The implementation of the Routing Layer Group is mandatory for
   -- all systems that implement level 1 routing layer
   -- communications.
   phivRouteBroadcastRouteTimer OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value determines the maximum time in seconds
            allowed between Routing updates on Ethernet
            circuits. When this timer expired before a routing
            update occurs, a routing update is forced.  With a
            standard calculation, Routing also uses this timer
            to enforce a minimum delay between routing updates."
       ::= { routing 1 }
   phivRouteBuffSize OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This parameter value determines the maximum size of
            a Routing message. It therefore determines the maximum
            size message that can be forwarded.  This size includes
            protocol overhead down to and including the End
            Communication layer, plus a constant value of 6. (This
            value of 6 is included to provide compatibility with
            the parameter definition in Phase III, which included
            the Routing overhead.) It does not include Routing or
            Data link overhead (except for the constant value of
            6). There is one buffer size for all circuits.
            NOTE: The BUFFER SIZE defines the maximum size messages
            that the Routing layer can forward. The SEGMENT BUFFER
            SIZE (defined below) defines the maximum size messages
            that the End Communication layer can transmit or
            receive. The SEGMENT BUFFER SIZE is always less than
            or equal to the BUFFER SIZE. Normally the two
            parameters will be equal. They may be different to
            allow the network manager to alter buffer sizes
            on all nodes without interruption of service. They both
            include an extra 6 bytes for compatibility with Phase
            III."
       ::= { routing 2 }
   phivRouteRoutingVers OBJECT-TYPE
       SYNTAX DisplayString ( SIZE (0..255) )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This read-only parameter identifies the executor node's
           Routing version number.  The format is version number,
           ECO, and user ECO, e.g., 4.1.0"
       ::= { routing 3 }
   phivRouteMaxAddr OBJECT-TYPE
       SYNTAX INTEGER (1..1023)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the largest node number and,
           therefore, number of nodes that can be known about
           by the executor node's home area."
       ::= { routing 4 }
   phivRouteMaxBdcastNonRouters OBJECT-TYPE
       SYNTAX INTEGER (0..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum total number of
           nonrouters the executor node can have on its Ethernet
           circuits."
       ::= { routing 5 }
   phivRouteMaxBdcastRouters OBJECT-TYPE
       SYNTAX INTEGER (0..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum total number of
           routers the executor node can have on its Ethernet
           circuits."
       ::= { routing 6 }
   phivRouteMaxBuffs OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum number of transmit
           buffers that Routing may use for all circuits."
       ::= { routing 7 }
   phivRouteMaxCircuits OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum number of Routing
           circuits that the executor node can know about."
       ::= { routing 8 }
   phivRouteMaxCost OBJECT-TYPE
       SYNTAX INTEGER (1..1022)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum total path cost
           allowed from the executor to any node within an area.
           The path cost is the sum of the circuit costs along
           a path between two nodes. This parameter defines the
           point where the executor node's Routing routing
           decision algorithm declares another node unreachable
           because the cost of the least costly path to the
           other node is excessive. For correct operation, this
           parameter must not be less than the maximum path cost
           of the network."
       ::= { routing 9 }
   phivRouteMaxHops OBJECT-TYPE
       SYNTAX INTEGER (1..30)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum number of routing hops
           allowable from the executor to any other reachable node
           within an area. (A hop is the logical distance over a
           circuit between two adjacent nodes.) This parameter
           defines the point where the executor node's Routing
           routing decision algorithm declares another node
           unreachable because the length of the shortest path
           between the two nodes is too long. For correct
           operation, this parameter must not be less than the
           network diameter. (The network diameter is the
           reachability distance between the two nodes of the
           network having the greatest reachability distance,
           where reachability distance is the length the shortest
           path between a given pair of nodes.)"
       ::= { routing 10 }
   phivRouteMaxVisits OBJECT-TYPE
       SYNTAX INTEGER (1..63)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum number of nodes a
           message coming into the executor node can have visited.
           If the message is not for this node and the MAXIMUM
           VISITS number is exceeded, the message is discarded.
           The MAXIMUM VISITS parameter defines the point where
           the packet lifetime control algorithm discards
           a packet that has traversed too many nodes. For correct
           operation, this parameter must not be less than the
           maximum path length of the network. (The maximum path
           length is the routing distance between the two nodes of
           the network having the greatest routing distance, where
           routing distance is the length of the least costly
           path between a given pair of nodes.)"
       ::= { routing 11 }
   phivRouteRoutingTimer OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value determines the maximum time in seconds
           allowed between Routing updates on non-Ethernet
           circuits. When this timer expires before a routing
           update occurs, a routing update is forced."
       ::= { routing 12 }
   phivRouteSegBuffSize OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This parameter value determines the maximum size of an
           end-to-end segment. The size is a decimal integer in
           the range 1-65535. This size is in bytes. This size
           includes protocol overhead down to and including the
           End Communication layer, plus a constant value of 6.
           (This value of 6 is included to provide compatibility
           with the BUFFER SIZE parameter definition.) It does not
           include Routing or Data link overhead (except for the
           constant value of 6)."
       ::= { routing 13 }
   phivRouteType OBJECT-TYPE
       SYNTAXINTEGER {
           routing-III (1),
           nonrouting-III (2),
           area (3),
           routing-IV (4),
           nonrouting-IV (5)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This parameter indicates the type of the executor
           node. The node-type is one of the following:
           routing-III
           nonrouting-III
           routing-IV
           ronrouting-IV
           area
           A routing node has full routing capability. A
           nonrouting node contains a subset of the Routing
           routing modules. The III and IV indicate the DNA
           phase of the node. Nonrouting nodes can deliver
           and receive packets to and from any node, but cannot
           route packets from other nodes through to other nodes.
           An area node routes between areas. Refer to the Routing
           specification for details.
           For adjacent nodes, this is a read-only parameter that
           indicates the type of the reachable adjacent node.
           NOTE: The ROUTING-III and NONROUTING-III values are
           incremented by one compared to the standard DECnet
           values in order to maintain compliance with RFC 1155)"
       ::= { routing 14 }
   phivRouteCountAgedPktLoss OBJECT-TYPE
       SYNTAX PhivCounter (0..127)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of aged packet losses."
       ::= { routing 15 }
   phivRouteCountNodeUnrPktLoss OBJECT-TYPE
       SYNTAX PhivCounter (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of node unreachable packet losses."
       ::= { routing 16 }
   phivRouteCountOutRngePktLoss OBJECT-TYPE
       SYNTAX PhivCounter (0..127)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of node out-of-range packet losses."
       ::= { routing 17 }
   phivRouteCountOverSzePktLoss OBJECT-TYPE
       SYNTAX PhivCounter (0..127)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of Oversized packet losses."
       ::= { routing 18 }
   phivRouteCountPacketFmtErr OBJECT-TYPE
       SYNTAX PhivCounter (0..127)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of packet format errors."
       ::= { routing 19 }
   phivRouteCountPtlRteUpdtLoss OBJECT-TYPE
       SYNTAX PhivCounter (0..127)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of partial routing update losses."
       ::= { routing 20 }
   phivRouteCountVerifReject OBJECT-TYPE
