Status of this Memo

This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited.

Copyright Notice

Copyright (C) The Internet Society (1997). All Rights Reserved.

Abstract

This document describes the Message Processing and Dispatching for SNMP messages within the SNMP architecture RFC2261. It defines the procedures for dispatching potentially multiple versions of SNMP messages to the proper SNMP Message Processing Models, and for dispatching PDUs to SNMP applications. This document also describes one Message Processing Model - the SNMPv3 Message Processing Model.

5.1. Definitions for SNMP Message Processing and Dispatching .. 15

Introduction

The Architecture for describing Internet Management Frameworks RFC2261 describes that an SNMP engine is composed of:

    1) a Dispatcher
    2) a Message Processing Subsystem,
    3) a Security Subsystem, and
    4) an Access Control Subsystem.

Applications make use of the services of these subsystems.

It is important to understand the SNMP architecture and its terminology to understand where the Message Processing Subsystem and Dispatcher described in this document fit into the architecture and

interact with other subsystems within the architecture. The reader is expected to have read and understood the description of the SNMP architecture, defined in RFC2261.

The Dispatcher in the SNMP engine sends and receives SNMP messages. It also dispatches SNMP PDUs to SNMP applications. When an SNMP message needs to be prepared or when data needs to be extracted from an SNMP message, the Dispatcher delegates these tasks to a message version-specific Message Processing Model within the Message Processing Subsystem.

A Message Processing Model is responsibile for processing a SNMP version-specific message and for coordinating the interaction with the Security Subsystem to ensure proper security is applied to the SNMP message being handled.

Interactions between the Dispatcher, the Message Processing Subsystem, and applications are modelled using abstract data elements and abstract service interface primitives defined by the SNMP architecture.

Similarly, interactions between the Message Processing Subsystem and the Security Subsystem are modelled using abstract data elements and abstract service interface primitives as defined by the SNMP architecture.

The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in RFC 2119.

Overview

The following illustration depicts the Message Processing in relation to SNMP applications, the Security Subsystem and Transport Mappings.

+-------------------------------------------------------------------+ | SNMP Entity | | | | +---------------------------------------------------------------+ | | | Applications | | | | +-----------+ +--------------+ | | | | | Command | | Notification | | | | | | Generator | | Originator | +-----------+ +--------------+| | | | +-----------+ +--------------+ | Proxy | | Other | | | | +-----------+ +--------------+ | Forwarder | |Application(s)|| | | | | Command | | Notification | +-----------+ +--------------+| | | | | Responder | | Receiver | | | | | +-----------+ +--------------+ | | | +---------------------------------------------------------------+ | | ^ ^ ^ ^ | | | | | | | | v v v v | | +--------+-------+---------------+-----------+ | | ^ | | | +---------------------+ +-----------------+ | | | | Message Processing | | Security | | | Dispatcher v | Subsystem | | Subsystem | | | +------------------+ | +------------+ | | | | | | PDU Dispatcher | | +->| v1MP * |<--->| +-------------+ | | | | | | | +------------+ | | | Other | | | | | | | | +------------+ | | | Security | | | | | | | +->| v2cMP * |<--->| | Model | | | | | Message | | | +------------+ | | +-------------+ | | | | Dispatcher <-------->+ | | | | | | | | | +------------+ | | +-------------+ | | | | | | +->| v3MP * |<--->| | User-based | | | | | Transport | | | +------------+ | | | Security | | | | | Mapping | | | +------------+ | | | Model | | | | | (e.g RFC1906) | | +->| otherMP * |<--->| +-------------+ | | | +------------------+ | +------------+ | | | | | ^ +---------------------+ +-----------------+ | | | | +----------|--------------------------------------------------------+

          v
 +------------------+
 |   Network        |
 +------------------+

The Dispatcher.

The Dispatcher is a key piece of an SNMP engine. There is only one in an SNMP engine, and its job is to dispatch tasks to the multiple version-specific Message Processing Models, and to dispatch PDUs to various applications.

For outgoing messages, an application provides a PDU to be sent, plus the data needed to prepare and send the message, and the application specifies which version-specific Message Processing Model will be used to prepare the message with the desired security processing. Once the message is prepared, the Dispatcher sends the message.

For incoming messages, the Dispatcher determines the SNMP version of the incoming message and passes the message to the version-specific Message Processing Model to extract the components of the message and to coordinate the processing of security services for the message. After version-specific processing, the PDU Dispatcher determines which application, if any, should receive the PDU for processing and forwards it accordingly.

The Dispatcher, while sending and receiving SNMP messages, collects statistics about SNMP messages and the behavior of the SNMP engine in managed objects to make them accessible to remote SNMP entities. This document defines these managed objects, the MIB module which contains them, and how these managed objects might be used to provide useful management.

Message Processing Subsystem

The SNMP Message Processing Subsystem is the part of an SNMP engine which interacts with the Dispatcher to handle the version-specific SNMP messages. It contains one or more Message Processing Models.

This document describes one Message Processing Model, the SNMPv3 Message Processing Model, in Section 6. The SNMPv3 Message Processing Model is defined in a separate section to show that multiple (independent) Message Processing Models can exist at the same time and that such Models can be described in different documents. The SNMPv3 Message Processing Model can be replaced or supplemented with other Message Processing Models in the future. Two Message Processing Models which are expected to be developed in the future are the SNMPv1 message format RFC1157 and the SNMPv2c message format RFC1901. Others may be developed as needed.

Elements of Message Processing and Dispatching

See RFC2261 for the definitions of

       contextEngineID
       contextName
       scopedPDU
       maxSizeResponseScopedPDU
       securityModel
       securityName
       securityLevel
       messageProcessingModel

For incoming messages, a version-specific message processing module provides these values to the Dispatcher. For outgoing messages, an application provides these values to the Dispatcher.

For some version-specific processing, the values may be extracted from received messages; for other versions, the values may be determined by algorithm, or by an implementation-defined mechanism. The mechanism by which the value is determined is irrelevant to the Dispatcher.

The following additional or expanded definitions are for use within the Dispatcher.

messageProcessingModel

The value of messageProcessingModel identifies a Message Processing Model. A Message Processing Model describes the version-specific procedures for extracting data from messages, generating messages, calling upon a securityModel to apply its security services to messages, for converting data from a version-specific message format into a generic format usable by the Dispatcher, and for converting data from Dispatcher format into a version-specific message format.

pduVersion

The value of pduVersion represents a specific version of protocol operation and its associated PDU formats, such as SNMPv1 or SNMPv2 RFC1905. The values of pduVersion are specific to the version of the PDU contained in a message, and the PDUs processed by applications. The Dispatcher does not use the value of pduVersion directly.

An application specifies the pduVersion when it requests the PDU Dispatcher to send a PDU to another SNMP engine. The Dispatcher passes the pduVersion to a Message Processing Model, so it knows how to handle the PDU properly.

For incoming messages, pduVersion is provided to the Dispatcher by a version-specific Message Processing module. The PDU Dispatcher passes the pduVersion to the application so it knows how to handle the PDU properly. For example, a command responder application needs to know whether to use RFC1905 elements of procedure and syntax instead of those specified for SNMPv1.

pduType

A value of pduType represents a specific type of protocol operation. The values of pduType are specific to the version of the PDU contained in a message.

Applications register to support particular pduTypes for particular contextEngineIDs.

