Network Working Group K. Tesink Request for Comments: 2558 Telcordia Technologies Obsoletes: 1595 March 1999 Category: Standards Track

                 Definitions of Managed Objects
                for the SONET/SDH Interface Type

Status of this Memo

This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited.

Copyright Notice

Copyright (C) The Internet Society (1999). All Rights Reserved.

Abstract

This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in TCP/IP-based internets. In particular, it defines objects for managing Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH) interfaces. This document is a companion to the documents that define Managed Objects for the DS1/E1/DS2/E2 and DS3/E3 Interface Types [24][25].

Textual Conventions used in this MIB are defined in [6] and [36].

This memo replaces RFC 1595 [30]. Changes relative to RFC 1595 are summarized in the MIB module's REVISION clause.

3.2 Use of ifTable for SONET/SDH Medium/Section/Line

The SNMP Network Management Framework

The SNMP Management Framework presently consists of five major components:

0 An overall architecture, described in RFC 2271 [1].

0 Mechanisms for describing and naming objects and events for the

    purpose of management.  The first version of this Structure of
    Management Information (SMI) is called SMIv1 and described in
    STD 16, RFC 1155 [2], STD 16, RFC 1212 [3] and RFC 1215 [4].
    The second version, called SMIv2, is described in RFC 1902 [5],
    RFC 1903 [6] and RFC 1904 [7].

0 Message protocols for transferring management information. The

    first version of the SNMP message protocol is called SNMPv1 and
    described in STD 15, RFC 1157 [8].  A second version of the SNMP
    message protocol, which is not an Internet standards track
    protocol, is called SNMPv2c and described in RFC 1901 [9] and
    RFC 1906 [10].  The third version of the message protocol is
    called SNMPv3 and described in RFC 1906 [10], RFC 2272 [11] and
    RFC 2274 [12].

0 Protocol operations for accessing management information. The

    first set of protocol operations and associated PDU formats is
    described in STD 15, RFC 1157 [8].  A second set of protocol
    operations and associated PDU formats is described in RFC 1905
    [13].

0 A set of fundamental applications described in RFC 2273 [14] and

    the view-based access control mechanism described in RFC 2275
    [15].

Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. Objects in the MIB are defined using the mechanisms defined in the SMI.

This memo specifies a MIB module that is compliant to the SMIv2. A MIB conforming to the SMIv1 can be produced through the appropriate translations. The resulting translated MIB must be semantically equivalent, except where objects or events are omitted because no translation is possible (e.g., use of Counter64). Some machine readable information in SMIv2 will be converted into textual descriptions in SMIv1 during the translation process. However, this loss of machine readable information is not considered to change the semantics of the MIB.

Overview

These objects are used when the particular media being used to realize an interface is a SONET/SDH interface. At present, this applies to these values of the ifType variable in the Internet- standard MIB:

    sonet (39), sonetPath (50), sonetVT (51)

The definitions contained herein are based on the SONET/SDH specifications in ANSI T1.105 and T1.106-1988 [19][20][21] and CCITT G.707, 708, 709, and G.783 [26][27][28][29].

Use of the ifTable

This section specifies how the MIB II interfaces group, as defined in [23], is used for SONET/SDH interfaces. The SONET/SDH layers support several multiplexing possibilities.

For example in SONET, an Synchronous Transport Signal 3 (STS-3) has 3 SONET Paths, and a STS-3c has 1 SONET Path. Another example could be a STS-12 having 4 SONET STS-3c Paths. Similarly, a SONET Synchronous Payload Envelope (SPE) can carry many Virtual Tributaries (VTs), for example, one SONET SPE can carry 28 VT1.5s. It is important to note that an SPE and a VT in SONET is collectively referred to as a Virtual Container (VC) in SDH. Also, an STS is called Synchronous Transport Module (STM) in SDH.

Not all SONET/SDH equipment terminates all SONET/SDH layers. For example, a SONET/SDH STE regenerator terminates SONET/SDH Sections only, and is transparent for all layers above that. SONET/SDH Add- Drop multiplexers and Digital Cross Connect Systems terminate SONET/SDH Lines. SONET/SDH Terminal Multiplexers may also terminate SONET/SDH Paths and VTs/VCs.

MIB II [16], as extended by [23], accommodates these cases by appropriate use of the MIB II system group, and the interfaces group. The system group can name and describe the type of managed resource. The interfaces group defines which SONET/SDH layers apply, how these layers are configured and multiplexed. This is achieved by proper representation of SONET/SDH Layers by ifEntries as defined in [23], as follows:

             _____________________________
            |             |          |    |  >
            |             |          |    |  |
            |             |          |    |  |
            |_____________|__________|____|  >
            |               |      |      |  >
            |               |      |      |  |
            |               |      |      |  |
            |_______________|______|______|  >
            |                             |  >
            |                             |  |
            |    Line                     |  |
            |                             |  |
            |_____________________________|  |
            |                             |  |
            |                             |  |
            |    Section Layer            |   > 1 ifEntry
            |                             |  |
            |_____________________________|  |
            |                             |  |
            |                             |  |
            |    Physical Medium Layer    |  |
            |                             |  |
            |_____________________________|  >
            Use of ifTable for a SONET/SDH port

The exact configuration and multiplexing of the layers is maintained in the ifStackTable [23].

Use of ifTable for SONET/SDH Medium/Section/Line Layer

Only the ifGeneralInformationGroup needs to be supported.

ifTable Object Use for combined SONET/SDH

                 Medium/Section/Line Layer
==========================================================
ifIndex           Interface index.
ifDescr           SONET/SDH Medium/Section/Line
ifType            sonet(39)
ifSpeed           Speed of line rate for SONET/SDH,
                  (e.g., 155520000 bps).
ifPhysAddress     The value of the Circuit Identifier.
                  If no Circuit Identifier has been assigned
                  this object should have an octet string with
                  zero length.
ifAdminStatus     Supports read-only access.
                  The desired administrative status of the
                  interface.
ifOperStatus      The value testing(3) is not used.
                  This object assumes the value down(2),
                  if the objects sonetSectionCurrentStatus
                  and sonetLineCurrentStatus have
                  any other value than sonetSectionNoDefect(1)
                  and sonetLineNoDefect(1), respectively.
ifLastChange      sysUpTime at the last change in ifOperStatus.
ifName            Textual name of the interface or an OCTET STRING
                  of zero length.
ifLinkUpDownTrapEnable   Default value is enabled(1).
                         Just read-only access may be supported.
ifHighSpeed       Speed of line in Mega-bits per second
                  (e.g., 155 Mbps)
ifConnectorPresent Set to true(1).
ifAlias            The (non-volatile) alias name for this interface
                   as assigned by the network manager.

Use of ifTable for SONET/SDH Paths

Only the ifGeneralInformationGroup needs to be supported.

ifTable Object Use for SONET/SDH Paths

=============================
ifIndex           Interface index.
ifDescr           SONET/SDH Path
ifType            sonetPath(50)
ifSpeed           set to speed of SONET/SDH path
                  (e.g., an STS-1 path has a
                  rate of 50112000 bps.)
ifPhysAddress     Circuit Identifier or OCTET STRING of zero length.
ifAdminStatus     Supports read-only access.
                  The desired administrative status of the
                  interface.
ifOperStatus      This object assumes the value down(2),
                  if the object sonetPathCurrentStatus has
                  any other value than sonetPathNoDefect(1).
ifLastChange      sysUpTime at the last change in ifOperStatus.
ifName            Textual name of the interface or an OCTET STRING
                  of zero length.
ifLinkUpDownTrapEnable   Default value is disabled(2).
                         Just read-only access may be supported.
ifHighSpeed       Set to rate of SONET/SDH path
                  in Mega-bits per second.
ifConnectorPresent Set to false(2).
ifAlias            The (non-volatile) alias name for this interface
                   as assigned by the network manager.

Use of ifTable for SONET/SDH VTs/VCs

Only the ifGeneralInformationGroup needs to be supported.

ifTable Object Use for SONET/SDH VTs/VCs

===============================
ifIndex           Interface index.
ifDescr           SONET/SDH VT/VC
ifType            sonetVT(51)
ifSpeed           Set to speed of VT/VC
                  (e.g., a VT1.5 has a rate of
                  1728000 bps.)
ifPhysAddress     Circuit Identifier or OCTET STRING of zero length.
ifAdminStatus     Supports read-only access.
                  The desired administrative status of the
                  interface.
ifOperStatus      This object assumes the value down(2),
                  if the object sonetVTCurrentStatus has
                  any other value than sonetVTNoDefect(1).
ifLastChange      sysUpTime at the last change in ifOperStatus.
ifName            Textual name of the interface or an OCTET STRING
                  of zero length.
ifLinkUpDownTrapEnable   Default value is disabled(2).
                         Just read-only access may be supported.
ifHighSpeed       Set to rate of VT in Mega-bits per second.
ifConnectorPresent Set to false(2).
ifAlias            The (non-volatile) alias name for this interface
                   as assigned by the network manager.

SONET/SDH Terminology

The terminology used in this document to describe error conditions on a SONET circuit as monitored by a SONET system are from the T1.231 [22][31][35]. The terminology used in this document to describe error conditions on a SDH circuit as monitored by a SDH system are from the CCITT G.783 [29]. Only the SONET Performance Monitoring terminology is defined in this document. The definitions for SDH Performance Monitoring terms are similar but not identical, and they can be found in [29]. If the definition in this document does not match the definition in the T1.231 document, the implementer should follow the definition described in this document. In some cases other or additional references are used as compared with the ones cited above. This will be indicated in the text.

Section Loss Of Frame Failure (Out of Frame Event, Severely

    Errored Frame Defect)
    An Out of Frame (OOF) event (or Severely Errored Frame defect)
    is the occurrence of four contiguous errored frame alignment
    words.  A frame alignment word occupies the A1 and A2 bytes of
    an STS frame, and is defined in T1.105.  The SEF defect is
    terminated when two contiguous error-free frame words are
    detected.  Any implementation of the frame recovery circuitry
    which achieves realignment following an OOF within the 250
    microsecond (two frames) interval implied by this definition is
    acceptable.
    A Loss of Frame (LOF) defect is declared when an OOF/SEF defect
    persists for a period of 3 milliseconds.  The LOF defect is
    terminated when the incoming signal remains continuously in-
    frame for a period of 1 ms to 3 ms.
    A LOF failure is declared when the LOF defect persists for a
    period of 2.5 +/- 0.5 seconds, except when an LOS defect or
    failure is present.  The LOF failure is cleared when the LOS
    failure is declared, or when the LOF defect is absent for 10 +/-
    0.5 seconds.

Loss of Signal

    The Loss of Signal (LOS) defect is declared when no transitions
    are detected on the incoming signal (before descrambling).  The
    LOS defect is detected  upon observing 2.3 to 100 microseconds
    of no transitions.  The LOS defect is cleared after a 125
    microsecond interval (one frame) during which no LOS defect is
    detected.
    The LOS failure is declared when the LOS defect persists for a
    period of 2.5 +/- 0.5 seconds, or if LOS defect is present when
    the criteria for LOF failure declaration have been met.  The LOS
    failure is cleared when the LOS defect is absent for a period of
    10 +/- 0.5 seconds.  Declaration of LOS failure clears any
    existing LOF failure.  Clearing the LOS failure allows immediate
    declaration of the LOF failure if conditions warrant.

STS-Path Loss of Pointer

    A Loss of Pointer (LOP) defect is declared when either a valid
    pointer is not detected in eight consecutive frames, or when
    eight consecutive frames are detected with the New Data Flag
    (NDF) set to "1001" without a valid concatenation indicator (see
    ANSI T1.105).  A LOP defect is terminated when either a valid
    pointer with a normal NDF set to "0110", or a valid
    concatenation indicator is detected for three contiguous frames.
    Incoming STS-Path AIS shall not result in the declaration of a
    LOP defect.
    An STS-Path LOP failure is declared when the STS-Path LOP defect
    persists for a period of 2.5 +/- 0.5 seconds.  A STS-Path LOP
    failure is cleared when the STS-Path LOP defect is absent for 10
    +/- 0.5 seconds.