       SYNTAX PhivCounter (0..127)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of verification rejects."
       ::= { routing 21 }
    -- Level 1 Routing Table
   phivLevel1RouteTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivLevel1RouteEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Information about the currently known DECnet Phase
           IV Routes."
       ::= { routing 22 }
   phivLevel1RouteEntry OBJECT-TYPE
       SYNTAX PhivLevel1RouteEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Information about the currently known DECnet Phase
           IV Routes."
       INDEX  { phivLevel1RouteNodeAddr }
       ::= { phivLevel1RouteTable 1 }
   PhivLevel1RouteEntry ::=
       SEQUENCE {
           phivLevel1RouteNodeAddr
               PhivAddr,
           phivLevel1RouteCircuitIndex
               INTEGER,
           phivLevel1RouteCost
               INTEGER (0..65535),
           phivLevel1RouteHops
               INTEGER (0..127),
           phivLevel1RouteNextNode
               PhivAddr
            }
    phivLevel1RouteNodeAddr OBJECT-TYPE
       SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value is the address of the node about which
           routing information is contained in this level 1
           routing table."
       ::= { phivLevel1RouteEntry 1 }
   phivLevel1RouteCircuitIndex OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "A unique index value for each known circuit. This is
           the index to the circuit state table and is the same
           value as phivCircuitIndex."
       ::= { phivLevel1RouteEntry 2 }
   phivLevel1RouteCost OBJECT-TYPE
       SYNTAX INTEGER (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This read-only parameter represents the total cost
           over the current path to the destination node. Cost is
           a positive integer value associated with using a
           circuit. Routing routes messages (data) along the path
           between two nodes with the smallest cost. COST is kept
           on a remote node basis."
       ::= { phivLevel1RouteEntry 3 }
   phivLevel1RouteHops OBJECT-TYPE
       SYNTAX INTEGER (0..127)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This read-only parameter represents the number of hops
           over to a destination node. A hop is Routing value
           representing the logical distance between two nodes in
           a network. HOPS is kept on a remote node basis."
       ::= { phivLevel1RouteEntry 4 }
   phivLevel1RouteNextNode OBJECT-TYPE
       SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This read-only value indicates the next node on the
           circuit used to get to the node under scrutiny
           (next hop)."
       ::= { phivLevel1RouteEntry 5 }
   -- Additional routing parameters
   phivRouteCountZeroCount OBJECT-TYPE
       SYNTAX INTEGER {
         other (1),
         reset (2)
       }
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "When this value is set to 2, the following objects are
           set to Zero: phivRouteCountAgedPktLoss,
           phivRouteCountNodeUnrPktLoss,
           phivRouteCountOutRngePktLoss,
           phivRouteCountOverSzePktLoss,
           phivRouteCountPacketFmtErr,
           phivRouteCountPtlRteUpdtLoss, and
           phivRouteCountVerifReject."
       ::= { routing 23 }
   phivRouteSystemAddr OBJECT-TYPE
       SYNTAX PhivAddr
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "DECnet Phase IV node address."
       ::= { routing 24 }
   -- Circuit Group
   -- The implementation of the Circuit Group is mandatory for
   -- all systems.
   -- Circuit Parameters Table
   phivCircuitParametersTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivCircuitParametersEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Information about the parameters associated with all
           circuits currently known."
       ::= {circuit 1 }
   phivCircuitParametersEntry OBJECT-TYPE
       SYNTAX PhivCircuitParametersEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Parameters information about all circuits currently
           known."
        INDEX  { phivCircuitIndex }
        ::= { phivCircuitParametersTable 1 }
   PhivCircuitParametersEntry ::=
       SEQUENCE {
           phivCircuitIndex
               INTEGER,
           phivCircuitLineIndex
               INTEGER,
           phivCircuitCommonState
               INTEGER,
           phivCircuitCommonSubState
               INTEGER,
           phivCircuitCommonName
               DisplayString,
           phivCircuitExecRecallTimer
               INTEGER (0..65535),
           phivCircuitCommonType
               INTEGER,
           phivCircuitService
               INTEGER,
           phivCircuitExecCost
               INTEGER (1..25),
           phivCircuitExecHelloTimer
               INTEGER (1..8191)
       }
    phivCircuitIndex OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "A unique index value for each known circuit."
       ::= { phivCircuitParametersEntry 1 }
   phivCircuitLineIndex OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "The line on which this circuit is active.  This is
           the same as the IfIndex."
       ::= { phivCircuitParametersEntry 2 }
   phivCircuitCommonState OBJECT-TYPE
       SYNTAX INTEGER {
           on (1),
           off (2),
           service (3),
           cleared (4)
       }
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the circuit's Network Management
           operational state. NOTE: These values are incremented
           by one compared to the standard DECnet values in order
           to maintain compliance with RFC 1155."
       ::= { phivCircuitParametersEntry 3 }
   phivCircuitCommonSubState OBJECT-TYPE
       SYNTAX INTEGER {
           starting (1),
           reflecting (2),
           looping (3),
           loading (4),
           dumping (5),
           triggering (6),
           autoservice (7),
           autoloading (8),
           autodumping (9),
           autotriggering (10),
           synchronizing (11),
           failed (12),
           running (13)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the circuit's Network Management
           operational and service substate. NOTE: These values are
           incremented by one compared to the standard DECnet values
           in order to maintain compliance with RFC 1155."
       ::= { phivCircuitParametersEntry 4 }
   phivCircuitCommonName OBJECT-TYPE
       SYNTAX DisplayString ( SIZE (0..16) )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "The name of the circuit entry in the table, for example,
           SVA-0 or in a level 2 router ASYNC-8 or ETHER-1)."
       ::= { phivCircuitParametersEntry 5 }
   phivCircuitExecRecallTimer OBJECT-TYPE
       SYNTAX INTEGER (0..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This parameter represents the minimum number of
           seconds to wait before restarting the circuit.  A
           value of 0 indicates not timer is running."
       ::= { phivCircuitParametersEntry 6 }
   phivCircuitCommonType OBJECT-TYPE
       SYNTAX INTEGER {
           ddcmp-point (1),
           ddcmp-control (2),
           ddcmp-tributary (3),
           x25 (4),
           ddcmp-dmc (5),
           ethernet (6),
           ci (7),
           qp2-dte20 (8),
           bisync (9),
           other (14),
           fddi (15)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Represents the type of the circuit. For X.25 circuits,
           the value must be set to X25. For DDCMP and Ethernet
           circuits it is read only and is the same value as the
           protocol of the associated line.
           NOTE: Values 1 - 5 are incremented by one compared to the
           standard DECnet values in order to maintain compliance
           with RFC 1155."
       ::= { phivCircuitParametersEntry 7 }
   phivCircuitService  OBJECT-TYPE
       SYNTAX INTEGER {
           enabled (1),
           disabled (2)
       }
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value indicates whether or not Network Management
           allows service operations on a circuit. The values for
           service-control are as follows:
           ENABLED     SERVICE state and/or service functions are
                       allowed.
           DISABLED    SERVICE state and/or service functions are not
                       allowed.
           NOTE: These values are incremented by one compared to the
           standard DECnet values in order to maintain compliance
           with RFC 1155."
       ::= { phivCircuitParametersEntry 8 }
   phivCircuitExecCost OBJECT-TYPE
       SYNTAX INTEGER (1..25)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the routing cost of the circuit.
           Routing sends messages along the path between two nodes
           having the smallest cost."
       ::= { phivCircuitParametersEntry 9 }
   phivCircuitExecHelloTimer OBJECT-TYPE
       SYNTAX INTEGER (1..8191)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value determines the frequency of Routing Hello
           messages sent to the adjacent node on the circuit."
       ::= { phivCircuitParametersEntry 10 }
   -- Circuit Counters Table
   phivCircuitCountTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivCircuitCountEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Information about the counters associated with all
           circuits currently known."