For incoming messages, pduType is provided to the Dispatcher by a version-specific Message Processing module. It is subsequently used to dispatch the PDU to the application which registered for the pduType for the contextEngineID of the associated scopedPDU.

sendPduHandle

This handle is generated for coordinating the processing of requests and responses between the SNMP engine and an application. The handle must be unique across all version-specific Message Processing Models, and is of local significance only.

Dispatcher Elements of Procedure

This section describes the procedures followed by the Dispatcher when generating and processing SNMP messages.

Sending an SNMP Message to the Network

This section describes the procedure followed by an SNMP engine whenever it sends an SNMP message.

Sending a Request or Notification

The following procedures are followed by the Dispatcher when an application wants to send an SNMP PDU to another (remote) application, i.e., to initiate a communication by originating a message, such as one containing a request or a trap.

1) The application requests this using the abstract service

  primitive:
   statusInformation =              -- sendPduHandle if success
                                    -- errorIndication if failure
     sendPdu(
     IN   transportDomain           -- transport domain to be used
     IN   transportAddress          -- destination network address
     IN   messageProcessingModel    -- typically, SNMP version
     IN   securityModel             -- Security Model to use
     IN   securityName              -- on behalf of this principal
     IN   securityLevel             -- Level of Security requested
     IN   contextEngineID           -- data from/at this entity
     IN   contextName               -- data from/in this context
     IN   pduVersion                -- the version of the PDU
     IN   PDU                       -- SNMP Protocol Data Unit
     IN   expectResponse            -- TRUE or FALSE
          )

2) If the messageProcessingModel value does not represent a Message

  Processing Model known to the Dispatcher, then an errorIndication
  (implementation-dependent) is returned to the calling application.
  No further processing is performed.

3) The Dispatcher generates a sendPduHandle to coordinate

  subsequent processing.

4) The Message Dispatcher sends the request to the version-specific

  Message Processing module identified by messageProcessingModel
  using the abstract service primitive:
  statusInformation =              - success or error indication
    prepareOutgoingMessage(
    IN   transportDomain           -- as specified by application
    IN   transportAddress          -- as specified by application
    IN   messageProcessingModel    -- as specified by application
    IN   securityModel             -- as specified by application
    IN   securityName              -- as specified by application
    IN   securityLevel             -- as specified by application
    IN   contextEngineID           -- as specified by application
    IN   contextName               -- as specified by application
    IN   pduVersion                -- the version of the PDU
    IN   PDU                       -- as specified by application
    IN   expectResponse            -- as specified by application
    IN   sendPduHandle             -- as determined in step 3.
    OUT  destTransportDomain       -- destination transport domain
    OUT  destTransportAddress      -- destination transport address
    OUT  outgoingMessage           -- the message to send
    OUT  outgoingMessageLength     -- the message length
         )

5) If the statusInformation indicates an error, the errorIndication

  is returned to the calling application.  No further processing is
  performed.

6) If the statusInformation indicates success, the sendPduHandle is

  returned to the application, and the outgoingMessage is sent via
  the transport specified by the transportDomain to the address
  specified by the transportAddress.

Outgoing Message Processing is complete.

Sending a Response to the Network

The following procedure is followed when an application wants to return a response back to the originator of an SNMP Request.

1) An application can request this using the abstract service

  primitive:
  returnResponsePDU(
   IN   messageProcessingModel   -- typically, SNMP version
   IN   securityModel            -- Security Model in use
   IN   securityName             -- on behalf of this principal
   IN   securityLevel            -- same as on incoming request
   IN   contextEngineID          -- data from/at this SNMP entity
   IN   contextName              -- data from/in this context
   IN   pduVersion               -- the version of the PDU
   IN   PDU                      -- SNMP Protocol Data Unit
   IN   maxSizeResponseScopedPDU -- maximum size of Response PDU
   IN   stateReference           -- reference to state information
                                 -- as presented with the request
   IN   statusInformation        -- success or errorIndication
   )                             -- (error counter OID and value
                                 -- when errorIndication)

2) The Message Dispatcher sends the request to the appropriate

  Message Processing Model indicated by the received value of
  messageProcessingModel using the abstract service primitive:
  result =                        -- SUCCESS or errorIndication
   prepareResponseMessage(
   IN   messageProcessingModel   -- specified by application
   IN   securityModel            -- specified by application
   IN   securityName             -- specified by application
   IN   securityLevel            -- specified by application
   IN   contextEngineID          -- specified by application
   IN   contextName              -- specified by application
   IN   pduVersion               -- specified by application
   IN   PDU                      -- specified by application
   IN   maxSizeResponseScopedPDU -- specified by application
   IN   stateReference           -- specified by application
   IN   statusInformation        -- specified by application
   OUT  destTransportDomain      -- destination transport domain
   OUT  destTransportAddress     -- destination transport address
   OUT  outgoingMessage          -- the message to send
   OUT  outgoingMessageLength    -- the message length
        )

3) If the result is an errorIndication, the errorIndication is

  returned to the calling application.  No further processing is
  performed.

4) If the result is success, the outgoingMessage is sent over the

  transport specified by the transportDomain to the address
  specified by the transportAddress.

Message Processing is complete.

Receiving an SNMP Message from the Network

This section describes the procedure followed by an SNMP engine whenever it receives an SNMP message.

Please note, that for the sake of clarity and to prevent the text from being even longer and more complicated, some details were omitted from the steps below. In particular, The elements of procedure do not always explicitly indicate when state information needs to be released. The general rule is that if state information is available when a message is to be "discarded without further processing", then the state information must also be released at that same time.

Message Dispatching of received SNMP Messages

1) The snmpInPkts counter RFC1907 is incremented.

2) The version of the SNMP message is determined in an

  implementation-dependent manner.  If the packet cannot be
  sufficiently parsed to determine the version of the SNMP message,
  then the snmpInASNParseErrs RFC1907 counter is incremented, and
  the message is discarded without further processing.  If the
  version is not supported, then the snmpInBadVersions RFC1907
  counter is incremented, and the message is discarded without
  further processing.

3) The origin transportDomain and origin transportAddress are

  determined.

4) The message is passed to the version-specific Message Processing

  Model which returns the abstract data elements required by the
  Dispatcher.  This is performed using the abstract service
  primitive:
  result =                        -- SUCCESS or errorIndication
    prepareDataElements(
    IN   transportDomain          -- origin as determined in step 3.
    IN   transportAddress         -- origin as determined in step 3.
    IN   wholeMsg                 -- as received from the network
    IN   wholeMsgLength           -- as received from the network
    OUT  messageProcessingModel   -- typically, SNMP version
    OUT  securityModel            -- Security Model to use
    OUT  securityName             -- on behalf of this principal
    OUT  securityLevel            -- Level of Security requested
    OUT  contextEngineID          -- data from/at this entity
    OUT  contextName              -- data from/in this context
    OUT  pduVersion               -- the version of the PDU
    OUT  PDU                      -- SNMP Protocol Data Unit
    OUT  pduType                  -- SNMP PDU type
    OUT  sendPduHandle            -- handle for a matched request
    OUT  maxSizeResponseScopedPDU -- maximum size of Response PDU
    OUT  statusInformation        -- success or errorIndication
                                  -- (error counter OID and value
                                  -- when errorIndication)
    OUT  stateReference           -- reference to state information
                                  -- to be used for a possible
         )                        -- Response

5) If the result is a FAILURE errorIndication, the message is

  discarded without further processing.