VT Loss of Pointer

    A VT LOP defect is declared when either a valid pointer is not
    detected in eight consecutive VT superframes, or when eight
    consecutive VT superframes are detected with the NDF set to
    "1001" without a valid concatenation indicator.  A VT LOP defect
    is terminated when either a valid pointer with a normal NDF set
    to "0110", or a valid concatenation indicator is detected for
    three contiguous VT superframes.  Incoming VT-Path AIS shall not
    result in declaring a VT LOP defect.
    A VT LOP failure is declared when the VT LOP defect persists for
    2.5 +/- 0.5 seconds.  A VT LOP failure is cleared when the VT
    LOP defect is absent for 10 +/- 0.5 seconds.

Line Alarm Indication Signal

    A Line Alarm Indication Signal (L-AIS) is defined in ANSI
    T1.105.  The following criteria are specific to the L-AIS
    defect:
    --  Line AIS defect is detected as a "111" pattern in bits 6, 7,
    and 8 of the K2 byte in five consecutive frames.
    --  Line AIS defect is terminated when bits 6, 7, and 8 of the
    K2 byte do not contain the code "111" for five consecutive
    frames.
    A Line AIS failure is declared when the Line AIS defect persists
    for a period of 20.5 +/- 0.5 seconds.  A Line AIS failure is
    cleared when the Line AIS defect is absent for 10 +/- 0.5
    seconds.

STS-Path Alarm Indication Signal

    The STS-Path Alarm Indication Signal (AIS) is defined in ANSI
    T1.105 as all ones in bytes H1, H2, and H3 as well as all ones
    in the entire STS SPE.  The following criteria are specific to
    the STS-Path AIS defect:
    -- STS-Path AIS defect is detected as all ones in bytes H1 and
    H2 in three contiguous frames.
    -- The STS-Path AIS defect is terminated when a valid STS
    Pointer is detected with the NDF set to "1001" (inverted) for
    one frame, or  "0110" (normal) for three contiguous frames.
    An STS-Path AIS failure is declared when the STS-Path AIS defect
    persists for 2.5 +/- 0.5 seconds.  An STS-Path AIS failure is
    cleared when the STS-Path AIS defect is absent for 10 +/- 0.5
    seconds.

VT-Path Alarm Indication Signal

    The VT-Path Alarm Indication Signal (AIS) is only applicable for
    VTs in the floating mode of operation.  VT-Path AIS is used to
    alert the downstream VT Path Terminating Entity (PTE) of an
    upstream failure.  Upon detection of a failure, Line AIS, or
    STS-Path AIS, an STS PTE will generate downstream VT-Path AIS if
    the STS Synchronous Payload Envelope (SPE) is carrying floating
    VTs.  VT-Path AIS is specified in ANSI T1.105 as all ones in
    bytes V1, V2, V3, and V4, as well as all ones in the entire VT
    SPE.  The following criteria are specific to VT-Path AIS defect:
    --  VT-Path AIS defect is detected by a VT PTE as all ones in
    bytes V1 and V2 in three contiguous VT superframes.
    --  VT-Path AIS defect is terminated when valid VT pointer with
    a valid VT size is detected with the NDF set to "1001"
    (inverted) for one VT superframe, or "0110" (normal) for three
    contiguous VT superframes are detected.
    A VT-Path AIS failure is declared when the VT-Path AIS defect
    persists for 2.5 +/- 0.5 seconds.  A VT-Path AIS failure is
    cleared when the VT-Path AIS defect is absent for 10 +/- 0.5
    seconds.

Line Remote Defect Indication

    Line Remote Defect Indication (RDI) (aka Line FERF) signal is
    the occurrence of a "110" pattern in bit positions 6, 7, and 8
    of the K2 byte in STS-1 #1 of the STS-N signal.  Line RDI is
    defined in ANSI T1.105.  The following criteria are specific to
    Line RDI defect:
    --  Line RDI defect is a "110" code in bits 6, 7, and 8 of the
    K2 byte of in STS-1 #1 in x consecutive frames, where x = 5
    [31][35] or 10 [35].
    --  Line RDI defect is terminated when any code other than "110"
    is detected in bits 6, 7, and 8 of the K2 byte in x consecutive
    frames, where x = 5 [31][35] or 10 [35].
    A Line Remote Failure Indication (RFI) failure is declared when
    the incoming Line RDI defects lasts for 2.5 +/- 0.5 seconds.
    The Line RFI failure is cleared when no Line RDI defects are
    detected for 10 +/- 0.5 seconds.

STS-Path Remote Defect Indication

    STS-Path RDI (aka STS-Path FERF) signal shall be generated
    within 100 milliseconds by the STS PTE upon detection of an AIS
    or LOP defect.  Transmission of the STS-Path RDI signal shall
    cease within 100 milliseconds when the STS PTE no longer detects
    STS-Path AIS or STS-Path LOP defect.  The STS-Path RDI  shall
    accurately report the presence or absence of STS-Path AIS or
    STS-Path LOP defects.  STS-Path RDI defect is defined in ANSI
    T1.105.  The following requirements are specific to the STS-Path
    RDI defect:
    --  STS-Path RDI is detected by all STS PTEs.  STS-Path RDI is
    detected by the upstream STS PTE as a "1" in bit five of the
    Path Status byte (G1) for x consecutive frames, where x = 5 [31]
    or 10 [35].
    --  Removal of STS-Path Remote Defect Indication is detected by
    a "0" in bit 5 of the G1 byte in x consecutive frames, where x =
    5 [31] or 10 [35].
    An STS-Path Remote Failure Indication (RFI) failure is declared
    when the incoming STS-Path RDI defects lasts for 2.5 +/- 0.5
    seconds.  The STS-Path RFI failure is cleared when no STS-Path
    RDI defects are detected for 10 +/- 0.5 seconds.

VT-Path Remote Defect Indication

    VT Path RDI (aka VT Path FERF) signal shall be generated within
    100 milliseconds by the VT PTE upon detection of a VT-Path AIS
    or LOP defect.  Transmission of the VT-Path RDI signal shall
    cease within 100 milliseconds when the VT PTE no longer detects
    VT-Path AIS or VT-Path LOP defect.  The VT-Path RDI  shall
    accurately report the presence or absence of VT-Path AIS or VT-
    Path LOP defects.  VT-Path RDI defect is defined in ANSI T1.105.
    The following requirements are specific to VT-Path RDI defect:
    --  VT-Path RDI defect is the occurrence of a "1" in bit 4 of
    the VT-Path Overhead byte (V5) in x consecutive frames, where x
    = 5 [31] or 10 [35].
    --  VT-Path RDI defect is terminated when a "0" is detected in
    bit 4 of the VT-Path Overhead byte (V5) for x consecutive
    frames, where x = 5 [31] or 10 [35].
    A VT-Path Remote Failure Indication (RFI) (derived) failure is
    declared when the incoming VT-Path RDI defects lasts for 2.5 +/-
    0.5 seconds.  The VT-Path RFI failure is cleared when no VT-Path
    RDI defects are detected for 10 +/- 0.5 seconds.

VT-Path Remote Failure Indication

    The VT-Path RFI signal is only required for the case of byte
    synch mapped DS1s where the DS1 frame bit is not mapped.  The
    VT-Path RFI is specified in ANSI T1.105, where it is currently
    called VT path yellow.  When provided, the VT-Path RFI signal is
    used to indicate the occurrence of far-end failures.  When the
    VT-Path RFI is not provided, far-end failures are derived from
    local timing of the VT-Path RDI defect.  The VT-Path RFI failure
    is declared within 5 ms of detecting the incoming VT-Path RFI
    Signal.  The VT-Path Remote Failure Indication (RFI) failure is
    cleared within 50 ms of detecting the removal of the incoming
    VT-Path RFI signal.

Coding Violation

    Coding Violations (CV) are Bit Interleaved Parity (BIP) errors
    that are detected in the incoming signal.  CV counters are
    incremented for each BIP error detected.  That is, each BIP-8
    can detect up to eight errors per STS-N frame, with each error
    incrementing the CV counter.  Section CVs shall be collected
    using the BIP-8 in the B1 byte located in the Section Overhead
    of STS-1 #1.  Line CVs shall be collected using the BIP-8s in B2
    bytes located in the Line Overhead of each STS-1 (since all CVs
    on an STS-N line are counted together, this is equivalent to
    counting each error in the BIP-8*N contained in the B2 bytes of
    the STS-N Line Overhead).  Thus, on an STS-N signal, up to 8 x N
    CVs may occur in each frame.  Path CVs shall be collected using
    the BIP-8 in the B3 byte of the STS-Path Overhead of the STS
    SPE.  VT CVs shall be collected using the BIP-2 in the V5
    overhead byte of the floating VT.

Errored Seconds

    At each layer, an Errored Second (ES) is a second with one or
    more Coding Violations at that layer OR one or more incoming
    defects (e.g., SEF, LOS, AIS, LOP) at that layer has occurred.

Severely Errored Seconds

    According to [22][31][32][34][35] at each layer, an Severely
    Errored Second (SES) is a second with x or more CVs at that
    layer, or a second during which at least one or more incoming
    defects at that layer has occurred.  The values of x in
    RFC1595[30] were based on [22] and [32] (see Appendix B). These
    values have subsequently been relaxed in [31][34][35]. In
    addition, according to G.826 [33] SESs are measured as a
    percentage of errored blocks.
    To deal with these sets of definitions this memo defines an
    object sonetSESThresholdSet that determines the correct
    interpretation of SES. For backward compatibility, if this
    object is not implemented the interpretation of Appendix B shall
    apply.  Otherwise, a more recent interpretation is suggested.
    An agent is not required to support all sets of definitions.
    Note that if a manager changes the value of this object all SES
    statistics collected prior to this change shall be invalidated.

Severely Errored Framing Seconds

    A Severely Errored Framing Second (SEFS) is a second containing
    one or more SEF events.  This counter is only counted at the
    Section Layer.

Unavailable Seconds

    At the Line, Path, and VT layers, an unavailable second is
    calculated by counting the number of seconds that the interface
    is unavailable.  At each layer, the SONET/SDH interface is said
    to be unavailable at the onset of 10 contiguous SESs.  The 10
    SESs are included in unavailable time.  Once unavailable, the
    SONET/SDH interface becomes available at the onset of 10
    contiguous seconds with no SESs.  The 10 seconds with no SESs
    are excluded from unavailable time.  With respect to the
    SONET/SDH error counts at each layer, all counters at that layer
    are incremented while the SONET/SDH interface is deemed
    available at that layer.  While the interface is deemed
    unavailable at that layer, the only count that is incremented is
    UASs at that layer.
    Note that this definition implies that the agent cannot
    determine until after a ten second interval has passed whether a
    given one-second interval belongs to available or unavailable
    time.  If the agent chooses to update the various performance
    statistics in real time then it must be prepared to
    retroactively reduce the ES, SES, and SEFS counts by 10 and
    increase the UAS count by 10 when it determines that available
    time has been entered.  It must also be prepared to reduce the
    CV count by the number of violations counted since the onset of
    unavailable time.  The agent must be similarly prepared to
    retroactively decrease the UAS count by 10 and increase the ES
    and CV counts as necessary upon entering available time.  A
    special case exists when the 10 second period leading to
    available or unavailable time crosses a 900 second statistics
    window boundary, as the foregoing description implies that the
    CV, ES, SES, SEFS, and UAS counts the PREVIOUS interval must be
    adjusted.  In this case successive GETs of the affected
    sonetPathIntervalSES and sonetPathIntervalUAS objects (and the
    analogous Line and VT objects also) objects will return
    differing values if the first GET occurs during the first few
    seconds of the window.
    According to ANSI T1.231 unavailable time begins at the _onset_
    of 10 contiguous severely errored seconds -- that is,
    unavailable time starts with the _first_ of the 10 contiguous
    SESs.  Also, while an interface is deemed unavailable all
    counters for that interface are frozen except for the UAS count.
    It follows that an implementation which strictly complies with
    this standard must _not_ increment any counters other than the
    UAS count -- even temporarily -- as a result of anything that
    happens during those 10 seconds.  Since changes in the signal
    state lag the data to which they apply by 10 seconds, an ANSI-
    compliant implementation must pass the one-second statistics
    through a 10-second delay line prior to updating any counters.
    That can be done by performing the following steps at the end of
    each one second interval.

i) Read near/far end CV counter and alarm status flags from the

    hardware.

ii) Accumulate the CV counts for the preceding second and compare

    them to the ES and SES threshold for the layer in question.
    Update the signal state and shift the one-second CV counts and
    ES/SES flags into the 10-element delay line.  Note that far-end
    one-second statistics are to be flagged as "absent" during any
    second in which there is an incoming defect at the layer in
    question or at any lower layer.

iii) Update the current interval statistics using the signal state

    from the _previous_ update cycle and the one-second CV counts
    and ES/SES flags shifted out of the 10-element delay line.
    This approach is further described in Appendix A. An agent may
    choose to use this approach in lieu of retroactive adjustments
    to the counters.
    In any case, a linkDown trap shall be sent only after the agent
    has determined for certain that the unavailable state has been
    entered, but the time on the trap will be that of the first UAS
    (i.e., 10 seconds earlier).  A linkUp trap shall be handled
    similarly.