       ::= { circuit 2 }
   phivCircuitCountEntry OBJECT-TYPE
       SYNTAX PhivCircuitCountEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Counter information about all circuits currently known"
       INDEX     { phivCircuitIndex }
       ::= { phivCircuitCountTable 1 }
   PhivCircuitCountEntry ::=
       SEQUENCE {
           phivCircuitCountSecLastZeroed
               PhivCounter (0..65535),
           phivCircuitCountTermPacketsRecd
               PhivCounter,
           phivCircuitCountOriginPackSent
               PhivCounter,
           phivCircuitCountTermCongLoss
               PhivCounter (0..65535),
           phivCircuitCountCorruptLoss
               PhivCounter (0..255),
           phivCircuitCountTransitPksRecd
               PhivCounter,
           phivCircuitCountTransitPkSent
               PhivCounter,
           phivCircuitCountTransitCongestLoss
               PhivCounter (0..65535),
           phivCircuitCountCircuitDown
               PhivCounter (0..255),
           phivCircuitCountInitFailure
               PhivCounter (0..255),
           phivCircuitCountAdjDown
               PhivCounter,
           phivCircuitCountPeakAdj
               PhivCounter,
           phivCircuitCountBytesRecd
               PhivCounter,
           phivCircuitCountBytesSent
               PhivCounter,
           phivCircuitCountDataBlocksRecd
               PhivCounter (0..65535),
           phivCircuitCountDataBlocksSent
               PhivCounter,
           phivCircuitCountUsrBuffUnav
               PhivCounter (0..65535)
       }
   phivCircuitCountSecLastZeroed  OBJECT-TYPE
       SYNTAX PhivCounter (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of seconds since the circuit counters for this
           circuit were last zeroed."
       ::= { phivCircuitCountEntry 1 }
   phivCircuitCountTermPacketsRecd OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of terminating packets received on this circuit."
       ::= { phivCircuitCountEntry 2 }
   phivCircuitCountOriginPackSent OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of originating packets sent on this circuit."
       ::= { phivCircuitCountEntry 3 }
   phivCircuitCountTermCongLoss OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of terminating congestion losses on this
           circuit."
       ::= { phivCircuitCountEntry 4 }
   phivCircuitCountCorruptLoss OBJECT-TYPE
       SYNTAX PhivCounter (0..255)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of corruption losses on this circuit."
       ::= { phivCircuitCountEntry 5 }
   phivCircuitCountTransitPksRecd OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of Transit packets received on this circuit."
       ::= { phivCircuitCountEntry 6 }
   phivCircuitCountTransitPkSent OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of transit packets sent on this circuit."
       ::= { phivCircuitCountEntry 7 }
   phivCircuitCountTransitCongestLoss OBJECT-TYPE
       SYNTAX PhivCounter (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of transit congestion losses on this circuit."
       ::= { phivCircuitCountEntry 8 }
   phivCircuitCountCircuitDown OBJECT-TYPE
       SYNTAX PhivCounter (0..255)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of circuit downs on this circuit."
       ::= { phivCircuitCountEntry 9 }
   phivCircuitCountInitFailure OBJECT-TYPE
       SYNTAX PhivCounter (0..255)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of Initialization failures on this circuit."
       ::= { phivCircuitCountEntry 10 }
   phivCircuitCountAdjDown OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This counter indicates the number of adjacency losses
           that result from any of the following:
                Node listener timeout
                Invalid data received at node listener
                Unexpected control (initialization or verification)
                    message received
                Routing message received with a checksum error
                Node identification from a routing message or a
                Hello message that is not the one expected Hello
                message received indicating that connectivity
                became one-way
                Adjacency idled."
       ::= { phivCircuitCountEntry 11 }
   phivCircuitCountPeakAdj OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This counter indicates the maximum number of nodes
           that are up on the circuit."
       ::= { phivCircuitCountEntry 12 }
   phivCircuitCountBytesRecd OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of bytes received on this circuit."
       ::= { phivCircuitCountEntry 13 }
   phivCircuitCountBytesSent OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of bytes sent on this circuit."
       ::= { phivCircuitCountEntry 14 }
   phivCircuitCountDataBlocksRecd OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of data blocks received on this circuit."
       ::= { phivCircuitCountEntry 15 }
   phivCircuitCountDataBlocksSent OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of data blocks sent on this circuit."
       ::= { phivCircuitCountEntry 16 }
   phivCircuitCountUsrBuffUnav OBJECT-TYPE
       SYNTAX PhivCounter (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of user buffer unavailable errors."
       ::= { phivCircuitCountEntry 17 }
   -- Additional Circuit Parameters
   phivCircuitOrigQueueLimit OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This parameter indicates the maximum number of
           originating packets that may be outstanding on this
           circuit. This does not include route-thru traffic."
       ::= { circuit 3 }
   phivCircuitCountZeroCount OBJECT-TYPE
       SYNTAX INTEGER {
         other (1),
         reset (2)
       }
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "When this value is set to 2, all of the counters in the
           Circuit Counter Table are set to zero."
       ::= { circuit 4 }
   -- DDCMP Circuit Group
   -- The implementation of the DDCMP Circuit Group is mandatory for
   -- all systems which support DDCMP circuits.
   -- DDCMP Parameters Table
   phivDDCMPCircuitParametersTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivDDCMPCircuitParametersEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Information about DDCMP circuit parameters."
       ::= { ddcmp 1}
   phivDDCMPCircuitParametersEntry OBJECT-TYPE
       SYNTAX PhivDDCMPCircuitParametersEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Parameters information about DDCMP circuits currently
            known."
       INDEX     { phivDDCMPCircuitIndex }
       ::= { phivDDCMPCircuitParametersTable 1 }
   PhivDDCMPCircuitParametersEntry ::=
       SEQUENCE {
           phivDDCMPCircuitIndex
               INTEGER,
           phivDDCMPCircuitAdjNodeAddr
               INTEGER (0..65535),
           phivDDCMPCircuitTributary
               INTEGER (0..255)
       }
   phivDDCMPCircuitIndex OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "A unique index value for each known DDCMP circuit.
           This is the same value as phivCircuitIndex."
       ::= { phivDDCMPCircuitParametersEntry 1 }
   phivDDCMPCircuitAdjNodeAddr OBJECT-TYPE
       SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "The address of the adjacent node."
       ::= { phivDDCMPCircuitParametersEntry 2 }
   phivDDCMPCircuitTributary OBJECT-TYPE
       SYNTAX INTEGER (0..255)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the Data Link physical tributary
           address of the circuit."
       ::= { phivDDCMPCircuitParametersEntry 3 }
   -- DDCMP Circuit Counter Table
   phivDDCMPCircuitCountTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivDDCMPCircuitCountEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Information about the DDCMP counters associated with all
           circuits currently known."
       ::= { ddcmp 2 }
   phivDDCMPCircuitCountEntry OBJECT-TYPE
       SYNTAX PhivDDCMPCircuitCountEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Counter information about DDCMP circuits now known"
       INDEX     { phivCircuitIndex }
       ::= { phivDDCMPCircuitCountTable 1 }
   PhivDDCMPCircuitCountEntry ::=
       SEQUENCE {
           phivDDCMPCircuitErrorsInbd
               PhivCounter (0..255),
           phivDDCMPCircuitErrorsOutbd
               PhivCounter (0..255),
           phivDDCMPCircuitRmteReplyTimeouts
               PhivCounter (0..255),
           phivDDCMPCircuitLocalReplyTimeouts
               PhivCounter (0..255),
           phivDDCMPCircuitRmteBuffErrors
               PhivCounter (0..255),
           phivDDCMPCircuitLocalBuffErrors
               PhivCounter (0..255),
           phivDDCMPCircuitSelectIntervalsElap
               PhivCounter (0..65535),
           phivDDCMPCircuitSelectTimeouts
               PhivCounter (0..255)
       }
   phivDDCMPCircuitErrorsInbd OBJECT-TYPE
       SYNTAX PhivCounter (0..255)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of Data errors inbound."
       ::= { phivDDCMPCircuitCountEntry 1 }
   phivDDCMPCircuitErrorsOutbd OBJECT-TYPE
       SYNTAX PhivCounter (0..255)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of outbound data errors."
       ::= { phivDDCMPCircuitCountEntry 2 }
   phivDDCMPCircuitRmteReplyTimeouts OBJECT-TYPE
       SYNTAX PhivCounter (0..255)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of remote reply timeouts."