6) At this point, the abstract data elements have been prepared and

  processing continues as described in Section 4.2.2, PDU
  Dispatching for Incoming Messages.

PDU Dispatching for Incoming Messages

The elements of procedure for the dispatching of PDUs depends on the value of sendPduHandle. If the value of sendPduHandle is <none>, then this is a request or notification and the procedures specified in Section 4.2.2.1 apply. If the value of snmpPduHandle is not <none>, then this is a response and the procedures specified in Section 4.2.2.2 apply.

Incoming Requests and Notifications

The following procedures are followed for the dispatching of PDUs when the value of sendPduHandle is <none>, indicating this is a request or notification.

1) The combination of contextEngineID and pduType is used to

  determine which application has registered for this request or
  notification.

2) If no application has registered for the combination, then

  a) The snmpUnknownPDUHandlers counter is incremented.
  b) A Response message is generated using the abstract service
     primitive:
     result =                         -- SUCCESS or FAILURE
     prepareResponseMessage(
     IN   messageProcessingModel    -- as provided by MP module
     IN   securityModel             -- as provided by MP module
     IN   securityName              -- as provided by MP module
     IN   securityLevel             -- as provided by MP module
     IN   contextEngineID           -- as provided by MP module
     IN   contextName               -- as provided by MP module
     IN   pduVersion                -- as provided by MP module
     IN   PDU                       -- as provided by MP module
     IN   maxSizeResponseScopedPDU  -- as provided by MP module
     IN   stateReference            -- as provided by MP module
     IN   statusInformation         -- errorIndication plus
                                    -- snmpUnknownPDUHandlers OID
                                    -- value pair.
     OUT  transportDomain           -- destination transportDomain
     OUT  transportAddress          -- destination transportAddress
     OUT  outgoingMessage           -- the message to send
     OUT  outgoingMessageLength     -- its length
     )
  c) If the result is SUCCESS, then the prepared message is sent to
     the originator of the request as identified by the
     transportDomain and transportAddress.
  d) The incoming message is discarded without further processing.
     Message Processing for this message is complete.

3) The PDU is dispatched to the application, using the abstract

  service primitive:
  processPdu(                     -- process Request/Notification
    IN   messageProcessingModel   -- as provided by MP module
    IN   securityModel            -- as provided by MP module
    IN   securityName             -- as provided by MP module
    IN   securityLevel            -- as provided by MP module
    IN   contextEngineID          -- as provided by MP module
    IN   contextName              -- as provided by MP module
    IN   pduVersion               -- as provided by MP module
    IN   PDU                      -- as provided by MP module
    IN   maxSizeResponseScopedPDU -- as provided by MP module
    IN   stateReference           -- as provided by MP module
                                  -- needed when sending response
         )
  Message processing for this message is complete.
Incoming Responses

The following procedures are followed for the dispatching of PDUs when the value of sendPduHandle is not <none>, indicating this is a response.

  1) The value of sendPduHandle is used to determine, in an
     implementation-defined manner, which application is waiting for
     a response PDU associated with this sendPduHandle.
  2) If no waiting application is found, the message is discarded
     without further processing, and the stateReference is released.
     The snmpUnknownPDUHandlers counter is incremented.  Message
     Processing is complete for this message.
  3) Any cached information, including stateReference, about the
     message is discarded.
  4) The response is dispatched to the application using the
     abstract service primitive:
     processResponsePdu(              -- process Response PDU
       IN   messageProcessingModel    -- provided by the MP module
       IN   securityModel             -- provided by the MP module
       IN   securityName              -- provided by the MP module
       IN   securityLevel             -- provided by the MP module
       IN   contextEngineID           -- provided by the MP module
       IN   contextName               -- provided by the MP module
       IN   pduVersion                -- provided by the MP module
       IN   PDU                       -- provided by the MP module
       IN   statusInformation         -- provided by the MP module
       IN   sendPduHandle             -- provided by the MP module
            )
     Message Processing is complete for this message.

Application Registration for Handling PDU types

Applications that want to process certain PDUs must register with the PDU Dispatcher. Applications specify the combination of contextEngineID and pduType(s) for which they want to take responsibility

1) An application registers according to the abstract interface

  primitive:
  statusInformation =           -- success or errorIndication
    registerContextEngineID(
    IN   contextEngineID        -- take responsibility for this one
    IN   pduType                -- the pduType(s) to be registered
         )
  Note: implementations may provide a means of requesting
  registration for simultaneous multiple contextEngineID values,
  e.g., all contextEngineID values, and may also provide means for
  requesting simultaneous registration for multiple values of
  pduType.

2) The parameters may be checked for validity; if they are not, then

  an errorIndication (invalidParameter) is returned to the
  application.

3) Each combination of contextEngineID and pduType can be registered

  only once.  If another application has already registered for the
  specified combination, then an errorIndication (alreadyRegistered)
  is returned to the application.

4) Otherwise, the registration is saved so that SNMP PDUs can be

  dispatched to this application.

Application Unregistration for Handling PDU Types

Applications that no longer want to process certain PDUs must unregister with the PDU Dispatcher.

1) An application unregisters using the abstract service primitive:

  unregisterContextEngineID(
   IN   contextEngineID        -- give up responsibility for this
   IN   pduType                -- the pduType(s) to be unregistered
         )
  Note: implementations may provide means for requesting
  unregistration for simultaneous multiple contextEngineID values,
  e.g., all contextEngineID values, and may also provide means for
  requesting simultaneous unregistration for multiple values of
  pduType.

2) If the contextEngineID and pduType combination has been

  registered, then the registration is deleted.
  If no such registration exists, then the request is ignored.

Definitions

Definitions for SNMP Message Processing and Dispatching

SNMP-MPD-MIB DEFINITIONS ::= BEGIN

IMPORTS

   MODULE-COMPLIANCE, OBJECT-GROUP         FROM SNMPv2-CONF
   MODULE-IDENTITY, OBJECT-TYPE,
   snmpModules, Counter32                  FROM SNMPv2-SMI;

snmpMPDMIB MODULE-IDENTITY

   LAST-UPDATED "9711200000Z"              -- 20 November 1997
   ORGANIZATION "SNMPv3 Working Group"
   CONTACT-INFO "WG-email:   [email protected]
                 Subscribe:  [email protected]
                             In message body:  subscribe snmpv3
                 Chair:      Russ Mundy
                             Trusted Information Systems
                 postal:     3060 Washington Road
                             Glenwood, MD 21738
                             USA
                 email:      [email protected]
                 phone:      +1 301-854-6889
                 Co-editor:  Jeffrey Case
                             SNMP Research, Inc.
                 postal:     3001 Kimberlin Heights Road
                             Knoxville, TN 37920-9716
                             USA
                 email:      [email protected]
                 phone:      +1 423-573-1434
                 Co-editor   Dave Harrington
                             Cabletron Systems, Inc.
                 postal:     Post Office Box 5005
                             MailStop: Durham
                             35 Industrial Way
                             Rochester, NH 03867-5005
                             USA
                 email:      [email protected]
                 phone:      +1 603-337-7357
                 Co-editor:  Randy Presuhn
                             BMC Software, Inc.
                 postal:     1190 Saratoga Ave, Suite 190
                             San Jose, CA 95120
                             USA
                 email:      [email protected]
                 phone:      +1 408-556-0720
                 Co-editor:  Bert Wijnen
                             IBM T. J. Watson Research
                 postal:     Schagen 33
                             3461 GL Linschoten
                             Netherlands
                 email:      [email protected]
                 phone:      +31 348-432-794
                "
   DESCRIPTION  "The MIB for Message Processing and Dispatching"
   ::= { snmpModules 3 }