Unequipped

    If a Path or VT connection is not provisioned (idle) the SONET
    equipment will signal this state by transmitting the Path or VT
    Signal Label as follows:
    - byte C2 of the STS Path Overhead equal to 0 for an unequipped
    Path,
    - byte V5 of the VT Path Overhead equal to 0 for an unequipped
    VT.

Signal Label Mismatch

    A Path or VT connection is not correctly provisioned if a
    received Path or VT Signal Label mismatch occurs.  A received
    Signal Label is considered mismatched if it does not equal
    either the locally provisioned value or the value 'equipped
    non-specific' (1 hex). Note that any received non-zero Signal
    Label is considered a locally provisioned value of 'equipped
    non-specific'.  Only in-service, provisioned Path Terminating
    equipment can detect mismatched Signal labels. It is considered
    provisioned if it has been configured for a mapping and has been
    assigned signals to and from which the mapping takes place.
    While a Path is unequipped or has mismatched signal labels
    ES/SES counts continue, but these conditions do not themselves
    contribute to ES/SES.

Circuit Identifier

    This is a character string specified by the circuit vendor, and
    is useful when communicating with the vendor during the
    troubleshooting process.

Object Definitions

SONET-MIB DEFINITIONS ::= BEGIN

IMPORTS

MODULE-IDENTITY, OBJECT-TYPE,
Integer32, transmission
      FROM SNMPv2-SMI
DisplayString, TruthValue
      FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP
      FROM SNMPv2-CONF
ifIndex
      FROM IF-MIB
PerfCurrentCount, PerfIntervalCount
      FROM PerfHist-TC-MIB;

-- This is the MIB module for the SONET/SDH Interface objects.

sonetMIB MODULE-IDENTITY

LAST-UPDATED "9810190000Z"
ORGANIZATION "IETF AToM MIB Working Group"
CONTACT-INFO
  "Kaj Tesink
   Telcordia Technologies
   Tel: (732) 758-5254
   Fax: (732) 758-2269
   E-mail: [email protected]."
DESCRIPTION
     "The MIB module to describe
     SONET/SDH interfaces objects."
REVISION      "9810190000Z"
DESCRIPTION
    "The key changes made to this MIB module
    since its initial publication in RFC 1595
    are as follows.
    (1) The MODULE-IDENTITY has been updated to reflect the
        changes to the MIB.
    (2) Where applicable, the textual conventions
        PerfCurrentCount and PerfIntervalCount from
        PerfHist-TC-MIB have been used in place of Gauge32.
    (3) An agent now has the option to delay updates to
        the various performance counts in lieu of performing
        retroactive adjustments upon entering into or exiting
        from unavailable time. This implementation option is
        described in Appendix A of this memo.
    (4) In order to make the SONET-MIB more useful for
        circuit provisioning, the formerly read-only objects
        sonetMediumType, sonetMediumLineCoding,
        sonetMediumLineType, and sonetMediumCircuitIdentifier
        have been given a MAX-ACCESS of read-write. The
        MIN-ACCESS remains read-only.
    (5) The DESCRIPTION clause for sonetMediumTimeElapsed has
        been updated to describe its behaviour if the duration
        of the current interval exceeds the maximum value.
    (6) The DESCRIPTION clause for sonetMediumValidIntervals
        has been updated to describe its behaviour when some
        intervals may be unavailable, and the object
        sonetMediumInvalidIntervals has been added to keep
        count of the number of missing intervals (if any).
    (7) The object sonetMediumLoopbackConfig has been added
        to enable or disable loopback configurations.
    (8) Because the error count thresholds for declaring
        severely errored seconds that are specified in ANSI
        T1.231-1993, ITU-T G.826-1995, and ANSI T1.231-1997
        are all different from each other and from the thresholds
        specified in RFC 1595, an enumerated INTEGER object
        sonetSESthresholdSet has been added to allow an agent
        to specify which threshold set is in use. Text has
        been added to Section 3 stating that if this object is
        not implemented the thresholds specified in RFC 1595
        should be assumed, and the table containing those
        thresholds has been moved to Appendix B of this memo.
    (9) A column with SYNTAX TruthValue has been added to each
        interval table.  The purpose of the additional column
        is to indicate, for each interval, whether the data
        is valid in the sense intended by ANSI T1.231 clause
        9.1.2.2 [31][35]. The objects in question are:
            sonetSectionIntervalValidData
            sonetLineIntervalValidData
            sonetFarEndLineIntervalValidData
            sonetPathIntervalValidData
            sonetFarEndPathIntervalValidData
            sonetVTIntervalValidData
            sonetFarEndVTIntervalValidData
   (10) The ranges for sonetPathCurrentStatus and
        sonetVTCurrentStatus have been made consistent
        with the DESCRIPTION clauses.
   (11) The conformance information has been updated. Previous
        conformance information from RFC 1595 has been
        deprecated. Some typographical errors in the deprecated
        section have been corrected in order to prevent
        MIB compilation errors."
REVISION      "9401030000Z"
DESCRIPTION
    "The RFC1595 version of this MIB module."
::= { transmission 39 }

-- This is the MIB module for the SONET/SDH objects

sonetObjects OBJECT IDENTIFIER ::= { sonetMIB 1 }

sonetObjectsPath OBJECT IDENTIFIER ::= { sonetMIB 2 }

sonetObjectsVT OBJECT IDENTIFIER ::= { sonetMIB 3 }

-- groups in the SONET/SDH MIB module

sonetMedium OBJECT IDENTIFIER ::= { sonetObjects 1 }

sonetSection OBJECT IDENTIFIER ::= { sonetObjects 2 }

sonetLine OBJECT IDENTIFIER ::= { sonetObjects 3 }

sonetFarEndLine OBJECT IDENTIFIER ::= { sonetObjects 4 }

sonetPath OBJECT IDENTIFIER ::= { sonetObjectsPath 1 }

sonetFarEndPath OBJECT IDENTIFIER ::= { sonetObjectsPath 2 }

sonetVT OBJECT IDENTIFIER ::= { sonetObjectsVT 1 }

sonetFarEndVT OBJECT IDENTIFIER ::= { sonetObjectsVT 2 }

-- the SONET/SDH Medium group

-- SONET/SDH interfaces for some applications may be electrical -- interfaces and not optical interfaces. This group handles -- the configuration information for both optical SONET/SDH -- interfaces and electrical SONET/SDH interfaces.

sonetMediumTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetMediumEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
   "The SONET/SDH Medium table."
 ::= { sonetMedium 1 }

sonetMediumEntry OBJECT-TYPE

SYNTAX  SonetMediumEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
   "An entry in the SONET/SDH Medium table."
INDEX   { ifIndex }
 ::= { sonetMediumTable 1 }

SonetMediumEntry ::=

SEQUENCE {
     sonetMediumType               INTEGER,
     sonetMediumTimeElapsed        Integer32,
     sonetMediumValidIntervals     Integer32,
     sonetMediumLineCoding         INTEGER,
     sonetMediumLineType           INTEGER,
     sonetMediumCircuitIdentifier  DisplayString,
     sonetMediumInvalidIntervals   Integer32,
     sonetMediumLoopbackConfig     BITS
}

sonetMediumType OBJECT-TYPE

SYNTAX  INTEGER  {
           sonet(1),
           sdh(2)
        }
MAX-ACCESS  read-write
STATUS  current
DESCRIPTION
   "This variable identifies whether a SONET
   or a SDH signal is used across this interface."
::= { sonetMediumEntry 1 }

sonetMediumTimeElapsed OBJECT-TYPE

SYNTAX  Integer32 (1..900)
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "The number of seconds, including partial seconds,
   that have elapsed since the beginning of the current
   measurement period. If, for some reason, such as an
   adjustment in the system's time-of-day clock, the
   current interval exceeds the maximum value, the
   agent will return the maximum value."
::= { sonetMediumEntry 2 }

sonetMediumValidIntervals OBJECT-TYPE

SYNTAX  Integer32 (0..96)
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "The number of previous 15-minute intervals
   for which data was collected.
   A SONET/SDH interface must be capable
   of supporting at least n intervals.
   The minimum value of n is 4.
   The default of n is 32.
   The maximum value of n is 96.
   The value will be <n> unless the measurement was
   (re-)started within the last (<n>*15) minutes, in which
   case the value will be the number of complete 15
   minute intervals for which the agent has at least
   some data. In certain cases (e.g., in the case
   where the agent is a proxy) it is possible that some
   intervals are unavailable.  In this case, this
   interval is the maximum interval number for
   which data is available. "
::= { sonetMediumEntry 3 }

sonetMediumLineCoding OBJECT-TYPE

SYNTAX  INTEGER {
            sonetMediumOther(1),
            sonetMediumB3ZS(2),
            sonetMediumCMI(3),
            sonetMediumNRZ(4),
            sonetMediumRZ(5)
        }
MAX-ACCESS  read-write
STATUS  current
DESCRIPTION
   "This variable describes the line coding for
   this interface. The B3ZS and CMI are used for
   electrical SONET/SDH signals (STS-1 and STS-3).
   The Non-Return to Zero (NRZ) and the Return
   to Zero are used for optical SONET/SDH signals."
::= { sonetMediumEntry 4 }

sonetMediumLineType OBJECT-TYPE

SYNTAX  INTEGER {
            sonetOther(1),
            sonetShortSingleMode(2),
            sonetLongSingleMode(3),
            sonetMultiMode(4),
            sonetCoax(5),
            sonetUTP(6)
        }
MAX-ACCESS  read-write
STATUS  current
DESCRIPTION
   "This variable describes the line type for
   this interface. The line types are
   Short and Long Range
   Single Mode fiber or Multi-Mode fiber interfaces,
   and coax and UTP for electrical interfaces.  The
   value sonetOther should be used when the Line Type is
   not one of the listed values."
::= { sonetMediumEntry 5 }

sonetMediumCircuitIdentifier OBJECT-TYPE

SYNTAX  DisplayString (SIZE (0..255))
MAX-ACCESS  read-write
STATUS  current
DESCRIPTION
   "This variable contains the transmission
   vendor's circuit identifier, for the
   purpose of facilitating troubleshooting.
   Note that the circuit identifier, if available,
   is also represented by ifPhysAddress."
::= { sonetMediumEntry 6 }

sonetMediumInvalidIntervals OBJECT-TYPE

SYNTAX  Integer32 (0..96)
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
    "The number of intervals in the range from
    0 to sonetMediumValidIntervals for which no
    data is available. This object will typically
    be zero except in cases where the data for some
    intervals are not available (e.g., in proxy
    situations)."
::= { sonetMediumEntry 7 }

sonetMediumLoopbackConfig OBJECT-TYPE

SYNTAX      BITS {
              sonetNoLoop(0),
              sonetFacilityLoop(1),
              sonetTerminalLoop(2),
              sonetOtherLoop(3) }
MAX-ACCESS  read-write
STATUS      current
DESCRIPTION
   "The current loopback state of the SONET/SDH interface.  The
    values mean:
      sonetNoLoop
         Not in the loopback state. A device that is not
         capable of performing a loopback on this interface
         shall always return this value.
      sonetFacilityLoop
         The received signal at this interface is looped back
         out through the corresponding transmitter in the return
         direction.
      sonetTerminalLoop
         The signal that is about to be transmitted is connected
         to the associated incoming receiver.
      sonetOtherLoop
         Loopbacks that are not defined here."
::= { sonetMediumEntry 8 }

sonetSESthresholdSet OBJECT-TYPE

SYNTAX   INTEGER {
           other(1),
           Bellcore1991(2),
           ansi1993(3),
           itu1995(4),
           ansi1997(5)
                  }
MAX-ACCESS      read-write
STATUS          current
DESCRIPTION
  "An enumerated integer indicating which
   recognized set of SES thresholds that
   the agent uses for determining severely
   errored seconds and unavailable time.
   other(1)
     None of the following.
   Bellcore1991(2)
     Bellcore TR-NWT-000253, 1991 [32], or
     ANSI T1M1.3/93-005R2, 1993 [22].
     See also Appendix B.
   ansi1993(3)
     ANSI T1.231, 1993 [31], or
     Bellcore GR-253-CORE, Issue 2, 1995 [34]
   itu1995(4)
     ITU Recommendation G.826, 1995 [33]
   ansi1997(5)
     ANSI T1.231, 1997 [35]
   If a manager changes the value of this
   object then the SES statistics collected
   prior to this change must be invalidated."
 ::= { sonetMedium 2 }