       ::= { phivDDCMPCircuitCountEntry 3 }
   phivDDCMPCircuitLocalReplyTimeouts OBJECT-TYPE
       SYNTAX PhivCounter (0..255)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of local Reply timeouts."
       ::= { phivDDCMPCircuitCountEntry 4 }
   phivDDCMPCircuitRmteBuffErrors OBJECT-TYPE
       SYNTAX PhivCounter (0..255)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of remote reply time out errors."
       ::= { phivDDCMPCircuitCountEntry 5 }
   phivDDCMPCircuitLocalBuffErrors  OBJECT-TYPE
       SYNTAX PhivCounter (0..255)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of local buffer errors."
       ::= { phivDDCMPCircuitCountEntry 6 }
   phivDDCMPCircuitSelectIntervalsElap OBJECT-TYPE
       SYNTAX PhivCounter (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Selection intervals that have elapsed."
       ::= {phivDDCMPCircuitCountEntry 7 }
   phivDDCMPCircuitSelectTimeouts OBJECT-TYPE
       SYNTAX INTEGER (0..255)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of selection timeouts."
       ::= {phivDDCMPCircuitCountEntry 8 }
   -- DDCMP Line Count Table
   phivDDCMPLineCountTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivDDCMPLineCountEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "The DDCMP Line Count Table."
       ::= { ddcmp 3 }
   phivDDCMPLineCountEntry OBJECT-TYPE
       SYNTAX PhivDDCMPLineCountEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "There is one entry in the table for each line."
       INDEX  { phivDDCMPLineCountIndex }
       ::= { phivDDCMPLineCountTable 1 }
   PhivDDCMPLineCountEntry ::=
       SEQUENCE {
           phivDDCMPLineCountIndex
               INTEGER,
           phivDDCMPLineCountDataErrsIn
               PhivCounter (0..255),
           phivDDCMPLineCountRmteStationErrs
               PhivCounter (0..255),
           phivDDCMPLineCountLocalStationErrs
               PhivCounter (0..255)
       }
   phivDDCMPLineCountIndex OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "The line on which this entry's equivalence is
           effective. The interface identified by a particular
           value of this index is the same interface as
           identified by the same value of phivLineIndex.
           This value is the IfIndex."
       ::= { phivDDCMPLineCountEntry 1 }
   phivDDCMPLineCountDataErrsIn OBJECT-TYPE
       SYNTAX PhivCounter ( 0..255 )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of data errors inbound."
       ::= { phivDDCMPLineCountEntry 2 }
   phivDDCMPLineCountRmteStationErrs OBJECT-TYPE
       SYNTAX PhivCounter ( 0..255 )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of remote station errors."
       ::= { phivDDCMPLineCountEntry 3 }
   phivDDCMPLineCountLocalStationErrs OBJECT-TYPE
       SYNTAX PhivCounter ( 0..255 )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
            "Number of local station errors."
       ::= { phivDDCMPLineCountEntry 4 }
   -- DDCMP Multipoint Circuit Control Group
   -- The implementation of the DDCMP Multipoint Circuit Control
   -- Group is mandatory for all systems which support DDCMP
   -- multipoint control circuits.
   phivControlSchedTimer OBJECT-TYPE
       SYNTAX INTEGER (50..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the number of milliseconds
           between recalculation of tributary polling priorities."
       DEFVAL { 200 }
       ::= { control 1 }
   phivControlDeadTimer OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the number of milliseconds
           between polls of one of the set of dead
           tributaries."
       DEFVAL { 10000 }
       ::= { control 2 }
   phivControlDelayTimer OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the minimum number of
           milliseconds to delay between polls. The delay timer
           limits the effect of a very fast control station on
           slow tributaries."
       ::= { control 3 }
   phivControlStreamTimer OBJECT-TYPE
       SYNTAX INTEGER (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the number of milliseconds a
           tributary or a half duplex remote station is
           allowed to hold the line.
           NOTE: This parameter can also be applied to
           half-duplex lines of type DDCMP POINT."
       DEFVAL { 6000 }
       ::= { control 4 }
   -- DDCMP Multipoint Circuit Control Parameters Table
   phivControlParametersTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivControlParametersEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Information about control circuit parameters."
       ::= { control 5 }
   phivControlParametersEntry OBJECT-TYPE
       SYNTAX PhivControlParametersEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Parameters information about control circuits
           currently known."
       INDEX  { phivControlCircuitIndex }
       ::= { phivControlParametersTable 1 }
   PhivControlParametersEntry ::=
       SEQUENCE {
           phivControlCircuitIndex
               INTEGER,
           phivControlBabbleTimer
               INTEGER (1..65535),
           phivControlMaxBuffs
               INTEGER (0..254),
           phivControlMaxTransmits
               INTEGER (1..255),
           phivControlDyingBase
               INTEGER (0..255),
           phivControlDyingIncrement
               INTEGER (0..255),
           phivControlDeadThreshold
               INTEGER (0..255),
           phivControlDyingThreshold
               INTEGER (0..255),
           phivControlInactTreshold
               INTEGER (0..255),
           phivControlPollingState
               INTEGER,
           phivControlPollingSubState
               INTEGER,
           phivControlTransTimer
               INTEGER (0..65535)
       }
   phivControlCircuitIndex OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "A unique index value for each known multirpoint
           control circuit.
            This is the same value as phivCircuitIndex."
       ::= { phivControlParametersEntry 1 }
   phivControlBabbleTimer OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the number of milliseconds that a
           selected tributary or remote half-duplex station is
           allowed to transmit."
       DEFVAL { 6000 }
       ::= { phivControlParametersEntry 2 }
   phivControlMaxBuffs  OBJECT-TYPE
       SYNTAX INTEGER (0..254)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum number of buffers the
           tributary can use from a common buffer pool. If not
           set, there is no common buffer pool and buffers are
           explicitly supplied by the higher level. Count is a
           decimal integer in the range 1-254."
       ::= { phivControlParametersEntry 3 }
   phivControlMaxTransmits  OBJECT-TYPE
       SYNTAX INTEGER (1..255)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum number of data
           messages that can be transmitted at one time. Count
           is a decimal integer in the range 1-255."
       DEFVAL { 4 }
       ::= { phivControlParametersEntry 4 }
   phivControlDyingBase OBJECT-TYPE
       SYNTAX INTEGER (0..255)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the base priority to which a
           tributary is reset each time it has been polled. A
           separate base can be set for each of the indicated
           polling states. Base is a decimal integer in the range
           0-255.  If not set, the defaults are: active, 255;
           inactive, 0; and dying, 0."
       ::= { phivControlParametersEntry 5 }
   phivControlDyingIncrement OBJECT-TYPE
       SYNTAX INTEGER (0..255)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the increment added to the
           tributary priority each time the scheduling timer
           expires.  If not set, the defaults are: active, 0;
           inactive, 64; and dying, 16."
       ::= { phivControlParametersEntry 6 }
   phivControlDeadThreshold OBJECT-TYPE
       SYNTAX INTEGER (0..255)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the number of times to poll the
           active, inactive, or dying tributary before changing
           its polling state to dead because of receive timeouts.
           Count is a decimal integer in the range 0-255."
       DEFVAL { 8 }
       ::= { phivControlParametersEntry 7 }
   phivControlDyingThreshold OBJECT-TYPE
       SYNTAX INTEGER (0..255)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the number of times to poll the
           active or inactive tributary before changing its
           polling state to dying because of receive timeouts.
           Count is a decimal integer in the range 0-255."
       DEFVAL { 2 }
       ::= { phivControlParametersEntry 8 }
   phivControlInactTreshold OBJECT-TYPE
       SYNTAX INTEGER (0..255)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the number of times to poll the
           active tributary before changing its polling state to
           inactive because of no data response. Count is a
           decimal integer in the range
           0-255."
       DEFVAL { 8 }
       ::= { phivControlParametersEntry 9 }
   phivControlPollingState OBJECT-TYPE
       SYNTAX INTEGER {
           automatic (1),
           active (2),
           inactive (3),
           dying (4),
           dead (5)
       }
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the state of the tributary
           relative to the multipoint polling algorithm.  If not
           set the default is AUTOMATIC. The possible states are:
           AUTOMATIC
             The tributary's state is allowed to vary according to
             the operation of the polling algorithm.
           ACTIVE/INACTIVE/DYING/DEAD
             The tributary is locked in the specified state.
            NOTE: These values are incremented by one compared to
            the standard DECnet values in order to maintain
            compliance with RFC 1155."
       ::= { phivControlParametersEntry 10 }
   phivControlPollingSubState OBJECT-TYPE
       SYNTAX INTEGER {
           active (1),
           inactive (2),
           dying (3),
           dead (4)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the tributary's state as
           determined by the polling algorithm.  This applies
           only when the polling state is AUTOMATIC and is
           read-only to Network Management.  Polling-substate is
           one of ACTIVE, INACTIVE, DYING, or DEAD.  It is
           displayed as a tag on the polling state, for example:
           AUTOMATIC-INACTIVE."
       ::= { phivControlParametersEntry 11 }
   phivControlTransTimer OBJECT-TYPE
       SYNTAX INTEGER (0..65535)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the number of milliseconds to
           delay between data message transmits. Milliseconds is
           a decimal integer in the range 0-65535."
       DEFVAL { 0 }
       ::= { phivControlParametersEntry 12 }
   -- Ethernet Group
   -- The implementation of the Ethernet Group is mandatory
   -- for all systems which support ethernet links.
   -- Ethernet Parameters Table
   phivEthLinkParametersTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivEthLinkParametersEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Information about ethernet link parameters."
       ::= { ethernet 1}
   phivEthLinkParametersEntry OBJECT-TYPE
       SYNTAX PhivEthLinkParametersEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Parameter information about ethernet links currently
           known."
       INDEX     { phivEthLinkIndex }
       ::= { phivEthLinkParametersTable 1 }
   PhivEthLinkParametersEntry ::=
       SEQUENCE {
           phivEthLinkIndex
               INTEGER,
           phivEthDesigRouterNodeAddr
               PhivAddr,
           phivEthMaxRouters
               INTEGER (0..255),
           phivEthRouterPri
               INTEGER (0..127),
           phivEthHardwareAddr
               OCTET STRING
        }
   phivEthLinkIndex OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "The circuit over which this links information is
           collected.  This is the same as phivCircuitIndex."
       ::= { phivEthLinkParametersEntry 1 }
   phivEthDesigRouterNodeAddr OBJECT-TYPE
       SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value is the address of the designated router."
       ::= { phivEthLinkParametersEntry 2 }
   phivEthMaxRouters OBJECT-TYPE
       SYNTAX INTEGER (0..255)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This parameter is the maximum number of routers (other
            than the executor itself) allowed on the circuit by
            Routing for circuits that are owned by the executor
            node."
       ::= { phivEthLinkParametersEntry 3 }
   phivEthRouterPri OBJECT-TYPE
       SYNTAX INTEGER (0..127)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This parameter is the priority that this router is to
            have in the selection of designated router for the
            circuit on circuits that are owned by the executor
            node."
       DEFVAL { 64 }
       ::= { phivEthLinkParametersEntry 4 }
   phivEthHardwareAddr OBJECT-TYPE
       SYNTAX OCTET STRING ( SIZE (6) )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This read-only parameter is the address that is
           associated with the line device hardware as seen by
           the DECnet Software.  This value is not the same as
           ifPhysAddress."
       ::= { phivEthLinkParametersEntry 5 }
   -- Counters Group
   -- The implementation of the Counters Group is mandatory for
   -- systems which only support DECnet style locking counters.
   -- Counters Table
   phivCountersCountTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivCountersCountEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Information about ethernet link counters."
       ::= { counters 1 }
   phivCountersCountEntry OBJECT-TYPE
       SYNTAX PhivCountersCountEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Counter information about ethernet links currently
           known.."
       INDEX     { phivCountersIndex }
       ::= { phivCountersCountTable 1 }
   PhivCountersCountEntry ::=
       SEQUENCE {
           phivCountersIndex
               INTEGER,
           phivCountersCountBytesRecd
               PhivCounter,
           phivCountersCountBytesSent
               PhivCounter,
           phivCountersCountDataBlocksRecd
               PhivCounter,
           phivCountersCountDataBlocksSent
               PhivCounter,
           phivCountersCountEthUsrBuffUnav
               PhivCounter (0..65535),
           phivCountersCountMcastBytesRecd
               PhivCounter,
           phivCountersCountDataBlksRecd
               PhivCounter,
           phivCountersCountDataBlksSent
               PhivCounter,
           phivCountersCountMcastBlksRecd
               PhivCounter,
           phivCountersCountBlksSentDef
               PhivCounter,
           phivCountersCountBlksSentSingleCol
               PhivCounter,
           phivCountersCountBlksSentMultCol
               PhivCounter,
           phivCountersCountSendFailure
               PhivCounter,
           phivCountersCountCollDetectFailure
               PhivCounter (0..65535),
           phivCountersCountReceiveFailure
               PhivCounter (0..65535),
           phivCountersCountUnrecFrameDest
               PhivCounter (0..65535),
           phivCountersCountDataOver
               PhivCounter (0..65535),
           phivCountersCountSysBuffUnav
               PhivCounter (0..65535),
           phivCountersCountUsrBuffUnav
               PhivCounter (0..65535)
        }
   phivCountersIndex OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "The interface to which these counters apply.  This is
           the same interface as identified by the same value of
           phivLineIndex. This value is the IfIndex."
       ::= { phivCountersCountEntry 1 }
   phivCountersCountBytesRecd OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of bytes received over this link."
       ::= { phivCountersCountEntry 2 }
   phivCountersCountBytesSent OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of bytes sent over this link."
       ::= { phivCountersCountEntry 3 }
   phivCountersCountDataBlocksRecd OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of data blocks received over this link."
       ::= { phivCountersCountEntry 4 }
   phivCountersCountDataBlocksSent OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of data blocks sent over this link."
       ::= { phivCountersCountEntry 5 }
   phivCountersCountEthUsrBuffUnav OBJECT-TYPE
       SYNTAX PhivCounter (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of user buffer unavailable errors over this
           link."
       ::= { phivCountersCountEntry 6 }
   phivCountersCountMcastBytesRecd OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of multicast bytes received over this link."
       ::= { phivCountersCountEntry 7 }
   phivCountersCountDataBlksRecd OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of data blocks received over this link."
       ::= { phivCountersCountEntry 8 }
   phivCountersCountDataBlksSent OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of data blocks sent over this link."
       ::= { phivCountersCountEntry 9 }
   phivCountersCountMcastBlksRecd OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of multicast blocks received over this link."
       ::= { phivCountersCountEntry 10 }
   phivCountersCountBlksSentDef OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of blocks sent, initially deferred over this
           link."
       ::= { phivCountersCountEntry 11 }
   phivCountersCountBlksSentSingleCol OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of blocks sent, single collision over this link."
       ::= { phivCountersCountEntry 12 }
   phivCountersCountBlksSentMultCol OBJECT-TYPE
       SYNTAX PhivCounter
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of blocks sent, multiple collisions over this
           link."
       ::= { phivCountersCountEntry 13 }
   phivCountersCountSendFailure OBJECT-TYPE
       SYNTAX INTEGER ( 0..65535 )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of send failures over this link."
       ::= { phivCountersCountEntry 14 }
   phivCountersCountCollDetectFailure OBJECT-TYPE
       SYNTAX INTEGER ( 0..65535 )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of collision detect check failures over this
           link."
       ::= { phivCountersCountEntry 15 }
   phivCountersCountReceiveFailure OBJECT-TYPE
       SYNTAX INTEGER ( 0..65535 )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of receive failures over this link."
       ::= { phivCountersCountEntry 16 }
   phivCountersCountUnrecFrameDest OBJECT-TYPE
       SYNTAX INTEGER ( 0..65535 )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of unrecognized frame destinations over this
           link."