-- Administrative assignments ***************************************

snmpMPDAdmin OBJECT IDENTIFIER ::= { snmpMPDMIB 1 } snmpMPDMIBObjects OBJECT IDENTIFIER ::= { snmpMPDMIB 2 } snmpMPDMIBConformance OBJECT IDENTIFIER ::= { snmpMPDMIB 3 }

-- Statistics for SNMP Messages *************************************

snmpMPDStats OBJECT IDENTIFIER ::= { snmpMPDMIBObjects 1 }

snmpUnknownSecurityModels OBJECT-TYPE

   SYNTAX       Counter32
   MAX-ACCESS   read-only
   STATUS       current
   DESCRIPTION "The total number of packets received by the SNMP
                engine which were dropped because they referenced a
                securityModel that was not known to or supported by
                the SNMP engine.
               "
   ::= { snmpMPDStats 1 }

snmpInvalidMsgs OBJECT-TYPE

   SYNTAX       Counter32
   MAX-ACCESS   read-only
   STATUS       current
   DESCRIPTION "The total number of packets received by the SNMP
                engine which were dropped because there were invalid
                or inconsistent components in the SNMP message.
               "
   ::= { snmpMPDStats 2 }

snmpUnknownPDUHandlers OBJECT-TYPE

   SYNTAX       Counter32
   MAX-ACCESS   read-only
   STATUS       current
   DESCRIPTION "The total number of packets received by the SNMP
                engine which were dropped because the PDU contained
                in the packet could not be passed to an application
                responsible for handling the pduType, e.g. no SNMP
                application had registered for the proper
                combination of the contextEngineID and the pduType.
               "
   ::= { snmpMPDStats 3 }

-- Conformance information ******************************************

snmpMPDMIBCompliances OBJECT IDENTIFIER ::= {snmpMPDMIBConformance 1} snmpMPDMIBGroups OBJECT IDENTIFIER ::= {snmpMPDMIBConformance 2}

-- Compliance statements

snmpMPDCompliance MODULE-COMPLIANCE

   STATUS       current
   DESCRIPTION "The compliance statement for SNMP entities which
                implement the SNMP-MPD-MIB.
               "
   MODULE    -- this module
       MANDATORY-GROUPS { snmpMPDGroup }
   ::= { snmpMPDMIBCompliances 1 }

snmpMPDGroup OBJECT-GROUP

   OBJECTS {
             snmpUnknownSecurityModels,
             snmpInvalidMsgs,
             snmpUnknownPDUHandlers
           }
   STATUS       current
   DESCRIPTION "A collection of objects providing for remote
                monitoring of the SNMP Message Processing and
                Dispatching process.
               "
   ::= { snmpMPDMIBGroups 1 }

END

The SNMPv3 Message Format

This section defines the SNMPv3 message format and the corresponding SNMP version 3 Message Processing Model (v3MP).

SNMPv3MessageSyntax DEFINITIONS IMPLICIT TAGS ::= BEGIN

   SNMPv3Message ::= SEQUENCE {
       -- identify the layout of the SNMPv3Message
       -- this element is in same position as in SNMPv1
       -- and SNMPv2c, allowing recognition
       msgVersion INTEGER { snmpv3 (3) },
       -- administrative parameters
       msgGlobalData HeaderData,
       -- security model-specific parameters
       -- format defined by Security Model
       msgSecurityParameters OCTET STRING,
       msgData  ScopedPduData
   }
   HeaderData ::= SEQUENCE {
       msgID      INTEGER (0..2147483647),
       msgMaxSize INTEGER (484..2147483647),
       msgFlags   OCTET STRING (SIZE(1)),
                  --              Please observe:
       msgSecurityModel INTEGER (0..2147483647)
   }
   ScopedPduData ::= CHOICE {
       plaintext    ScopedPDU,
       encryptedPDU OCTET STRING  -- encrypted scopedPDU value
   }
   ScopedPDU ::= SEQUENCE {
       contextEngineID  OCTET STRING,
       contextName      OCTET STRING,
       data             ANY -- e.g., PDUs as defined in RFC1905
   }

END

msgVersion

The msgVersion field is set to snmpv3(3) and identifies the message as an SNMP version 3 Message.

msgID

The msgID is used between two SNMP entities to coordinate request messages and responses, and by the v3MP to coordinate the processing of the message by different subsystem models within the architecture.

Values for msgID should be generated in a manner that avoids re-use of any outstanding values. Doing so provides protection against some replay attacks. One possible implementation strategy would be to use the low-order bits of snmpEngineBoots RFC2261 as the high-order portion of the msgID value and a monotonically increasing integer for the low-order portion of msgID.

Note that the request-id in a PDU is used by SNMP applications to identify the PDU; the msgID is used by the engine to identify the message which carries a PDU. The engine may need to identify the message even if decrypting of the PDU (and request-id) fails. No assumption should be made that the value of the msgID and the value of the request-id are equivalent.

msgMaxSize

The msgMaxSize field of the message conveys the maximum message size supported by the sender of the message, i.e., the maximum message size that the sender can accept when another SNMP engine sends an SNMP message (be it a response or any other message) to the sender of this message.

When an SNMP message is being generated, the msgMaxSize is provided by the SNMP engine which generates the message. At the receiving SNMP engine, the msgMaxSize is used to determine how big the Response to a Request message can be.

msgFlags

The msgFlags field of the message contains several bit fields which control processing of the message.

When the reportableFlag is one, a Report PDU must be returned to the sender under those conditions which can cause the generation of Report PDUs. When the reportableFlag is zero, then a Report PDU must not be sent. The reportableFlag must always be zero when the message contains a Report PDU, a response-type PDU (such as a Response PDU), or an unacknowledged notification-type PDU (such as an SNMPv2-trap PDU). The reportableFlag must always be one for a request-type PDU (such as a Get PDU) and an acknowledged notification-type PDU (such as an Inform PDU).

If the reportableFlag is set to one for a message containing a Report PDU, a response-type PDU (such as a Response PDU), or an unacknowledged notification-type PDU (such as an SNMPv2-trap PDU), then the receiver of that message must process it as though the reportableFlag had been set to zero.

If the reportableFlag is set to zero for a message containing a request-type PDU (such as a Get PDU) or an acknowledged notification- type PDU (such as an Inform PDU), then the receiver of that message must process it as though the reportableFlag had been set to one.

Report PDUs are engine-to-engine communications and are processed directly by the SNMPv3 Message Processing Model, and are generally not passed to applications for processing, unlike all other PDU types.

Note that the reportableFlag is a secondary aid in determining whether a Report PDU must be sent. It is only used in cases where the PDU portion of a message cannot be decoded, due to, for example, an incorrect ecryption key. If the PDU can be decoded, the PDU type forms the basis for decisions on sending Report PDUs.

The authFlag and privFlag portions of the msgFlags field are set by the sender to indicate the securityLevel that was applied to the message before it was sent on the wire. The receiver of the message must apply the same securityLevel when the message is received and the contents are being processed.