-- the SONET/SDH Section group

-- this group consists of 2 tables: -- - the SONET/SDH Section Current Table -- - the SONET/SDH Section Interval Table

-- the SONET/SDH Section Current Table

-- The SONET/SDH Section

-- current table contains various statistics -- being collected for the current 15 minute interval.

sonetSectionCurrentTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetSectionCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
   "The SONET/SDH Section Current table."
 ::= { sonetSection 1 }

sonetSectionCurrentEntry OBJECT-TYPE

SYNTAX  SonetSectionCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
   "An entry in the SONET/SDH Section Current table."
INDEX   { ifIndex }
 ::= { sonetSectionCurrentTable 1 }

SonetSectionCurrentEntry ::=

SEQUENCE {
    sonetSectionCurrentStatus   Integer32,
    sonetSectionCurrentESs      PerfCurrentCount,
    sonetSectionCurrentSESs     PerfCurrentCount,
    sonetSectionCurrentSEFSs    PerfCurrentCount,
    sonetSectionCurrentCVs      PerfCurrentCount
}

sonetSectionCurrentStatus OBJECT-TYPE

SYNTAX  Integer32 (1..6)
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "This variable indicates the
   status of the interface.
   The sonetSectionCurrentStatus
   is a bit map represented
   as a sum, therefore,
   it can represent multiple defects
   simultaneously.
   The sonetSectionNoDefect should be
   set if and only if
   no other flag is set.
   The various bit positions are:
         1   sonetSectionNoDefect
         2   sonetSectionLOS
         4   sonetSectionLOF"
 ::= { sonetSectionCurrentEntry 1 }

sonetSectionCurrentESs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "The counter associated with the number of Errored
   Seconds encountered by a SONET/SDH
   Section in the current 15 minute interval."
 ::= { sonetSectionCurrentEntry 2 }

sonetSectionCurrentSESs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "The counter associated with the number of
   Severely Errored Seconds
   encountered by a SONET/SDH Section in the current 15
   minute interval."
 ::= { sonetSectionCurrentEntry 3 }

sonetSectionCurrentSEFSs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "The counter associated with the number of
   Severely Errored Framing Seconds
   encountered by a SONET/SDH Section in the current
   15 minute interval."
::= { sonetSectionCurrentEntry 4 }

sonetSectionCurrentCVs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "The counter associated with the number of Coding
   Violations encountered by a
   SONET/SDH Section in the current 15 minute interval."
 ::= { sonetSectionCurrentEntry 5 }

-- the SONET/SDH Section Interval Table

-- The SONET/SDH Section Interval Table -- contains various statistics -- collected by each system over a maximum -- of the previous 24 hours of -- operation. The past 24 hours may be broken into 96 -- completed 15 minute intervals. -- A system is required to store at -- least 4 completed 15 minute interval. -- The default value is 32 intervals.

sonetSectionIntervalTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetSectionIntervalEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
   "The SONET/SDH Section Interval table."
 ::= { sonetSection 2 }

sonetSectionIntervalEntry OBJECT-TYPE

SYNTAX  SonetSectionIntervalEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
   "An entry in the SONET/SDH Section Interval table."
INDEX   { ifIndex,
          sonetSectionIntervalNumber }
 ::= { sonetSectionIntervalTable 1 }

SonetSectionIntervalEntry ::=

SEQUENCE {
     sonetSectionIntervalNumber  Integer32,
     sonetSectionIntervalESs     PerfIntervalCount,
     sonetSectionIntervalSESs    PerfIntervalCount,
     sonetSectionIntervalSEFSs   PerfIntervalCount,
     sonetSectionIntervalCVs     PerfIntervalCount,
     sonetSectionIntervalValidData  TruthValue
}

sonetSectionIntervalNumber OBJECT-TYPE

SYNTAX  Integer32 (1..96)
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
  "A number between 1 and 96, which identifies the
  interval for which the set of statistics is available.
  The interval identified by 1 is the most recently
  completed 15 minute interval,
  and the interval identified
  by N is the interval immediately preceding the
  one identified
  by N-1."
 ::= { sonetSectionIntervalEntry 1 }

sonetSectionIntervalESs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "The counter associated with the number of
   Errored Seconds encountered
   by a SONET/SDH Section in a
   particular 15-minute interval
   in the past 24 hours."
 ::= { sonetSectionIntervalEntry 2 }

sonetSectionIntervalSESs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "The counter associated with the number of
   Severely Errored Seconds
   encountered by a SONET/SDH Section in a
   particular 15-minute interval
   in the past 24 hours."
::= { sonetSectionIntervalEntry 3 }

sonetSectionIntervalSEFSs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "The counter associated with the number of
   Severely Errored Framing Seconds
   encountered by a SONET/SDH Section in a
   particular 15-minute interval
   in the past 24 hours."
::= { sonetSectionIntervalEntry 4 }

sonetSectionIntervalCVs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "The counter associated with the number of Coding
   Violations encountered by a
   SONET/SDH Section in a particular 15-minute interval
   in the past 24 hours."
::= { sonetSectionIntervalEntry 5 }

sonetSectionIntervalValidData OBJECT-TYPE

SYNTAX  TruthValue
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "This variable indicates if the data for this
    interval is valid."
::= { sonetSectionIntervalEntry 6 }

-- the SONET/SDH Line group

-- this group consists of 2 tables: -- - the SONET/SDH Line Current Table -- - the SONET/SDH Line Interval Table

-- the SONET/SDH Line Current Table

-- The SONET/SDH Line -- current table contains various statistics -- being collected for the current 15 minute interval.

sonetLineCurrentTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetLineCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
  "The SONET/SDH Line Current table."
::= { sonetLine 1 }

sonetLineCurrentEntry OBJECT-TYPE

SYNTAX  SonetLineCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
  "An entry in the SONET/SDH Line Current table."
INDEX   { ifIndex }
::= { sonetLineCurrentTable 1 }

SonetLineCurrentEntry ::=

SEQUENCE {
     sonetLineCurrentStatus    Integer32,
     sonetLineCurrentESs       PerfCurrentCount,
     sonetLineCurrentSESs      PerfCurrentCount,
     sonetLineCurrentCVs       PerfCurrentCount,
     sonetLineCurrentUASs      PerfCurrentCount
 }

sonetLineCurrentStatus OBJECT-TYPE

SYNTAX  Integer32 (1..6)
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "This variable indicates the
   status of the interface.
   The sonetLineCurrentStatus
   is a bit map represented
   as a sum, therefore,
   it can represent multiple defects
   simultaneously.
   The sonetLineNoDefect should be
   set if and only if
   no other flag is set.
   The various bit positions are:
    1   sonetLineNoDefect
    2   sonetLineAIS
    4   sonetLineRDI"
 ::= { sonetLineCurrentEntry 1 }

sonetLineCurrentESs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of Errored
 Seconds encountered by a SONET/SDH
 Line in the current 15 minute interval."
::= { sonetLineCurrentEntry 2 }

sonetLineCurrentSESs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of
 Severely Errored Seconds
 encountered by a SONET/SDH Line in the current 15
 minute
 interval."
::= { sonetLineCurrentEntry 3 }

sonetLineCurrentCVs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of Coding
 Violations encountered by a
 SONET/SDH Line in the current 15 minute interval."
::= { sonetLineCurrentEntry 4 }

sonetLineCurrentUASs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of
 Unavailable Seconds
 encountered by a SONET/SDH Line in the current 15
 minute
 interval."
::= { sonetLineCurrentEntry 5 }

-- the SONET/SDH Line Interval Table

-- The SONET/SDH Line Interval Table -- contains various statistics -- collected by each system over a maximum -- of the previous 24 hours of -- operation. The past 24 hours may be broken into 96 -- completed 15 minute intervals. -- A system is required to store at -- least 4 completed 15 minute interval. -- The default value is 32 intervals.

sonetLineIntervalTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetLineIntervalEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
   "The SONET/SDH Line Interval table."
 ::= { sonetLine 2 }

sonetLineIntervalEntry OBJECT-TYPE

SYNTAX  SonetLineIntervalEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
   "An entry in the SONET/SDH Line Interval table."

INDEX { ifIndex,

         sonetLineIntervalNumber }
= { sonetLineIntervalTable 1 }

SonetLineIntervalEntry ::=

SEQUENCE {
    sonetLineIntervalNumber    Integer32,
    sonetLineIntervalESs       PerfIntervalCount,
    sonetLineIntervalSESs      PerfIntervalCount,
    sonetLineIntervalCVs       PerfIntervalCount,
    sonetLineIntervalUASs      PerfIntervalCount,
    sonetLineIntervalValidData TruthValue
}

sonetLineIntervalNumber OBJECT-TYPE

SYNTAX  Integer32 (1..96)
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
    "A number between 1 and 96, which identifies the
    interval for which the set of statistics is available.
    The interval identified by 1 is the most recently
    completed 15 minute interval,
    and the interval identified
    by N is the interval immediately preceding the
    one identified
    by N-1."
 ::= { sonetLineIntervalEntry 1 }

sonetLineIntervalESs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "The counter associated with the number of
   Errored Seconds encountered
   by a SONET/SDH Line in a
   particular 15-minute interval
   in the past 24 hours."
 ::= { sonetLineIntervalEntry 2 }

sonetLineIntervalSESs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "The counter associated with the number of
   Severely Errored Seconds
   encountered by a SONET/SDH Line in a
   particular 15-minute interval
   in the past 24 hours."
  ::= { sonetLineIntervalEntry 3 }

sonetLineIntervalCVs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
  "The counter associated with the number of Coding
  Violations encountered by a
  SONET/SDH Line in a
  particular 15-minute interval
  in the past 24 hours."
::= { sonetLineIntervalEntry 4 }

sonetLineIntervalUASs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
  "The counter associated with the
  number of Unavailable Seconds
  encountered by a SONET/SDH Line in
  a particular 15-minute interval
  in the past 24 hours."
::= { sonetLineIntervalEntry 5 }

sonetLineIntervalValidData OBJECT-TYPE

SYNTAX  TruthValue
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "This variable indicates if the data for this
    interval is valid."
::= { sonetLineIntervalEntry 6 }

-- The SONET/SDH Far End Line group. -- This group may only be implemented by SONET/SDH (LTEs) -- systems that provide for a far end block error (FEBE) -- information at the SONET/SDH Line Layer.