       ::= { phivCountersCountEntry 17 }
   phivCountersCountDataOver OBJECT-TYPE
       SYNTAX INTEGER ( 0..65535 )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of data overruns over this link."
       ::= { phivCountersCountEntry 18 }
   phivCountersCountSysBuffUnav OBJECT-TYPE
       SYNTAX INTEGER ( 0..65535 )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of system buffer unavailables over this link."
       ::= { phivCountersCountEntry 19 }
   phivCountersCountUsrBuffUnav OBJECT-TYPE
       SYNTAX INTEGER ( 0..65535 )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Number of user buffer unavailables."
       ::= { phivCountersCountEntry 20 }
   -- Adjacency Group
   -- The implementation of the Adjacency Group is mandatory for all
   -- conformant implementations of this memo.
   phivAdjTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivAdjEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "The Adjacency Table."
       ::= { adjacency 1 }
   phivAdjEntry OBJECT-TYPE
       SYNTAX PhivAdjEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "There is one entry in the table for each adjacency."
       INDEX  { phivAdjCircuitIndex }
       ::= { phivAdjTable 1 }
   PhivAdjEntry ::=
       SEQUENCE {
           phivAdjCircuitIndex
               INTEGER,
           phivAdjNodeAddr
               PhivAddr,
           phivAdjBlockSize
               INTEGER,
           phivAdjListenTimer
               INTEGER (1..65535),
           phivAdjCircuitEtherServPhysAddr
               OCTET STRING,
           phivAdjType
               INTEGER,
           phivAdjState
               INTEGER,
           phivAdjPriority
               INTEGER,
           phivAdjExecListenTimer
               INTEGER (1..65535)
        }
   phivAdjCircuitIndex OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "A unique index value for each known circuit."
       ::= { phivAdjEntry 1 }
   phivAdjNodeAddr OBJECT-TYPE
       SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "The address of the adjacent node."
       ::= { phivAdjEntry 2 }
   phivAdjBlockSize OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This read-only parameter is the block size that was
           negotiated with the adjacent Routing layer during Routing
           initialization over a particular circuit. It includes the
           routing header, but excludes the data link header. This
           parameter is qualified by ADJACENT NODE."
       ::= { phivAdjEntry 3 }
   phivAdjListenTimer OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value determines the maximum number of seconds
           allowed to elapse before Routing receives some message
           (either a Hello message or a user message) from the
           adjacent node on the circuit. It was agreed during
           Routing initialization with the adjacent Routing layer.
           This parameter is qualified by ADJACENT NODE."
       ::= { phivAdjEntry 4 }
   phivAdjCircuitEtherServPhysAddr OBJECT-TYPE
       SYNTAX OCTET STRING ( SIZE (6) )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This parameter indicates the Ethernet physical address
           of an adjacent node that is being serviced on this
           circuit. This parameter is a qualifier for SERVICE
           SUBSTATE."
       ::= { phivAdjEntry 5 }
   phivAdjType OBJECT-TYPE
       SYNTAX INTEGER {
           routing-III (1),
           nonrouting-III (2),
           area (3),
           routing-IV (4),
           nonrouting-IV (5)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This parameter indicates the type of adjacency.
           For adjacent nodes, this is a read-only parameter that
           indicates the type of the reachable adjacent node.
           NOTE: The routing-III and nonrouting-III values are
           incremented by one compared to the standard DECnet
           values in order to maintain compliance with RFC 1155)"
       ::= { phivAdjEntry 6 }
   phivAdjState OBJECT-TYPE
       SYNTAX INTEGER {
           initializing (1),          -- Ethernet one-way
           up (2),                    -- Ethernet two-way
           run (3),                   -- The eight DDCMP/X.25 states
           circuit-rejected (4),
           data-link-start (5),
           routing-layer-initialize (6),
           routing-layer-verify (7),
           routing-layer-complete (8),
           off (9),
           halt (10)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value indicates the state of a router adjacency.
           On adjacencies over a circuit of type
           (phivCircuitCommonType) Ethernet, CI, or FDDI, with an
           adjacent node of type (phivAdjType) ROUTING IV or AREA,
           this variable is the state of the Ethernet
           Initialization Layer for this adjacency, and can have
           values INITIALIZING or UP. (See Section 9.1.1 of
           DECnet Phase IV Routing Layer Functional Specification.)
           On adjacencies over a circuit of type
           (phivCircuitCommonType) Ethernet, CI, or FDDI, with an
           adjacent node of type (phivAdjType) NONROUTING IV,
           this variable will always take on the value UP.
           On adjacencies over a circuit of type
           (phivCircuitCommonType) DDCMP POINT, DDCMP CONTROL,
           DDCMP TRIBUTARY, DDCMP DMC, or X.25, this variable is
           the state of the Routing Layer Initialization Circuit
           State. (See section 7.3, ibid.)  It can have values
           between RUN and HALT.
           On adjacencies over a circuit of type
           (phivCircuitCommonType) OTHER, this variable may be
           used in a manner consistent with the Initialization
           Layer used on that circuit."
       ::= { phivAdjEntry 7 }
   phivAdjPriority OBJECT-TYPE
       SYNTAX INTEGER (0..255)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "Priority assigned by the adjacent node for this
           circuit."
    ::= { phivAdjEntry 8 }
   phivAdjExecListenTimer OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This read-only value determines the maximum number of
           seconds allowed to elapse before Routing receives some
           message (either a Hello message or a user message) from
           the adjacent node on the circuit. It was agreed during
           Routing initialization with the adjacent Routing layer."
       ::= { phivAdjEntry 9 }
   -- Line Group
   -- The implementation of the Line Group is mandatory for all
   -- conformant implementations of this memo.
   phivLineTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivLineEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "The Line Table."
       ::= { line 1 }
   phivLineEntry OBJECT-TYPE
       SYNTAX PhivLineEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "There is one entry in the table for each line."
       INDEX  { phivLineIndex }
       ::= { phivLineTable 1 }
   PhivLineEntry ::=
       SEQUENCE {
           phivLineIndex
               INTEGER,
           phivLineName
               DisplayString,
           phivLineState
               INTEGER,
           phivLineSubstate
               INTEGER,
           phivLineService
               INTEGER,
           phivLineDevice
               DisplayString,
           phivLineReceiveBuffs
               INTEGER (0..65535),
           phivLineProtocol
               INTEGER,
           phivLineServiceTimer
               INTEGER (1..65535),
           phivLineMaxBlock
               INTEGER (1..65535)
       }
   phivLineIndex OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "The line on which this entry's equivalence is effective.
           This is the same as the IfIndex."
       ::= { phivLineEntry 1 }
   phivLineName OBJECT-TYPE
       SYNTAX DisplayString ( SIZE (0..16) )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "The name of the line on this row of the table."
       ::= { phivLineEntry 2 }
   phivLineState OBJECT-TYPE
       SYNTAX INTEGER {
                on (1),
                off (2),
                service (3),
                cleared (4)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents Network Management operational
           state.
           NOTE that these values are incremented by one compared to
           the standard DECnet values."
       ::= { phivLineEntry 3 }
   phivLineSubstate OBJECT-TYPE
       SYNTAX INTEGER {
               starting (1),
               reflecting (2),
               looping (3),
               loading (4),
               dumping (5),
               triggering (6),
               auto-service (7),
               auto-loading (8),
               auto-dumping (9),
               auto-triggering (10),
               synchronizing (11),
               failed (12),
               running (13)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the line's read-only Network
           Management substate.
           NOTE that these values are incremented by one compared to
           the standard DECnet values."
       ::= { phivLineEntry 4 }
   phivLineService OBJECT-TYPE
       SYNTAX INTEGER {
             starting (1),
             reflecting (2),
             looping (3),
             other (4)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the line's read-only Network
           Management service.
           NOTE that these values are incremented by one compared to
           the standard DECnet values and OTHER is a new addition."