There are three securityLevels, namely noAuthNoPriv, which is less than authNoPriv, which is in turn less than authPriv. See the SNMP architecture document RFC2261 for details about the securityLevel.

a) authFlag

  If the authFlag is set to one, then the securityModel used by the
  SNMP engine which sent the message must identify the securityName
  on whose behalf the SNMP message was generated and must provide,
  in a securityModel-specific manner, sufficient data for the
  receiver of the message to be able to authenticate that
  identification.  In general, this authentication will allow the
  receiver to determine with reasonable certainty that the message
  was:
  -  sent on behalf of the principal associated with the
     securityName,
  -  was not redirected,
  -  was not modified in transit, and
  -  was not replayed.
  If the authFlag is zero, then the securityModel used by the SNMP
  engine which sent the message must identify the securityName on
  whose behalf the SNMP message was generated but it does not need
  to provide sufficient data for the receiver of the message to
  authenticate the identification, as there is no need to
  authenticate the message in this case.

b) privFlag

  If the privFlag is set, then the securityModel used by the SNMP
  engine which sent the message must also protect the scopedPDU in
  an SNMP message from disclosure, i.e., must encrypt/decrypt the
  scopedPDU. If the privFlag is zero, then the securityModel in use
  does not need to protect the data from disclosure.
  It is an explicit requirement of the SNMP architecture that if
  privacy is selected, then authentication is also required.  That
  means that if the privFlag is set, then the authFlag must also be
  set to one.
  The combination of the authFlag and the privFlag comprises a Level
  of Security as follows:
     authFlag zero, privFlag zero -> securityLevel is noAuthNoPriv
     authFlag zero, privFlag one  -> invalid combination
     authFlag one,  privFlag zero -> securityLevel is authNoPriv
     authFlag one,  privFlag one  -> securityLevel is authPriv

msgSecurityModel

The v3MP supports the concurrent existence of multiple Security Models to provide security services for SNMPv3 messages. The msgSecurityModel field in an SNMPv3 Message identifies which Security Model was used by the sender to generate the message and therefore which securityModel must be used by the receiver to perform security processing for the message. The mapping to the appropriate securityModel implementation within an SNMP engine is accomplished in an implementation-dependent manner.

msgSecurityParameters

The msgSecurityParameters field of the SNMPv3 Message is used for communication between the Security Model modules in the sending and receiving SNMP engines. The data in the msgSecurityParameters field is used exclusively by the Security Model, and the contents and format of the data is defined by the Security Model. This OCTET STRING is not interpreted by the v3MP, but is passed to the local implementation of the Security Model indicated by the msgSecurityModel field in the message.

scopedPduData

The scopedPduData field represents either the plain text scopedPDU if the privFlag in the msgFlags is zero, or it represents an encryptedPDU (encoded as an OCTET STRING) which must be decrypted by the securityModel in use to produce a plaintext scopedPDU.

scopedPDU

The scopedPDU contains information to identify an administratively unique context and a PDU. The object identifiers in the PDU refer to managed objects which are (expected to be) accessible within the specified context.

contextEngineID

The contextEngineID in the SNMPv3 message, uniquely identifies, within an administrative domain, an SNMP entity that may realize an instance of a context with a particular contextName.

For incoming messages, the contextEngineID is used to determine to which application the scopedPDU will be sent for processing.

For outgoing messages, the v3MP sets the contextEngineID to the value provided by the application in the request for a message to be sent.

contextName

The contextName field in an SNMPv3 message, in conjunction with the contextEngineID field, identifies the particular context associated with the management information contained in the PDU portion of the message. The contextName is unique within the SNMP entity specified by the contextEngineID, which may realize the managed objects referenced within the PDU. An application which originates a message provides the value for the contextName field and this value may be used during processing by an application at the receiving SNMP Engine.

data

The data field of the SNMPv3 Message contains the PDU. Among other things, the PDU contains the PDU type that is used by the v3MP to determine the type of the incoming SNMP message. The v3MP specifies that the PDU must be one of those specified in RFC1905.

Elements of Procedure for v3MP

This section describes the procedures followed by an SNMP engine when generating and processing SNMP messages according to the SNMPv3 Message Processing Model.

Please note, that for the sake of clarity and to prevent the text from being even longer and more complicated, some details were omitted from the steps below.

  a) Some steps specify that when some error conditions are
     encountered when processing a received message, a message
     containing a Report PDU is generated and the received message
     is discarded without further processing.  However, a Report-PDU
     must not be generated unless the reportableFlag is set in the
     received message.
  b) The elements of procedure do not always explicitly indicate
     when state information needs to be released. The general rule
     is that if state information is available when a message is to
     be "discarded without further processing", then the state
     information must also be released at that same time.

Prepare an Outgoing SNMP Message

This section describes the procedure followed to prepare an SNMPv3 message from the data elements passed by the Message Dispatcher.

1) The Message Dispatcher may request that an SNMPv3 message

  containing a GetRequest-PDU, GetNextRequest-PDU, GetBulkRequest-
  PDU, SetRequest-PDU, InformRequest-PDU, or SNMPv2-Trap-PDU be
  prepared for sending.
  a) It makes such a request according to the abstract service
     primitive:
     statusInformation =           -- success or errorIndication
       prepareOutgoingMessage(
       IN   transportDomain        -- requested transport domain
       IN   transportAddress       -- requested destination address
       IN   messageProcessingModel -- typically, SNMP version
       IN   securityModel          -- Security Model to use
       IN   securityName           -- on behalf of this principal
       IN   securityLevel          -- Level of Security requested
       IN   contextEngineID        -- data from/at this entity
       IN   contextName            -- data from/in this context
       IN   pduVersion             -- version of the PDU
       IN   PDU                    -- SNMP Protocol Data Unit
       IN   expectResponse         -- TRUE or FALSE
       IN   sendPduHandle          -- the handle for matching
                                   -- incoming responses
       OUT  destTransportDomain    -- destination transport domain
       OUT  destTransportAddress   -- destination transport address
       OUT  outgoingMessage        -- the message to send
       OUT  outgoingMessageLength  -- the length of the message
       )
  b) A unique msgID is generated.  The number used for msgID should
     not have been used recently, and must not be the same as was
     used for any outstanding request.
     * SNMPv3 does not use the values of expectResponse or
     pduVersion.

2) The Message Dispatcher may request that an SNMPv3 message

  containing a Response-PDU or Report-PDU be prepared for sending.
  a) It makes such a request according to the abstract service
     primitive:
     result =                        -- SUCCESS or FAILURE
     prepareResponseMessage(
      IN   messageProcessingModel   -- typically, SNMP version
      IN   securityModel            -- same as on incoming request
      IN   securityName             -- same as on incoming request
      IN   securityLevel            -- same as on incoming request
      IN   contextEngineID          -- data from/at this SNMP entity
      IN   contextName              -- data from/in this context
      IN   pduVersion               -- version of the PDU
      IN   PDU                      -- SNMP Protocol Data Unit
      IN   maxSizeResponseScopedPDU -- maximum size of Response PDU
      IN   stateReference           -- reference to state
                                    -- information presented with
                                    -- the request
      IN   statusInformation        -- success or errorIndication
                                    -- error counter OID and value
                                    -- when errorIndication
      OUT  transportDomain          -- destination transport domain
      OUT  transportAddress         -- destination transport address
      OUT  outgoingMessage          -- the message to send
      OUT  outgoingMessageLength    -- the length of the message
      )
  b) The cached information for the original request is retrieved
     via the stateReference, including
              - msgID,
              - contextEngineID,
              - contextName,
              - securityModel,
              - securityName,
              - securityLevel,
              - securityStateReference,
              - reportableFlag,
              - transportDomain, and
              - transportAddress.
     The SNMPv3 Message Processing Model does not allow cached data
     to be overridden, except by error indications as detailed in
     (3) below.