-- This group consists of two tables: -- SONET/SDH Far End Line Current Table -- SONET/SDH Far End Line Interval Table

-- The SONET/SDH Far End Line Current Table

-- The SONET/SDH Far End Line Current table contains -- various statistics being -- collected for the current 15 minute interval. -- The statistics are collected from the far end -- block error code (FEBE) -- within the third Z2 byte of the Line Overhead -- in Broadband ISDN applications. -- The definitions are the same as described for -- the near-end information.

sonetFarEndLineCurrentTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetFarEndLineCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
  "The SONET/SDH Far End Line Current table."
::= { sonetFarEndLine 1 }

sonetFarEndLineCurrentEntry OBJECT-TYPE

SYNTAX  SonetFarEndLineCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
  "An entry in the SONET/SDH Far End Line Current table."
INDEX   { ifIndex }
::= { sonetFarEndLineCurrentTable 1 }

SonetFarEndLineCurrentEntry ::=

SEQUENCE {
    sonetFarEndLineCurrentESs       PerfCurrentCount,
    sonetFarEndLineCurrentSESs      PerfCurrentCount,
    sonetFarEndLineCurrentCVs       PerfCurrentCount,
    sonetFarEndLineCurrentUASs      PerfCurrentCount
   }

sonetFarEndLineCurrentESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION

   "The counter associated with the number of Far
   End Errored Seconds encountered by a SONET/SDH
   interface in the current 15 minute interval."
= { sonetFarEndLineCurrentEntry 1 }

sonetFarEndLineCurrentSESs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION

   "The counter associated with the number of
   Far End Severely Errored Seconds
   encountered by a SONET/SDH Medium/Section/Line
   interface in the current 15 minute
   interval."
= { sonetFarEndLineCurrentEntry 2 }

sonetFarEndLineCurrentCVs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION

   "The counter associated with the number of
   Far End Coding Violations reported via
   the far end block error count
   encountered by a
   SONET/SDH Medium/Section/Line
   interface in the current 15 minute interval."
= { sonetFarEndLineCurrentEntry 3 }

sonetFarEndLineCurrentUASs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION

   "The counter associated with the number of
   Far End Unavailable Seconds
   encountered by a
   SONET/SDH Medium/Section/Line
   interface in the current 15 minute interval."
= { sonetFarEndLineCurrentEntry 4 }

-- The SONET/SDH Far End Line Interval Table

-- The SONET/SDH Far End Line Interval Table -- contains various statistics -- collected by each system over a maximum

-- of the previous 24 hours of -- operation. The past 24 hours may be broken into 96 -- completed 15 minute intervals. -- A system is required to store at -- least 4 completed 15 minute interval. -- The default value is 32 intervals.

sonetFarEndLineIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF SonetFarEndLineIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION

  "The SONET/SDH Far End Line Interval table."
= { sonetFarEndLine 2 }

sonetFarEndLineIntervalEntry OBJECT-TYPE SYNTAX SonetFarEndLineIntervalEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION

 "An entry in the SONET/SDH Far
 End Line Interval table."

INDEX { ifIndex,

         sonetFarEndLineIntervalNumber }
= { sonetFarEndLineIntervalTable 1 }

SonetFarEndLineIntervalEntry ::=

SEQUENCE {
     sonetFarEndLineIntervalNumber    Integer32,
     sonetFarEndLineIntervalESs       PerfIntervalCount,
     sonetFarEndLineIntervalSESs      PerfIntervalCount,
     sonetFarEndLineIntervalCVs       PerfIntervalCount,
     sonetFarEndLineIntervalUASs      PerfIntervalCount,
     sonetFarEndLineIntervalValidData TruthValue
}

sonetFarEndLineIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS not-accessible STATUS current DESCRIPTION

     "A number between 1 and 96, which identifies the
     interval for which the set of statistics is available.
     The interval identified by 1 is the most recently
     completed 15 minute interval,
     and the interval identified
     by N is the interval immediately preceding the
     one identified
     by N-1."
= { sonetFarEndLineIntervalEntry 1 }

sonetFarEndLineIntervalESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION

    "The counter associated with the number of
    Far End Errored Seconds encountered
    by a SONET/SDH Line
    interface in a particular 15-minute interval
    in the past 24 hours."
 ::= { sonetFarEndLineIntervalEntry 2 }

sonetFarEndLineIntervalSESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION

    "The counter associated with the number of
    Far End Severely Errored Seconds
    encountered by a SONET/SDH Line
    interface in a particular 15-minute interval
    in the past 24 hours."
 ::= { sonetFarEndLineIntervalEntry 3 }

sonetFarEndLineIntervalCVs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
     "The counter associated with the number of
     Far End Coding Violations reported via
     the far end block error count
     encountered by a
     SONET/SDH Line
     interface in a particular 15-minute interval
     in the past 24 hours."
::= { sonetFarEndLineIntervalEntry 4 }

sonetFarEndLineIntervalUASs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION

   "The counter associated with the number of
   Far End Unavailable Seconds
   encountered by a
   SONET/SDH Line
   interface in a particular 15-minute interval
   in the past 24 hours."
= { sonetFarEndLineIntervalEntry 5 }

sonetFarEndLineIntervalValidData OBJECT-TYPE

SYNTAX  TruthValue
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "This variable indicates if the data for this
    interval is valid."
::= { sonetFarEndLineIntervalEntry 6 }

-- the SONET/SDH Path group

-- this group consists of 2 tables: -- - the SONET/SDH Path Current Table -- - the SONET/SDH Path Interval Table

-- the SONET/SDH Path Current Table

-- The SONET/SDH Path -- current table contains various statistics -- being collected for the current 15 minute interval.

sonetPathCurrentTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetPathCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
 "The SONET/SDH Path Current table."
= { sonetPath 1 }

sonetPathCurrentEntry OBJECT-TYPE

SYNTAX  SonetPathCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
 "An entry in the SONET/SDH Path Current table."
INDEX   { ifIndex }
= { sonetPathCurrentTable 1 }

SonetPathCurrentEntry ::=

SEQUENCE {
    sonetPathCurrentWidth      INTEGER,
    sonetPathCurrentStatus     Integer32,
    sonetPathCurrentESs        PerfCurrentCount,
    sonetPathCurrentSESs       PerfCurrentCount,
    sonetPathCurrentCVs        PerfCurrentCount,
    sonetPathCurrentUASs       PerfCurrentCount
}

sonetPathCurrentWidth OBJECT-TYPE

SYNTAX  INTEGER  {
        sts1(1),
        sts3cSTM1(2),
        sts12cSTM4(3),
        sts24c(4),
        sts48cSTM16(5)
 }
MAX-ACCESS  read-write
STATUS  current
DESCRIPTION
 "A value that indicates the type of the SONET/SDH
 Path.  For SONET, the assigned types are
 the STS-Nc SPEs, where N = 1, 3, 12, 24, and 48.
 STS-1 is equal to 51.84 Mbps.  For SDH, the assigned
 types are the STM-Nc VCs, where N = 1, 4, and 16."
= { sonetPathCurrentEntry 1 }

sonetPathCurrentStatus OBJECT-TYPE

SYNTAX  Integer32 (1..62)
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
  "This variable indicates the
  status of the interface.
  The sonetPathCurrentStatus
  is a bit map represented
  as a sum, therefore,
  it can represent multiple defects
  simultaneously.
  The sonetPathNoDefect should be
  set if and only if
  no other flag is set.
  The various bit positions are:
     1   sonetPathNoDefect
     2   sonetPathSTSLOP
     4   sonetPathSTSAIS
     8   sonetPathSTSRDI
    16   sonetPathUnequipped
    32   sonetPathSignalLabelMismatch"
= { sonetPathCurrentEntry 2 }

sonetPathCurrentESs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of Errored
 Seconds encountered by a SONET/SDH
 Path in the current 15 minute interval."
= { sonetPathCurrentEntry 3 }

sonetPathCurrentSESs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of
 Severely Errored Seconds
 encountered by a SONET/SDH Path in the current 15
 minute
 interval."
= { sonetPathCurrentEntry 4 }

sonetPathCurrentCVs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of Coding
 Violations encountered by a
 SONET/SDH Path in the current 15 minute interval."
= { sonetPathCurrentEntry 5 }

sonetPathCurrentUASs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of
 Unavailable Seconds
 encountered by a Path in the current
 15 minute interval."
= { sonetPathCurrentEntry 6 }

-- the SONET/SDH Path Interval Table

-- The SONET/SDH Path Interval Table -- contains various statistics -- collected by each system over a maximum -- of the previous 24 hours of -- operation. The past 24 hours may be broken into 96 -- completed 15 minute intervals. -- A system is required to store at -- least 4 completed 15 minute interval. -- The default value is 32 intervals.

sonetPathIntervalTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetPathIntervalEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
 "The SONET/SDH Path Interval table."
= { sonetPath 2 }

sonetPathIntervalEntry OBJECT-TYPE

SYNTAX  SonetPathIntervalEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
 "An entry in the SONET/SDH Path Interval table."
INDEX   { ifIndex,
          sonetPathIntervalNumber }
= { sonetPathIntervalTable 1 }

SonetPathIntervalEntry ::=

SEQUENCE {
     sonetPathIntervalNumber     Integer32,
     sonetPathIntervalESs        PerfIntervalCount,
     sonetPathIntervalSESs       PerfIntervalCount,
     sonetPathIntervalCVs        PerfIntervalCount,
     sonetPathIntervalUASs       PerfIntervalCount,
     sonetPathIntervalValidData  TruthValue
}

sonetPathIntervalNumber OBJECT-TYPE

SYNTAX  Integer32 (1..96)
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
   "A number between 1 and 96, which identifies the
   interval for which the set of statistics is available.
   The interval identified by 1 is the most recently
   completed 15 minute interval,
   and the interval identified
   by N is the interval immediately preceding the
   one identified
   by N-1."
= { sonetPathIntervalEntry 1 }

sonetPathIntervalESs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of
 Errored Seconds encountered
 by a SONET/SDH Path in a
 particular 15-minute interval
 in the past 24 hours."
= { sonetPathIntervalEntry 2 }

sonetPathIntervalSESs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of
 Severely Errored Seconds
 encountered by a SONET/SDH Path in
 a particular 15-minute interval
 in the past 24 hours."
= { sonetPathIntervalEntry 3 }

sonetPathIntervalCVs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of Coding
 Violations encountered by a
 SONET/SDH Path in a particular 15-minute interval
 in the past 24 hours."
= { sonetPathIntervalEntry 4 }

sonetPathIntervalUASs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of
 Unavailable Seconds
 encountered by a Path in a
 particular 15-minute interval
 in the past 24 hours."
= { sonetPathIntervalEntry 5 }

sonetPathIntervalValidData OBJECT-TYPE

SYNTAX  TruthValue
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "This variable indicates if the data for this
    interval is valid."
::= { sonetPathIntervalEntry 6 }

-- The SONET/SDH Far End Path group

-- This group consists of two tables: -- - SONET/SDH Far End Path Current Table -- - SONET/SDH Far End Path Interval Table

-- The SONET/SDH Far End Path Current Table

-- The SONET/SDH Far End Path Current table -- contains various statistics -- being collected for the current 15 minute interval. -- The statistics are collected from -- the far end block error code -- (FEBE) within the G1 byte of the Path Overhead. -- The definitions are the same as described for -- the near-end information.

sonetFarEndPathCurrentTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetFarEndPathCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
     "The SONET/SDH Far End Path Current table."
::= { sonetFarEndPath 1 }

sonetFarEndPathCurrentEntry OBJECT-TYPE

SYNTAX  SonetFarEndPathCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
     "An entry in the SONET/SDH Far End Path Current table."
INDEX   { ifIndex }
::= { sonetFarEndPathCurrentTable 1 }

SonetFarEndPathCurrentEntry ::=

SEQUENCE {
    sonetFarEndPathCurrentESs       PerfCurrentCount,
    sonetFarEndPathCurrentSESs      PerfCurrentCount,
    sonetFarEndPathCurrentCVs       PerfCurrentCount,
    sonetFarEndPathCurrentUASs      PerfCurrentCount
}

sonetFarEndPathCurrentESs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
     "The counter associated with the number of Far
     End Errored Seconds encountered by a SONET/SDH
     interface in the current 15 minute interval."
::= { sonetFarEndPathCurrentEntry 1 }

sonetFarEndPathCurrentSESs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
     "The counter associated with the number of
     Far End Severely Errored Seconds
     encountered by a SONET/SDH Path
     interface in the current 15 minute
     interval."
::= { sonetFarEndPathCurrentEntry 2 }

sonetFarEndPathCurrentCVs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
     "The counter associated with the number of
     Far End Coding Violations reported via
     the far end block error count
     encountered by a
     SONET/SDH Path interface in
     the current 15 minute interval."
::= { sonetFarEndPathCurrentEntry 3 }

sonetFarEndPathCurrentUASs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current