       ::= { phivLineEntry 5 }
   phivLineDevice OBJECT-TYPE
       SYNTAX DisplayString ( SIZE (0..16) )
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the Physical Link device to be
           used on the line."
       ::= { phivLineEntry 6 }
   phivLineReceiveBuffs OBJECT-TYPE
       SYNTAX INTEGER (0..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the number of receive buffers
           reserved for the line. It is a decimal number in
           the range 0-65535.  0 is supported for those vendors
           that do not reserve buffers on a per line basis and
           use a pool of buffers that can be used by any line."
       ::= { phivLineEntry 7 }
   phivLineProtocol OBJECT-TYPE
       SYNTAX INTEGER {
           ddcmp-point (1),
           ddcmp-control (2),
           ddcmp-tributary (3),
           reserved (4),
           ddcmp-dmc (5),
           lapb (6),
           ethernet (7),
           ci (8),
           qp2 (9),
           other (14),
           fddi (15)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the protocol used on the line
           device.  Note that these values are incremented by
           one compared to the standard DECnet values."
       ::= { phivLineEntry 8 }
   phivLineServiceTimer OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the amount of time in
           milliseconds allowed to elapse before a Data Link
           receive request completes while doing service
           operations."
       ::= { phivLineEntry 9 }
   phivLineMaxBlock OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the Data Link maximum block
           size on the line."
       ::= { phivLineEntry 10 }
   -- Non Broadcast Line Group
   -- The implementation of the Non Broadcast Line Group is
   -- mandatory for all systems which implement non broadcast
   -- lines.
   phivNonBroadcastTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivNonBroadcastEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "The Non Broadcast Table."
       ::= { nonBroadcastLine 1 }
   phivNonBroadcastEntry OBJECT-TYPE
       SYNTAX PhivNonBroadcastEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "There is one entry in the table for each
           Non Broadcast line."
       INDEX  { phivNonBroadcastIndex }
       ::= { phivNonBroadcastTable 1 }
   PhivNonBroadcastEntry ::=
       SEQUENCE {
           phivNonBroadcastIndex
               INTEGER,
           phivNonBroadcastController
               INTEGER,
           phivNonBroadcastDuplex
               INTEGER,
           phivNonBroadcastClock
               INTEGER,
           phivNonBroadcastRetransmitTimer
               INTEGER (1..65535)
       }
   phivNonBroadcastIndex OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "The Non Broadcast line on which this entry's
           equivalence is effective.  This is the same value
           as the IfIndex."
       ::= { phivNonBroadcastEntry 1 }
   phivNonBroadcastController OBJECT-TYPE
       SYNTAX INTEGER {
             normal (1),
             loopback (2),
             other (3)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the Physical Link hardware
           controller mode for the line device. The values
           for controller-mode are:
           NORMAL  For normal controller operating mode.
           LOOPBACK For software controllable loopback of the
           controller. On those devices that can support this
           mode, it causes all transmitted messages to be looped
           back from within the controller itself. This is
           accomplished without any manual intervention other
           than the setting of this parameter value.
    OTHER indicates function is not supported
           Note that these values are incremented by one compared to
           the standard DECnet values."
       ::= { phivNonBroadcastEntry 2 }
   phivNonBroadcastDuplex OBJECT-TYPE
       SYNTAX INTEGER {
             full (1),
             half (2)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the Physical Link hardware
           duplex mode of the line device. The possible modes
           are:
           FULL   Full-duplex
           HALF   Half-duplex
           Note that these values are incremented by one compared to
           the standard DECnet values."
       ::= { phivNonBroadcastEntry 3 }
   phivNonBroadcastClock OBJECT-TYPE
       SYNTAX INTEGER {
              external (1),
              internal (2),
              other (3)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents the Physical Link hardware clock
           mode for the line device. The values for clock-mode are:
           INTERNAL For software controllable loopback use of
           the clock. On those devices that can support this
           mode, it causes the device to supply a clock signal
           such that a transmitted messages can be looped
           back from outside the device. This may require manual
           intervention other than the setting of this parameter
           value. For example, the operator may have to connect
           a loopback plug in place of the normal line.
           EXTERNAL For normal clock operating mode, where the
           clock signal is supplied externally to the controller.
           Note that these values are incremented by one compared to
           the standard DECnet values."
       ::= { phivNonBroadcastEntry 4 }
   phivNonBroadcastRetransmitTimer OBJECT-TYPE
       SYNTAX INTEGER (1..65535)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value represents number of milliseconds before
           the Data Link retransmits a block on the line. On
           half-duplex lines, this parameter is the select timer."
       DEFVAL { 3000 }
       ::= { phivNonBroadcastEntry 5 }
   -- Area Parameters Group
   -- The implementation of the Area Parameters Group is mandatory
   -- for all systems which implement level 2 routing.
   phivAreaTable OBJECT-TYPE
       SYNTAX SEQUENCE OF PhivAreaEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "Table of information kept on all areas known to
           this unit."
       ::= { area 1 }
   phivAreaEntry OBJECT-TYPE
       SYNTAX PhivAreaEntry
       ACCESS not-accessible
       STATUS mandatory
       DESCRIPTION
           "The area routing information."
       INDEX  { phivAreaNum }
       ::= { phivAreaTable 1 }
   PhivAreaEntry ::=
       SEQUENCE {
           phivAreaNum
             INTEGER,
           phivAreaState
             INTEGER,
           phivAreaCost
             Gauge,
           phivAreaHops
             INTEGER,
           phivAreaNextNode
             PhivAddr,
           phivAreaCircuitIndex
             INTEGER
       }
   phivAreaNum OBJECT-TYPE
       SYNTAX INTEGER (0..64)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value indicates the area number of this entry."
       ::= { phivAreaEntry 1 }
   phivAreaState OBJECT-TYPE
       SYNTAX INTEGER {
          reachable (4),
          unreachable (5)
       }
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "This value indicates the state of the area"
       ::= { phivAreaEntry 2 }
   phivAreaCost OBJECT-TYPE
       SYNTAX Gauge
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "The total cost over the current path to the
            destination area. Cost is a value associated with
            using a circuit. Routing routes messages (data)
            along the path between 2 areas with the smallest
            cost."
       ::= { phivAreaEntry 3 }
   phivAreaHops OBJECT-TYPE
       SYNTAX INTEGER (0..255)
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "The number of hops to a destination area. A hop is
           the routing value representing the logical distance
           between two areas in network."
       ::= { phivAreaEntry 4 }
   phivAreaNextNode OBJECT-TYPE
       SYNTAX PhivAddr
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "The next node on the circuit used to get to the
           area under scrutiny."
       ::= { phivAreaEntry 5 }
   phivAreaCircuitIndex OBJECT-TYPE
       SYNTAX INTEGER
       ACCESS read-only
       STATUS mandatory
       DESCRIPTION
           "A unique index value for each known circuit."
       ::= { phivAreaEntry 6 }
   -- Additional Area Parameters
   phivAreaMaxCost OBJECT-TYPE
       SYNTAX INTEGER (1..1022)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum total path cost
           allowed from the executor to any other level 2 routing
           node. The AREA MAXIMUM COST number is decimal in the
           range 1-1022. This parameter is only applicable if
           the executor node is of type AREA."
       ::= { area 2 }
   phivAreaMaxHops OBJECT-TYPE
       SYNTAX INTEGER (1..30)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the maximum number of routing hops
           allowable from the executor to any other level 2
           routing node.  This parameter is only applicable if the
           executor node is of type AREA."
       ::= { area 3 }
   phivRouteMaxArea OBJECT-TYPE
       SYNTAX INTEGER (1..63)
       ACCESS read-write
       STATUS mandatory
       DESCRIPTION
           "This value represents the largest area number and,
           therefore, number of areas that can be known about
           by the executor node's Routing. This parameter is only
           applicable if the executor node is of type AREA."
       ::= { area 4 }
   END