3) If statusInformation contains values for an OID/value combination

  (potentially also containing a securityLevel value,
  contextEngineID value, or contextName value), then
  a) If reportableFlag is zero, then the original message is
     discarded, and no further processing is done. A result of
     FAILURE is returned. SNMPv3 Message Processing is complete.
  b) If a PDU is provided, it is the PDU from the original request.
     If possible, extract the request-id.
  c) A Report PDU is prepared:
     1) the varBindList is set to contain the OID and value from the
        statusInformation
     2) error-status is set to 0
     3) error-index is set to 0.
     4) request-id is set to the value extracted in step b)
        Otherwise, request-id is set to 0
  d) The errorIndication in statusInformation may be accompanied by
     a securityLevel value, a contextEngineID value, or a
     contextName value.
     1) If statusInformation contains a value for securityLevel,
        then securityLevel is set to that value, otherwise it is set
        to noAuthNoPriv.
     2) If statusInformation contains a value for contextEngineID,
        then contextEngineID is set to that value, otherwise it is
        set to the value of this entity's snmpEngineID.
     3) If statusInformation contains a value for contextName, then
        contextName is set to that value, otherwise it is set to the
        default context of "" (zero-length string).
  e) PDU is set to refer to the new Report-PDU.  The old PDU is
     discarded.
  f) Processing continues with step 6) below.

4) If contextEngineID is not yet determined, then the contextEngineID

  is determined, in an implementation-dependent manner, possibly
  using the transportDomain and transportAddress.

5) If the contextName is not yet determined, the contextName is set

  to the default context.

6) A scopedPDU is prepared from the contextEngineID, contextName, and

  PDU.

7) msgGlobalData is constructed as follows

  a) The msgVersion field is set to snmpv3(3).
  b) msgID is set as determined in step 1 or 2 above.
  c) msgMaxSize is set to an implementation-dependent value.
  d) msgFlags are set as follows:
     -  If securityLevel specifies noAuthNoPriv, then authFlag and
        privFlag are both set to zero.
     -  If securityLevel specifies authNoPriv, then authFlag is set
        to one and privFlag is set to zero.
     -  If securityLevel specifies authPriv, then authFlag is set to
        one and privFlag is set to one.
     -  If the PDU is a Response-PDU, Report-PDU or SNMPv2-Trap-PDU,
        then the reportableFlag is set to zero.
     -  If the PDU is a GetRequest-PDU, GetNextRequest-PDU,
        GetBulkRequest-PDU, SetRequest-PDU, or InformRequest-PDU
        then the reportableFlag is set to one.
     -  All other msgFlags bits are set to zero.
  e) msgSecurityModel is set to the value of securityModel

8) If the PDU is a Response-PDU or Report-PDU, then

  a) The specified Security Model is called to generate the message
     according to the primitive:
     statusInformation =
       generateResponseMsg(
       IN   messageProcessingModel -- SNMPv3 Message Processing
                                   -- Model
       IN   globalData             -- msgGlobalData from step 7
       IN   maxMessageSize         -- from msgMaxSize (step 7c)
       IN   securityModel          -- as determined in step 7e
       IN   securityEngineID       -- the value of snmpEngineID
       IN   securityName           -- on behalf of this principal
       IN   securityLevel          -- for the outgoing message
       IN   scopedPDU              -- as prepared in step 6)
       IN   securityStateReference -- as determined in step 2
       OUT  securityParameters     -- filled in by Security Module
       OUT  wholeMsg               -- complete generated message
       OUT  wholeMsgLength         -- length of generated message
       )
     If, upon return from the Security Model, the statusInformation
     includes an errorIndication, then any cached information about
     the outstanding request message is discarded, and an
     errorIndication is returned, so it can be returned to the
     calling application. SNMPv3 Message Processing is complete.
  b) A SUCCESS result is returned. SNMPv3 Message Processing is
     complete.

9) If the PDU is a GetRequest-PDU, GetNextRequest-PDU,

  GetBulkRequest-PDU, SetRequest-PDU, InformRequest-PDU, or or
  SNMPv2-Trap-PDU, then
  a) If the PDU is an SNMPv2-Trap-PDU, then securityEngineID is set
     to the value of this entity's snmpEngineID.
     Otherwise, the snmpEngineID of the target entity is determined,
     in an implementation-dependent manner, possibly using
     transportDomain and transportAddress.  The value of
     securityEngineID is set to the value of the target entity's
     snmpEngineID.
  b) The specified Security Model is called to generate the message
     according to the primitive:
     statusInformation =
      generateRequestMsg(
      IN  messageProcessingModel -- SNMPv3 Message Processing Model
      IN  globalData             -- msgGlobalData, from step 7
      IN  maxMessageSize         -- from msgMaxSize in step 7 c)
      IN  securityModel          -- as provided by caller
      IN  securityEngineID       -- authoritative SNMP entity
      IN  securityName           -- as provided by caller
      IN  securityLevel          -- as provided by caller
      IN  snmpEngineID           -- as determined in step 9 a)
      IN  scopedPDU              -- as prepared in step 6
      OUT securityParameters     -- filled in by Security Module
      OUT wholeMsg               -- complete generated message
      OUT wholeMsgLength         -- length of the generated message
      )
     If, upon return from the Security Model, the statusInformation
     includes an errorIndication, then the message is discarded, and
     the errorIndication is returned, so it can be returned to the
     calling application, and no further processing is done.
     SNMPv3 Message Processing is complete.
  c) Information about the outgoing message is cached, and a
     stateReference is created (implementation-specific).
     Information to be cached includes the values of:
                  - sendPduHandle
                  - msgID
                  - snmpEngineID
                  - securityModel
                  - securityName
                  - securityLevel
                  - contextEngineID
                  - contextName
  d) A SUCCESS result is returned.  SNMPv3 Message Processing is
     complete.

Prepare Data Elements from an Incoming SNMP Message

This section describes the procedure followed to extract data from an SNMPv3 message, and to prepare the data elements required for further processing of the message by the Message Dispatcher.

1) The message is passed in from the Message Dispatcher according to

  the abstract service primitive:
   result =                         -- SUCCESS or errorIndication
     prepareDataElements(
     IN  transportDomain          -- origin transport domain
     IN  transportAddress         -- origin transport address
     IN  wholeMsg                 -- as received from the network
     IN  wholeMsgLength           -- as received from the network
     OUT messageProcessingModel   -- typically, SNMP version
     OUT securityModel            -- Security Model to use
     OUT securityName             -- on behalf of this principal
     OUT securityLevel            -- Level of Security requested
     OUT contextEngineID          -- data from/at this entity
     OUT contextName              -- data from/in this context
     OUT pduVersion               -- version of the PDU
     OUT PDU                      -- SNMP Protocol Data Unit
     OUT pduType                  -- SNMP PDU type
     OUT sendPduHandle            -- handle for matched request
     OUT maxSizeResponseScopedPDU -- maximum size of Response PDU
     OUT statusInformation        -- success or errorIndication
                                  -- error counter OID and value
                                  -- when errorIndication
     OUT stateReference           -- reference to state information
                                  -- to be used for a possible
     )                            -- Response

2) If the received message is not the serialization (according to

  the conventions of RFC1906) of an SNMPv3Message value, then the
  snmpInASNParseErrs counter RFC1907 is incremented, the message
  is discarded without further processing, and a FAILURE result is
  returned. SNMPv3 Message Processing is complete.