DESCRIPTION

   "The counter associated with the number of
   Far End Unavailable Seconds
   encountered by a
   SONET/SDH Path interface in
   the current 15 minute interval."
= { sonetFarEndPathCurrentEntry 4 }

-- The SONET/SDH Far End Path Interval Table

-- The SONET/SDH Far End Path Interval Table -- contains various statistics -- collected by each system over a maximum -- of the previous 24 hours of -- operation. The past 24 hours may be broken into 96 -- completed 15 minute intervals. -- A system is required to store at -- least 4 completed 15 minute interval. -- The default value is 32 intervals.

sonetFarEndPathIntervalTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetFarEndPathIntervalEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
    "The SONET/SDH Far End Path Interval table."
::= { sonetFarEndPath 2 }

sonetFarEndPathIntervalEntry OBJECT-TYPE

SYNTAX  SonetFarEndPathIntervalEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
   "An entry in the SONET/SDH Far
   End Path Interval table."
INDEX   { ifIndex,
          sonetFarEndPathIntervalNumber }
::= { sonetFarEndPathIntervalTable 1 }

SonetFarEndPathIntervalEntry ::=

SEQUENCE {
     sonetFarEndPathIntervalNumber     Integer32,
     sonetFarEndPathIntervalESs        PerfIntervalCount,
     sonetFarEndPathIntervalSESs       PerfIntervalCount,
     sonetFarEndPathIntervalCVs        PerfIntervalCount,
     sonetFarEndPathIntervalUASs       PerfIntervalCount,
     sonetFarEndPathIntervalValidData  TruthValue
}

sonetFarEndPathIntervalNumber OBJECT-TYPE SYNTAX Integer32 (1..96) MAX-ACCESS not-accessible STATUS current DESCRIPTION

    "A number between 1 and 96, which identifies the
    interval for which the set of statistics is available.
    The interval identified by 1 is the most recently
    completed 15 minute interval,
    and the interval identified
    by N is the interval immediately preceding the
    one identified
    by N-1."
= { sonetFarEndPathIntervalEntry 1 }

sonetFarEndPathIntervalESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION

    "The counter associated with the number of
    Far End Errored Seconds encountered
    by a SONET/SDH Path interface in a
    particular 15-minute interval
    in the past 24 hours."
= { sonetFarEndPathIntervalEntry 2 }

sonetFarEndPathIntervalSESs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION

    "The counter associated with the number of
    Far End Severely Errored Seconds
    encountered by a SONET/SDH Path interface
    in a particular 15-minute interval
    in the past 24 hours."
= { sonetFarEndPathIntervalEntry 3 }

sonetFarEndPathIntervalCVs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
     "The counter associated with the number of
     Far End Coding Violations reported via
     the far end block error count
     encountered by a
     SONET/SDH Path interface
     in a particular 15-minute interval
     in the past 24 hours."
::= { sonetFarEndPathIntervalEntry 4 }

sonetFarEndPathIntervalUASs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION

   "The counter associated with the number of
   Far End Unavailable Seconds
   encountered by a
   SONET/SDH Path interface in
   a particular 15-minute interval
   in the past 24 hours."
= { sonetFarEndPathIntervalEntry 5 }

sonetFarEndPathIntervalValidData OBJECT-TYPE

SYNTAX  TruthValue
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "This variable indicates if the data for this
    interval is valid."
::= { sonetFarEndPathIntervalEntry 6 }

-- the SONET/SDH Virtual Tributary group

-- this group consists of 2 tables: -- - the SONET/SDH VT Current Table -- - the SONET/SDH VT Interval Table

-- For SDH signals, virtual tributaries are -- called VCs instead of VTs

-- A VT1.5 = VC11 -- A VT2 = VC12 -- A VT3 = none -- A VT6 = VC3

-- the SONET/SDH VT Current Table

-- The SONET/SDH VT current table -- contains various statistics -- being collected for the -- current 15 minute interval.

sonetVTCurrentTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetVTCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
 "The SONET/SDH VT Current table."
= { sonetVT 1 }

sonetVTCurrentEntry OBJECT-TYPE

SYNTAX  SonetVTCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
 "An entry in the SONET/SDH VT Current table."
INDEX   { ifIndex }
= { sonetVTCurrentTable 1 }

SonetVTCurrentEntry ::=

SEQUENCE {
    sonetVTCurrentWidth      INTEGER,
    sonetVTCurrentStatus     Integer32,
    sonetVTCurrentESs        PerfCurrentCount,
    sonetVTCurrentSESs       PerfCurrentCount,
    sonetVTCurrentCVs        PerfCurrentCount,
    sonetVTCurrentUASs       PerfCurrentCount
}

sonetVTCurrentWidth OBJECT-TYPE

SYNTAX  INTEGER {
        vtWidth15VC11(1),
        vtWidth2VC12(2),
        vtWidth3(3),
        vtWidth6VC2(4),
        vtWidth6c(5)
     }
MAX-ACCESS  read-write
STATUS  current
DESCRIPTION
"A value that indicates the type of the SONET
 VT and SDH VC.  Assigned widths are
 VT1.5/VC11, VT2/VC12, VT3, VT6/VC2, and VT6c."
= { sonetVTCurrentEntry 1 }

sonetVTCurrentStatus OBJECT-TYPE

SYNTAX  Integer32 (1..126)
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
  "This variable indicates the
  status of the interface.
  The sonetVTCurrentStatus
  is a bit map represented
  as a sum, therefore,
  it can represent multiple defects
  and failures
  simultaneously.
  The sonetVTNoDefect should be
  set if and only if
  no other flag is set.
  The various bit positions are:
     1   sonetVTNoDefect
     2   sonetVTLOP
     4   sonetVTPathAIS
     8   sonetVTPathRDI
    16   sonetVTPathRFI
    32   sonetVTUnequipped
    64   sonetVTSignalLabelMismatch"
= { sonetVTCurrentEntry 2 }

sonetVTCurrentESs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of Errored
 Seconds encountered by a SONET/SDH
 VT in the current 15 minute interval."
= { sonetVTCurrentEntry 3 }

sonetVTCurrentSESs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of
 Severely Errored Seconds
 encountered by a SONET/SDH VT in the current 15 minute
 interval."
= { sonetVTCurrentEntry 4 }

sonetVTCurrentCVs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of Coding
 Violations encountered by a
 SONET/SDH VT in the current 15 minute interval."
= { sonetVTCurrentEntry 5 }

sonetVTCurrentUASs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of
 Unavailable Seconds
 encountered by a VT in the current
 15 minute interval."
= { sonetVTCurrentEntry 6 }

-- the SONET/SDH VT Interval Table

-- The SONET/SDH VT Interval Table -- contains various statistics -- collected by each system over a maximum -- of the previous 24 hours of -- operation. The past 24 hours may be broken into 96 -- completed 15 minute intervals. -- A system is required to store at -- least 4 completed 15 minute interval. -- The default value is 32 intervals.

sonetVTIntervalTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetVTIntervalEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
 "The SONET/SDH VT Interval table."
= { sonetVT 2 }

sonetVTIntervalEntry OBJECT-TYPE

SYNTAX  SonetVTIntervalEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
 "An entry in the SONET/SDH VT Interval table."
INDEX   { ifIndex,
          sonetVTIntervalNumber }
= { sonetVTIntervalTable 1 }

SonetVTIntervalEntry ::=

SEQUENCE {
    sonetVTIntervalNumber     Integer32,
    sonetVTIntervalESs        PerfIntervalCount,
    sonetVTIntervalSESs       PerfIntervalCount,
    sonetVTIntervalCVs        PerfIntervalCount,
    sonetVTIntervalUASs       PerfIntervalCount,
    sonetVTIntervalValidData  TruthValue
}

sonetVTIntervalNumber OBJECT-TYPE

SYNTAX  Integer32 (1..96)
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
  "A number between 1 and 96, which identifies the
  interval for which the set of statistics is available.
  The interval identified by 1 is the most recently
  completed 15 minute interval,
  and the interval identified
  by N is the interval immediately preceding the
  one identified
  by N-1."
= { sonetVTIntervalEntry 1 }

sonetVTIntervalESs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of
 Errored Seconds encountered
 by a SONET/SDH VT in a particular 15-minute interval
 in the past 24 hours."
= { sonetVTIntervalEntry 2 }

sonetVTIntervalSESs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of
 Severely Errored Seconds
 encountered by a SONET/SDH VT
 in a particular 15-minute interval
 in the past 24 hours."
= { sonetVTIntervalEntry 3 }

sonetVTIntervalCVs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of Coding
 Violations encountered by a
 SONET/SDH VT in a particular 15-minute interval
 in the past 24 hours."
= { sonetVTIntervalEntry 4 }

sonetVTIntervalUASs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
 "The counter associated with the number of
 Unavailable Seconds
 encountered by a VT in a particular 15-minute interval
 in the past 24 hours."
= { sonetVTIntervalEntry 5 }

sonetVTIntervalValidData OBJECT-TYPE

SYNTAX  TruthValue
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "This variable indicates if the data for this
    interval is valid."
::= { sonetVTIntervalEntry 6 }

-- The SONET/SDH Far End VT group

-- This group consists of two tables: -- SONET/SDH Far End VT Current Table -- SONET/SDH Far End VT Interval Table

-- The SONET/SDH Far End VT Current

-- The SONET/SDH Far End VT Current table -- contains various statistics -- being collected for the current 15 minute interval. -- The statistics are collected from -- the far end block error code -- (FEBE) within the G1 byte of the VT Overhead. -- The definitions are the same as described for -- the near-end information.

sonetFarEndVTCurrentTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetFarEndVTCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
    "The SONET/SDH Far End VT Current table."
::= { sonetFarEndVT 1 }

sonetFarEndVTCurrentEntry OBJECT-TYPE

SYNTAX  SonetFarEndVTCurrentEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
    "An entry in the SONET/SDH Far End VT Current table."
INDEX   { ifIndex }
::= { sonetFarEndVTCurrentTable 1 }

SonetFarEndVTCurrentEntry ::=

SEQUENCE {
    sonetFarEndVTCurrentESs       PerfCurrentCount,
    sonetFarEndVTCurrentSESs      PerfCurrentCount,
    sonetFarEndVTCurrentCVs       PerfCurrentCount,
    sonetFarEndVTCurrentUASs      PerfCurrentCount
}

sonetFarEndVTCurrentESs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
    "The counter associated with the number of Far
    End Errored Seconds encountered by a SONET/SDH
    interface in the current 15 minute interval."
= { sonetFarEndVTCurrentEntry 1 }

sonetFarEndVTCurrentSESs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
    "The counter associated with the number of
    Far End Severely Errored Seconds
    encountered by a SONET/SDH VT interface
    in the current 15 minute
    interval."
::= { sonetFarEndVTCurrentEntry 2 }

sonetFarEndVTCurrentCVs OBJECT-TYPE

SYNTAX  PerfCurrentCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
    "The counter associated with the number of
    Far End Coding Violations reported via
    the far end block error count
    encountered by a
    SONET/SDH VT interface
    in the current 15 minute interval."
::= { sonetFarEndVTCurrentEntry 3 }

sonetFarEndVTCurrentUASs OBJECT-TYPE SYNTAX PerfCurrentCount MAX-ACCESS read-only STATUS current DESCRIPTION

  "The counter associated with the number of
  Far End Unavailable Seconds
  encountered by a
  SONET/SDH VT interface
  in the current 15 minute interval."
= { sonetFarEndVTCurrentEntry 4 }

-- The SONET/SDH Far End VT Interval Table

-- The SONET/SDH Far End VT Interval Table -- contains various statistics -- collected by each system over a maximum -- of the previous 24 hours of -- operation. The past 24 hours may be broken into 96 -- completed 15 minute intervals. -- A system is required to store at -- least 4 completed 15 minute interval. -- The default value is 32 intervals.