Acknowledgements

This document is the result of work undertaken the by DECnet Phase IV MIB working group. In addition, the special contributions and comments of the following members are also acknowledged:

 Chris Chiotasso, Sparticus
 Steven Hunter, National Energy Research Supercomputer Center,
 Lawrence Livermore National Laboratory

References

Cerf, V., "IAB Recommendations for the Development of Internet Network Management Standards", RFC 1052, NRI, April 1988.

Rose M., and K. McCloghrie, "Structure and Identification of Management Information for TCP/IP-based internets", RFC 1155, Performance Systems International, Hughes LAN Systems, May 1990.

McCloghrie K., and M. Rose, "Management Information Base for Network Management of TCP/IP-based internets", RFC 1156, Hughes LAN Systems, Performance Systems International, May 1990.

Case, J., Fedor, M., Schoffstall, M., and J. Davin, "Simple Network Management Protocol", RFC 1157, SNMP Research, Performance Systems International, Performance Systems International, MIT Laboratory for Computer Science, May 1990.

McCloghrie K., and M. Rose, Editors, "Management Information Base for Network Management of TCP/IP-based internets", RFC 1213, Performance Systems International, March 1991.

Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions", RFC 1212, Performance Systems International, Hughes LAN Systems, March 1991.

Cook, J., Editor, "Definitions of Managed Objects for the Ethernet- like Interface Types", RFC 1284, Chipcom Corporation, December 1991.

Digital Equipment Corporation, "DECnet-ULTRIX NCP Command Reference", Digital Equipment Corporation, Maynard, Massachusetts.

Digital Equipment Corporation, "DECnet-ULTRIX USE Guide", Digital Equipment Corporation, Maynard, Massachusetts.

Digital Equipment Corporation, "DECnet DIGITAL Network Architecture, Network Management Functional Specification", Version 4.0.0. Digital Equipment Corporation, Maynard, Massachusetts, July 1983.

Digital Equipment Corporation, "DECnet DIGITAL Network Architecture, Routing Layer Functional Specification", Version 2.0.0. Digital Equipment Corporation, Maynard, Massachusetts, May 1983.

Security Considerations

Security issues are not discussed in this memo.

Author's Address

Jon Saperia Digital Equipment Corporation 40 Old Bolton Road Stow, Massachusetts 01775-1215

Phone: 508-496-8333

EMail: [email protected]