3) The values for msgVersion, msgID, msgMaxSize, msgFlags,

  msgSecurityModel, msgSecurityParameters, and msgData are extracted
  from the message.

4) If the value of the msgSecurityModel component does not match a

  supported securityModel, then the snmpUnknownSecurityModels
  counter is incremented, a Report PDU is generated, the message is
  discarded without further processing, and a FAILURE result is
  returned. SNMPv3 Message Processing is complete.

5) The securityLevel is determined from the authFlag and the

  privFlag bits of the msgFlags component as follows:
  a) If the authFlag is not set and the privFlag is not set, then
     securityLevel is set to noAuthNoPriv.
  b) If the authFlag is set and the privFlag is not set, then
     securityLevel is set to authNoPriv.
  c) If the authFlag is set and the privFlag is set, then
     securityLevel is set to authPriv.
  d) If the authFlag is not set and privFlag is set, then the
     snmpInvalidMsgs counter is incremented, a Report PDU is
     generated, the message is discarded without further processing,
     and a FAILURE result is returned. SNMPv3 Message Processing is
     complete.

6) The security module implementing the Security Model as specified

  by the securityModel component is called for authentication and
  privacy services.  This is done according to the abstract service
  primitive:
   statusInformation =            -- errorIndication or success
                                  -- error counter OID and
                                  -- value if error
     processIncomingMsg(
     IN  messageProcessingModel   -- SNMPv3 Message Processing Model
     IN  expectResponse           -- TRUE or FALSE
     IN  maxMessageSize           -- of the sending SNMP entity
     IN  securityParameters       -- for the received message
     IN  securityModel            -- for the received message
     IN  securityLevel            -- Level of Security
     IN  wholeMsg                 -- as received on the wire
     IN  wholeMsgLength           -- length as received on the wire
     OUT securityEngineID         -- authoritative SNMP entity
     OUT securityName             -- identification of the principal
     OUT scopedPDU,               -- message (plaintext) payload
     OUT maxSizeResponseScopedPDU -- maximum size of Response PDU
     OUT securityStateReference   -- reference to security state
     )                            -- information, needed for
                                  -- response
  If an errorIndication is returned by the security module, then
  a) If statusInformation contains values for an OID/value pair,
     then a Report PDU is generated.
     1) If the scopedPDU has been returned from ProcessIncomingMsg
        then determine contextEngineID, contextName, and PDU.
     2) Information about the message is cached and a
        stateReference is created (implementation-specific).
        Information to be cached includes the values of:
                      msgVersion,
                      msgID,
                      securityLevel,
                      msgFlags,
                      msgMaxSize,
                      securityModel,
                      maxSizeResponseScopedPDU,
                      securityStateReference
     3) Request that a Report-PDU be prepared and sent, according
        to the abstract service primitive:
         result =                     -- SUCCESS or FAILURE
         returnResponsePDU(
         IN  messageProcessingModel   -- SNMPv3(3)
         IN  securityModel            -- same as on incoming request
         IN  securityName             -- from ProcessIncomingMsg
         IN  securityLevel            -- same as on incoming request
         IN  contextEngineID          -- from step 6 a) 1)
         IN  contextName              -- from step 6 a) 1)
         IN  pduVersion               -- SNMPv2-PDU
         IN  PDU                      -- from step 6 a) 1)
         IN  maxSizeResponseScopedPDU -- from ProcessIncomingMsg
         IN  stateReference           -- from step 6 a) 2)
         IN  statusInformation        -- from ProcessIncomingMsg
         OUT transportDomain          -- destination's transport
                                      -- domain
         OUT transportAddress         -- destination's transport
                                      -- address
         OUT outgoingMessage          -- the message to send
         OUT outgoingMessageLength    -- the length of the message
         )
  b) The incoming message is discarded without further processing,
     and a FAILURE result is returned. SNMPv3 Message Processing is
     complete.

7) The scopedPDU is parsed to extract the contextEngineID, the

  contextName and the PDU.  If any parse error occurs, then the
  snmpInASNParseErrs counter RFC1907 is incremented, the security
  state information is discarded, the message is discarded without
  further processing, and a FAILURE result is returned. SNMPv3
  Message Processing is complete.

8) The pduVersion is set to an SNMPv2-PDU.

9) The pduType is determined, in an implementation-dependent manner,

  to be:
           - a GetRequest-PDU,
           - a GetNextRequest-PDU,
           - a GetBulkRequest-PDU,
           - a SetRequest-PDU,
           - an InformRequest-PDU,
           - an SNMPv2-Trap-PDU,
           - a Response-PDU, or
           - a Report-PDU.

10) If the pduType is a Response-PDU or Report-PDU, then

   a) The value of the msgID component is used to find the cached
      information for a corresponding outstanding Request message.
      If no such outstanding Request message is found, then the
      security state information is discarded, the message is
      discarded without further processing, and a FAILURE result is
      returned. SNMPv3 Message Processing is complete.
   b) sendPduHandle is retrieved from the cached information.
   Otherwise, sendPduHandle is set to <none>, an implementation
   defined value.

11) If the pduType is a Report-PDU, then

   a) statusInformation is created using the contents of the
      Report-PDU, in an implementation-dependent manner. This
      statusInformation will be forwarded to the application
      associated with the sendPduHandle.
   b) Any cached information about the outstanding Request message
      message is discarded.
   c) The security state information for this incoming message is
      discarded.
   d) stateReference is set to <none>
   e) A SUCCESS result is returned. SNMPv3 Message Processing is
       complete.

12) If the pduType is a Response-PDU, then

   a) The cached data for the outstanding request, referred to by
      stateReference, is retrieved, including
                   - snmpEngineID
                   - securityModel
                   - securityName
                   - securityLevel
                   - contextEngineID
                   - contextName
   b) If the values extracted from the incoming message differ from
      the cached data, then the security state information is
      discarded, any cached information about the outstanding
      Request message is discarded, the incoming message is
      discarded without further processing, and a FAILURE result is
      returned.  SNMPv3 Message Processing is complete.
   c) Otherwise, any cached information about the outstanding
      Request message is discarded, and stateReference is set to
      <none>.
   d) A SUCCESS result is returned. SNMPv3 Message Processing is
      complete.

13) If the pduType is a GetRequest-PDU, GetNextRequest-PDU,

   GetBulkRequest-PDU, SetRequest-PDU, or InformRequest-PDU, then
   a) If the value of securityEngineID is not equal to the value of
      snmpEngineID, then the security state information is
      discarded, any cached information about the outstanding
      Request message is discarded, the incoming message is
      discarded without further processing, and a FAILURE result is
      returned.  SNMPv3 Message Processing is complete.
   b) Information about the message is cached and a stateReference
      is created (implementation-specific).  Information to be
      cached includes the values of:
                    msgVersion,
                    msgID,
                    securityLevel,
                    msgFlags,
                    msgMaxSize,
                    securityModel,
                    maxSizeResponseScopedPDU,
                    securityStateReference
   c) A SUCCESS result is returned. SNMPv3 Message Processing is
      complete.