sonetFarEndVTIntervalTable OBJECT-TYPE

SYNTAX  SEQUENCE OF SonetFarEndVTIntervalEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
   "The SONET/SDH Far End VT Interval table."
::= { sonetFarEndVT 2 }

sonetFarEndVTIntervalEntry OBJECT-TYPE

SYNTAX  SonetFarEndVTIntervalEntry
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
  "An entry in the SONET/SDH Far
  End VT Interval table."
INDEX   { ifIndex,
          sonetFarEndVTIntervalNumber }
::= { sonetFarEndVTIntervalTable 1 }

SonetFarEndVTIntervalEntry ::= SEQUENCE {

     sonetFarEndVTIntervalNumber     Integer32,
     sonetFarEndVTIntervalESs        PerfIntervalCount,
     sonetFarEndVTIntervalSESs       PerfIntervalCount,
     sonetFarEndVTIntervalCVs        PerfIntervalCount,
     sonetFarEndVTIntervalUASs       PerfIntervalCount,
     sonetFarEndVTIntervalValidData  TruthValue
}

sonetFarEndVTIntervalNumber OBJECT-TYPE

SYNTAX  Integer32 (1..96)
MAX-ACCESS  not-accessible
STATUS  current
DESCRIPTION
   "A number between 1 and 96, which identifies the
   interval for which the set of statistics is available.
   The interval identified by 1 is the most recently
   completed 15 minute interval,
   and the interval identified
   by N is the interval immediately preceding the
   one identified
   by N-1."
::= { sonetFarEndVTIntervalEntry 1 }

sonetFarEndVTIntervalESs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
      "The counter associated with the number of
      Far End Errored Seconds encountered
      by a SONET/SDH VT interface
      in a particular 15-minute interval
      in the past 24 hours."
= { sonetFarEndVTIntervalEntry 2 }

sonetFarEndVTIntervalSESs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
      "The counter associated with the number of
      Far End Severely Errored Seconds
      encountered by a SONET/SDH VT interface
      in a particular 15-minute interval
      in the past 24 hours."
::= { sonetFarEndVTIntervalEntry 3 }

sonetFarEndVTIntervalCVs OBJECT-TYPE

SYNTAX  PerfIntervalCount
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
     "The counter associated with the number of
     Far End Coding Violations reported via
     the far end block error count
     encountered by a
     SONET/SDH VT interface in a
     particular 15-minute interval
     in the past 24 hours."
::= { sonetFarEndVTIntervalEntry 4 }

sonetFarEndVTIntervalUASs OBJECT-TYPE SYNTAX PerfIntervalCount MAX-ACCESS read-only STATUS current DESCRIPTION

   "The counter associated with the number of
   Far End Unavailable Seconds
   encountered by a
   SONET/SDH VT interface in a
   particular 15-minute interval
   in the past 24 hours."
= { sonetFarEndVTIntervalEntry 5 }

sonetFarEndVTIntervalValidData OBJECT-TYPE

SYNTAX  TruthValue
MAX-ACCESS  read-only
STATUS  current
DESCRIPTION
   "This variable indicates if the data for this
    interval is valid."
::= { sonetFarEndVTIntervalEntry 6 }

-- conformance information

sonetConformance OBJECT IDENTIFIER ::= { sonetMIB 4 }

sonetGroups OBJECT IDENTIFIER ::= { sonetConformance 1 } sonetCompliances OBJECT IDENTIFIER ::= { sonetConformance 2 }

-- deprecated compliance statement

sonetCompliance MODULE-COMPLIANCE

STATUS  deprecated
DESCRIPTION
        "The compliance statement for SONET/SDH interfaces."
MODULE  -- this module
    MANDATORY-GROUPS { sonetMediumStuff, sonetSectionStuff }
    GROUP       sonetLineStuff
    DESCRIPTION
        "Implementation of this group is mandatory for all
         SONET/SDH systems that terminate SONET/SDH Lines,
         Paths or Virtual Tributaries."
    GROUP       sonetFarEndLineStuff
    DESCRIPTION
        "Implementation of this group is optional for all
         SONET/SDH systems that terminate SONET/SDH Lines,
         Paths or Virtual Tributaries, and that
         provide for a far end block error (FEBE)
         information at the SONET/SDH Line Layer."
    GROUP       sonetPathStuff
    DESCRIPTION
        "Implementation of this group is mandatory for all
         SONET/SDH systems that terminate SONET/SDH
         Paths or Virtual Tributaries."
    OBJECT      sonetPathCurrentWidth
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    GROUP       sonetFarEndPathStuff
    DESCRIPTION
        "Implementation of this group is optional for all
         SONET/SDH systems that terminate SONET/SDH
         Paths or Virtual Tributaries, and that process
         Far End information."
    GROUP       sonetVTStuff
    DESCRIPTION
        "Implementation of this group is mandatory for all
         SONET/SDH systems that terminate SONET/SDH Virtual
         Tributaries."
    OBJECT      sonetVTCurrentWidth
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    GROUP       sonetFarEndVTStuff
    DESCRIPTION
        "Implementation of this group is optional for all
         SONET/SDH systems that terminate the SONET/SDH
         floating Virtual Tributaries, and that process
         Far End information."
::= { sonetCompliances 1 }

-- current compliance statements

sonetCompliance2 MODULE-COMPLIANCE

STATUS  current
DESCRIPTION
        "The compliance statement for SONET/SDH interfaces."
MODULE  -- this module
    MANDATORY-GROUPS { sonetMediumStuff2, sonetSectionStuff2 }
    OBJECT      sonetMediumType
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT      sonetMediumLineCoding
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT      sonetMediumLineType
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT      sonetMediumCircuitIdentifier
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT      sonetMediumLoopbackConfig
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT      sonetSESthresholdSet
    MIN-ACCESS  read-only
    DESCRIPTION
      "Write access is not required, and only one
      of the enumerated values need be supported."
    GROUP       sonetLineStuff2
    DESCRIPTION
        "Implementation of this group is mandatory for all
         SONET/SDH systems that terminate SONET/SDH Lines,
         Paths or Virtual Tributaries."
    GROUP       sonetFarEndLineStuff2
    DESCRIPTION
        "Implementation of this group is optional for all
         SONET/SDH systems that terminate SONET/SDH Lines,
         Paths or Virtual Tributaries, and that
         provide for a far end block error (FEBE)
         information at the SONET/SDH Line Layer."
    GROUP       sonetPathStuff2
    DESCRIPTION
        "Implementation of this group is mandatory for all
         SONET/SDH systems that terminate SONET/SDH
         Paths or Virtual Tributaries."
    OBJECT      sonetPathCurrentWidth
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    GROUP       sonetFarEndPathStuff2
    DESCRIPTION
        "Implementation of this group is optional for all
         SONET/SDH systems that terminate SONET/SDH
         Paths or Virtual Tributaries, and that process
         Far End information."
    GROUP       sonetVTStuff2
    DESCRIPTION
        "Implementation of this group is mandatory for all
         SONET/SDH systems that terminate SONET/SDH Virtual
         Tributaries."
    OBJECT      sonetVTCurrentWidth
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    GROUP       sonetFarEndVTStuff2
    DESCRIPTION
        "Implementation of this group is optional for all
         SONET/SDH systems that terminate the SONET/SDH
         floating Virtual Tributaries, and that process
         Far End information."
::= { sonetCompliances 2 }

-- units of conformance

-- deprecated groups

sonetMediumStuff OBJECT-GROUP

OBJECTS { sonetMediumType,
          sonetMediumTimeElapsed,
          sonetMediumValidIntervals,
          sonetMediumLineCoding,
          sonetMediumLineType,
          sonetMediumCircuitIdentifier }
STATUS  deprecated
DESCRIPTION
        "A collection of objects providing configuration
        information applicable to all SONET/SDH interfaces."
::= { sonetGroups 1 }

sonetSectionStuff OBJECT-GROUP

OBJECTS { sonetSectionCurrentStatus,
          sonetSectionCurrentESs,
          sonetSectionCurrentSESs,
          sonetSectionCurrentSEFSs,
          sonetSectionCurrentCVs,
          sonetSectionIntervalESs,
          sonetSectionIntervalSESs,
          sonetSectionIntervalSEFSs,
          sonetSectionIntervalCVs
}
STATUS  deprecated
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH Section interfaces."
::= { sonetGroups 2 }

sonetLineStuff OBJECT-GROUP

OBJECTS { sonetLineCurrentStatus,
          sonetLineCurrentESs,
          sonetLineCurrentSESs,
          sonetLineCurrentCVs,
          sonetLineCurrentUASs,
          sonetLineIntervalESs,
          sonetLineIntervalSESs,
          sonetLineIntervalCVs,
          sonetLineIntervalUASs }
STATUS  deprecated
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH Line interfaces."
::= { sonetGroups 3 }

sonetFarEndLineStuff OBJECT-GROUP

OBJECTS { sonetFarEndLineCurrentESs,
          sonetFarEndLineCurrentSESs,
          sonetFarEndLineCurrentCVs,
          sonetFarEndLineCurrentUASs,
          sonetFarEndLineIntervalESs,
          sonetFarEndLineIntervalSESs,
          sonetFarEndLineIntervalCVs,
          sonetFarEndLineIntervalUASs }
STATUS  deprecated
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH Line interfaces,
        and maintaining Line Far End information."
::= { sonetGroups 4 }

sonetPathStuff OBJECT-GROUP

OBJECTS { sonetPathCurrentWidth,
          sonetPathCurrentStatus,
          sonetPathCurrentESs,
          sonetPathCurrentSESs,
          sonetPathCurrentCVs,
          sonetPathCurrentUASs,
          sonetPathIntervalESs,
          sonetPathIntervalSESs,
          sonetPathIntervalCVs,
          sonetPathIntervalUASs }
STATUS  deprecated
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH Path interfaces."
::= { sonetGroups 5 }

sonetFarEndPathStuff OBJECT-GROUP

OBJECTS { sonetFarEndPathCurrentESs,
          sonetFarEndPathCurrentSESs,
          sonetFarEndPathCurrentCVs,
          sonetFarEndPathCurrentUASs,
          sonetFarEndPathIntervalESs,
          sonetFarEndPathIntervalSESs,
          sonetFarEndPathIntervalCVs,
          sonetFarEndPathIntervalUASs }
STATUS  deprecated
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH Path interfaces,
        and maintaining Path Far End information."
::= { sonetGroups 6 }

sonetVTStuff OBJECT-GROUP

OBJECTS { sonetVTCurrentWidth,
          sonetVTCurrentStatus,
          sonetVTCurrentESs,
          sonetVTCurrentSESs,
          sonetVTCurrentCVs,
          sonetVTCurrentUASs,
          sonetVTIntervalESs,
          sonetVTIntervalSESs,
          sonetVTIntervalCVs,
          sonetVTIntervalUASs }
STATUS  deprecated
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH VT interfaces."
::= { sonetGroups 7 }

sonetFarEndVTStuff OBJECT-GROUP

OBJECTS { sonetFarEndVTCurrentESs,
          sonetFarEndVTCurrentSESs,
          sonetFarEndVTCurrentCVs,
          sonetFarEndVTCurrentUASs,
          sonetFarEndVTIntervalESs,
          sonetFarEndVTIntervalSESs,
          sonetFarEndVTIntervalCVs,
          sonetFarEndVTIntervalUASs }
STATUS  deprecated
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH VT interfaces,
        and maintaining VT Far End information."
::= { sonetGroups 8 }