14) If the pduType is an SNMPv2-Trap-PDU, then A SUCCESS result is

   returned. SNMPv3 Message Processing is complete.

Intellectual Property

The IETF takes no position regarding the validity or scope of any intellectual property or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; neither does it represent that it has made any effort to identify any such rights. Information on the IETF's procedures with respect to rights in standards-track and standards-related documentation can be found in BCP-11. Copies of claims of rights made available for publication and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementors or users of this specification can be obtained from the IETF Secretariat.

The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights which may cover technology that may be required to practice this standard. Please address the information to the IETF Executive Director.

Acknowledgements

This document is the result of the efforts of the SNMPv3 Working Group. Some special thanks are in order to the following SNMPv3 WG members:

  Dave Battle (SNMP Research, Inc.)
  Uri Blumenthal (IBM T.J. Watson Research Center)
  Jeff Case (SNMP Research, Inc.)
  John Curran (BBN)
  T. Max Devlin (Hi-TECH Connections)
  John Flick (Hewlett Packard)
  David Harrington (Cabletron Systems Inc.)
  N.C. Hien (IBM T.J. Watson Research Center)
  Dave Levi (SNMP Research, Inc.)
  Louis A Mamakos (UUNET Technologies Inc.)
  Paul Meyer (Secure Computing Corporation)
  Keith McCloghrie (Cisco Systems)
  Russ Mundy (Trusted Information Systems, Inc.)
  Bob Natale (ACE*COMM Corporation)
  Mike O'Dell (UUNET Technologies Inc.)
  Dave Perkins (DeskTalk)
  Peter Polkinghorne (Brunel University)
  Randy Presuhn (BMC Software, Inc.)
  David Reid (SNMP Research, Inc.)
  Shawn Routhier (Epilogue)
  Juergen Schoenwaelder (TU Braunschweig)
  Bob Stewart (Cisco Systems)
  Bert Wijnen (IBM T.J. Watson Research Center)

The document is based on recommendations of the IETF Security and Administrative Framework Evolution for SNMP Advisory Team. Members of that Advisory Team were:

  David Harrington (Cabletron Systems Inc.)
  Jeff Johnson (Cisco Systems)
  David Levi (SNMP Research Inc.)
  John Linn (Openvision)
  Russ Mundy (Trusted Information Systems) chair
  Shawn Routhier (Epilogue)
  Glenn Waters (Nortel)
  Bert Wijnen (IBM T. J. Watson Research Center)

As recommended by the Advisory Team and the SNMPv3 Working Group Charter, the design incorporates as much as practical from previous RFCs and drafts. As a result, special thanks are due to the authors of previous designs known as SNMPv2u and SNMPv2*:

Jeff Case (SNMP Research, Inc.) David Harrington (Cabletron Systems Inc.) David Levi (SNMP Research, Inc.) Keith McCloghrie (Cisco Systems) Brian O'Keefe (Hewlett Packard) Marshall T. Rose (Dover Beach Consulting) Jon Saperia (BGS Systems Inc.) Steve Waldbusser (International Network Services) Glenn W. Waters (Bell-Northern Research Ltd.)

10. Security Considerations

The Dispatcher coordinates the processing of messages to provide a level of security for management messages and to direct the SNMP PDUs to the proper SNMP application(s).

A Message Processing Model, and in particular the V3MP defined in this document, interacts as part of the Message Processing with Security Models in the Security Subsystem via the abstract service interface primitives defined in RFC2261 and elaborated above.

The level of security actually provided is primarily determined by the specific Security Model implementation(s) and the specific SNMP application implementation(s) incorporated into this framework. Applications have access to data which is not secured. Applications should take reasonable steps to protect the data from disclosure, and when they send data across the network, they should obey the securityLevel and call upon the services of an Access Control Model as they apply access control.

The values for the msgID element used in communication between SNMP entities must be chosen to avoid replay attacks. The values do not need to be unpredictable; it is sufficient that they not repeat.

11. References

RFC1901 Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,

  "Introduction to Community-based SNMPv2",
  RFC 1901, January 1996.

RFC1902 Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,

  "Structure of Management Information for
  Version  2 of the Simple Network Management Protocol (SNMPv2)",
  RFC 1902, January 1996.

RFC1905 Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,

  "Protocol Operations for Version 2 of the
  Simple Network Management Protocol (SNMPv2)", RFC 1905, January
  1996.

RFC1906 Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,

  "Transport Mappings for Version 2 of the
  Simple Network Management Protocol (SNMPv2)", RFC 1906, January
  1996.

RFC1907 Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,

  "Management Information Base for Version 2
  of the Simple Network Management Protocol (SNMPv2)", RFC 1907
  January 1996.

RFC1908 Case, J., McCloghrie, K., Rose, M., and S. Waldbusser,

  "Coexistence between Version 1 and Version
  2 of the Internet-standard Network Management Framework", RFC
  1908, January 1996.

[[[RFC2028|RFC 2028]]] Hovey, R., and S. Bradner, "The Organizations Involved in

  the IETF Standards Process", BCP 11, RFC 2028, October 1996.

RFC2119 Bradner, S., "Key words for use in RFCs to Indicate

  Requirement Levels", RFC 2119, BCP 14, March 1997.

RFC2261 Harrington, D., Presuhn, R., and B. Wijnen, "An

  Architecture for describing SNMP Management Frameworks",
  RFC 2261, January 1998.

RFC2264 Blumenthal, U., and B. Wijnen, "The User-Based

  Security Model for Version 3 of the Simple Network
  Management Protocol (SNMPv3)", RFC 2264, January 1998.

RFC2265 Wijnen, B., Presuhn, R., and K. McCloghrie,

  "View-based Access Control Model for the Simple
  Network Management Protocol (SNMP)", RFC 2265, January 1998.

RFC2263 Levi, D., Meyer, P., and B. Stewart, "SNMPv3

  Applications", RFC 2263, January 1998.

12. Editors' Addresses

Jeffrey Case SNMP Research, Inc. 3001 Kimberlin Heights Road Knoxville, TN 37920-9716 USA

Phone: +1 423-573-1434 EMail: [email protected]

Dave Harrington Cabletron Systems, Inc Post Office Box 5005 Mail Stop: Durham 35 Industrial Way Rochester, NH 03867-5005 USA

Phone: +1 603-337-7357 EMail: [email protected]

Randy Presuhn BMC Software, Inc. 1190 Saratoga Avenue Suite 130 San Jose, CA 95129 USA

Phone: +1 408-556-0720 EMail: [email protected]

Bert Wijnen IBM T. J. Watson Research Schagen 33 3461 GL Linschoten Netherlands

Phone: +31 348-432-794 EMail: [email protected]

13. Full Copyright Statement

Copyright (C) The Internet Society (1997). All Rights Reserved.

This document and translations of it may be copied and furnished to others, and derivative works that comment on or otherwise explain it or assist in its implementation may be prepared, copied, published and distributed, in whole or in part, without restriction of any kind, provided that the above copyright notice and this paragraph are included on all such copies and derivative works. However, this document itself may not be modified in any way, such as by removing the copyright notice or references to the Internet Society or other Internet organizations, except as needed for the purpose of developing Internet standards in which case the procedures for copyrights defined in the Internet Standards process must be followed, or as required to translate it into languages other than English.

The limited permissions granted above are perpetual and will not be revoked by the Internet Society or its successors or assigns.

This document and the information contained herein is provided on an "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.