-- current groups

sonetMediumStuff2 OBJECT-GROUP

OBJECTS { sonetMediumType,
          sonetMediumTimeElapsed,
          sonetMediumValidIntervals,
          sonetMediumLineCoding,
          sonetMediumLineType,
          sonetMediumCircuitIdentifier,
          sonetMediumInvalidIntervals,
          sonetMediumLoopbackConfig,
          sonetSESthresholdSet }
STATUS  current
DESCRIPTION
        "A collection of objects providing configuration
        information applicable to all SONET/SDH interfaces."
::= { sonetGroups 9 }

sonetSectionStuff2 OBJECT-GROUP

OBJECTS { sonetSectionCurrentStatus,
          sonetSectionCurrentESs,
          sonetSectionCurrentSESs,
          sonetSectionCurrentSEFSs,
          sonetSectionCurrentCVs,
          sonetSectionIntervalESs,
          sonetSectionIntervalSESs,
          sonetSectionIntervalSEFSs,
          sonetSectionIntervalCVs,
          sonetSectionIntervalValidData }
STATUS  current
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH Section interfaces."
::= { sonetGroups 10 }

sonetLineStuff2 OBJECT-GROUP

OBJECTS { sonetLineCurrentStatus,
          sonetLineCurrentESs,
          sonetLineCurrentSESs,
          sonetLineCurrentCVs,
          sonetLineCurrentUASs,
          sonetLineIntervalESs,
          sonetLineIntervalSESs,
          sonetLineIntervalCVs,
          sonetLineIntervalUASs,
          sonetLineIntervalValidData }
STATUS  current
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH Line interfaces."
::= { sonetGroups 11 }

sonetPathStuff2 OBJECT-GROUP

OBJECTS { sonetPathCurrentWidth,
          sonetPathCurrentStatus,
          sonetPathCurrentESs,
          sonetPathCurrentSESs,
          sonetPathCurrentCVs,
          sonetPathCurrentUASs,
          sonetPathIntervalESs,
          sonetPathIntervalSESs,
          sonetPathIntervalCVs,
          sonetPathIntervalUASs,
          sonetPathIntervalValidData }
STATUS  current
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH Path interfaces."
::= { sonetGroups 12 }

sonetVTStuff2 OBJECT-GROUP

OBJECTS { sonetVTCurrentWidth,
          sonetVTCurrentStatus,
          sonetVTCurrentESs,
          sonetVTCurrentSESs,
          sonetVTCurrentCVs,
          sonetVTCurrentUASs,
          sonetVTIntervalESs,
          sonetVTIntervalSESs,
          sonetVTIntervalCVs,
          sonetVTIntervalUASs,
          sonetVTIntervalValidData }
STATUS  current
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH VT interfaces."
::= { sonetGroups 13 }

sonetFarEndLineStuff2 OBJECT-GROUP

OBJECTS { sonetFarEndLineCurrentESs,
          sonetFarEndLineCurrentSESs,
          sonetFarEndLineCurrentCVs,
          sonetFarEndLineCurrentUASs,
          sonetFarEndLineIntervalESs,
          sonetFarEndLineIntervalSESs,
          sonetFarEndLineIntervalCVs,
          sonetFarEndLineIntervalUASs,
          sonetFarEndLineIntervalValidData }
STATUS  current
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH Line interfaces,
        and maintaining Line Far End information."
::= { sonetGroups 14 }

sonetFarEndPathStuff2 OBJECT-GROUP

OBJECTS { sonetFarEndPathCurrentESs,
          sonetFarEndPathCurrentSESs,
          sonetFarEndPathCurrentCVs,
          sonetFarEndPathCurrentUASs,
          sonetFarEndPathIntervalESs,
          sonetFarEndPathIntervalSESs,
          sonetFarEndPathIntervalCVs,
          sonetFarEndPathIntervalUASs,
          sonetFarEndPathIntervalValidData }
STATUS  current
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH Path interfaces,
        and maintaining Path Far End information."
::= { sonetGroups 15 }

sonetFarEndVTStuff2 OBJECT-GROUP

OBJECTS { sonetFarEndVTCurrentESs,
          sonetFarEndVTCurrentSESs,
          sonetFarEndVTCurrentCVs,
          sonetFarEndVTCurrentUASs,
          sonetFarEndVTIntervalESs,
          sonetFarEndVTIntervalSESs,
          sonetFarEndVTIntervalCVs,
          sonetFarEndVTIntervalUASs,
          sonetFarEndVTIntervalValidData }
STATUS  current
DESCRIPTION
        "A collection of objects providing information
        specific to SONET/SDH VT interfaces,
        and maintaining VT Far End information."
::= { sonetGroups 16 }

END

Acknowledgments

This specification is a product of the AToM MIB Working Group. The author would like to acknowledge Mike Heard for his many valuable contributions to this memo.

Security Considerations

There are a number of management objects defined in this MIB that have a MAX-ACCESS clause of read-write and/or read-create. Such objects may be considered sensitive or vulnerable in some network environments. The support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations.

The managed objects in this MIB contain sensitive information since, collectively, they allow influencing of interfaces in SONET/SDH equipment or networks and provide information of their configuration.

It is thus important to control even GET access to these objects and possibly to even encrypt the values of these object when sending them over the network via SNMP. Not all versions of SNMP provide features for such a secure environment.

SNMPv1 by itself is not a secure environment. Even if the network itself is secure (for example by using IPSec), even then, there is no control as to who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB.

It is recommended that the implementers consider the security features as provided by the SNMPv3 framework. Specifically, the use of the User-based Security Model RFC 2274 [12] and the View-based Access Control Model RFC 2275 [15] is recommended.

It is then a customer/user responsibility to ensure that the SNMP entity giving access to an instance of this MIB, is properly configured to give access to the objects only to those principals (users) that have legitimate rights to indeed GET or SET (change/create/delete) them.

References

[1] Harrington, D., Presuhn, R. and B. Wijnen, "An tecture for

    Describing SNMP Management Frameworks", RFC 2271, January 1998.

[2] Rose, M. and K. McCloghrie, "Structure and Identification of

    Management Information for TCP/IP-based Internets", STD 16, RFC
    1155, May 1990.

[3] Rose, M. and K. McCloghrie, "Concise MIB Definitions", STD 16,

    RFC 1212, March 1991.

[4] Rose, M., "A Convention for Defining Traps for use with the

    SNMP", RFC 1215, March 1991

[5] SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M. and S.

    Waldbusser, "Structure of Management Information for Version 2
    of the Simple Network Management Protocol (SNMPv2)", RFC 1902,
    January 1996.

[6] SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M. and S.

    Waldbusser, "Textual Conventions for Version 2 of the Simple
    Network Management Protocol (SNMPv2)", RFC 1903, January 1996.

[7] SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M. and S.

    Waldbusser, "Conformance Statements for Version 2 of the Simple
    Network Management Protocol (SNMPv2)", RFC 1904, January 1996.

[8] Case, J., Fedor, M., Schoffstall, M. and J. Davin, "Simple

    Network Management Protocol", STD 15, RFC 1157, May 1990.

[9] SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M. and S.

    Waldbusser, "Introduction to Community-based SNMPv2", RFC 1901,
    January 1996.

[10] SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M. and S.

    Waldbusser, "Transport Mappings for Version 2 of the Simple
    Network Management Protocol (SNMPv2)", RFC 1906, January 1996.

[11] Case, J., Harrington D., Presuhn R. and B. Wijnen, "Message

    Processing and Dispatching for the Simple Network Management
    Protocol (SNMP)", RFC 2272, January 1998.

[12] Blumenthal, U. and B. Wijnen, "User-based Security Model (USM)

    for version 3 of the Simple Network Management Protocol
    (SNMPv3)", RFC 2274, January 1998.

[13] SNMPv2 Working Group, Case, J., McCloghrie, K., Rose, M. and S.

    Waldbusser, "Protocol Operations for Version 2 of the Simple
    Network Management Protocol (SNMPv2)", RFC 1905, January 1996.

[14] Levi, D., Meyer, P. and B. Stewart, SNMPv3 Applications", RFC

    2273, January 1998.

[15] Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based Access

    Control Model (VACM) for the Simple Network Management Protocol
    (SNMP)", RFC 2275, January 1998.

[16] McCloghrie, K. and M. Rose, "Management Information Base for

    Network Management of TCP/IP-based internets - MIB-II", STD 17,
    RFC 1213, March 1991.

[17] Information processing systems - Open Systems Interconnection -

    Specification of Abstract Syntax Notation One (ASN.1),
    International Organization for Standardization.  International
    Standard 8824, (December, 1987).

[18] Information processing systems - Open Systems Interconnection -

    Specification of Basic Encoding Rules for Abstract Notation One
    (ASN.1), International Organization for Standardization.
    International Standard 8825, (December, 1987).

[19] American National Standard for Telecommunications - Digital

    Hierarchy - Optical Interface Rates and Formats Specification,
    ANSI T1.105-1988.

[20] American National Standard for Telecommunications - Digital

    Hierarchy - Optical Interface Rates and Formats Specification,
    ANSI T1.105-1991.

[21] American National Standard for Telecommunications - Digital

    Hierarchy - Optical Interface Specification (Single-Mode), ANSI
    T1.106-1988.

[22] Draft American National Standard for Telecommunications -

    Digital Hierarchy - Layer 1 In-Service Digital Transmission
    Performance Monitoring, T1M1.3/93-005R2, July 1993.

[23] McCloghrie, K. and F. Kastenholz, "The Interfaces Group MIB",

    RFC 2233, November 1997.

[24] Fowler, D., "Definitions of Managed Objects for the DS3/E3

    Interface Type", RFC 2496, January 1999.

[25] Fowler, D., "Definitions of Managed Objects for the DS1, E1, DS2

    and E2 Interface Types", RFC 2495, January 1999.

[26] CCITT Recommendation G.707, "Synchronous Digital Hierarchy Bit

    Rates", June 1992.

[27] CCITT Recommendation G.708, "Network Node Interface for the

    Synchronous Digital Hierarchy", June 1992.

[28] CCITT Recommendation G.709, "Synchronous Multiplexing

    Structure", June 1992.

[29] CCITT Recommendation G.783, "Characteristics of Synchronous

    Digital Hierarchy (SDH) Multiplexing Equipment Functional
    Blocks", November 1992.

[30] Brown, T. and K. Tesink, "Definitions of Managed Objects for the

    SONET/SDH Interface Type", RFC 1595, March 1994.

[31] American National Standard for Telecommunications - Digital

    Hierarchy - Layer 1 In-Service Digital Transmission Performance
    Monitoring, ANSI T1.231-1993, September 1993.

[32] Bellcore TR-NWT-000253, Issue 1, "Synchronous Optical Network

    (SONET) Transport Systems:  Common Generic Criteria", December
    1991.

[33] ITU Recommendation G.826, "Error Performance Parameters and

    Objectives for International Constant Bit Rate Digital Paths at
    or above Primary Rate", September 1995 (COM 13-R57E).

[34] Bellcore GR-253-CORE, Issue 2, "Synchronous Optical Network

    (SONET) Transport Systems Common Generic Criteria", December
    1995.

[35] American National Standard for Telecommunications - Digital

    Hierarchy - Layer 1 In-Service Digital Transmission Performance
    Monitoring, ANSI T1.231-1997, September 1997.

[36] Tesink, K., " Textual Conventions for MIB Modules Using

    Performance History Based on 15 Minute Intervals", RFC 2493,
    January 1999.

Author's Address

Kaj Tesink Telcordia Technologies 331 Newman Springs Road P.O. Box 7020 Red Bank, NJ 07701-7020

Phone: (732) 758-5254 EMail: [email protected]

Intellectual Property

The IETF takes no position regarding the validity or scope of any intellectual property or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; neither does it represent that it has made any effort to identify any such rights. Information on the IETF's procedures with respect to rights in standards-track and standards-related documentation can be found in BCP-11. Copies of claims of rights made available for publication and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementors or users of this specification can be obtained from the IETF Secretariat.

The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights which may cover technology that may be required to practice this standard. Please address the information to the IETF Executive Director.

Appendix A: The delay-line approach to statistics collection.

According to ANSI T1.231 unavailable time begins at the onset of 10 contiguous severely errored seconds -- that is, unavailable time starts with the first of the 10 contiguous SESs -- and while an interface is deemed unavailable all counters for that interface are frozen except for the UAS count. Since changes in the signal state lag the data to which they apply by 10 seconds, an implementation which wishes to avoid making retroactive adjustments to the counts must pass the the one-second statistics through a 10-second delay line prior to updating any counters. That can be done by performing the following steps at the end of each one second interval.

i) Read near/far end line and path CV counts and alarm status flags

    from the hardware.

ii) Accumulate the CV counts for the preceding second and compare

    them to the ES and SES threshold for the layer in question.
    Update the signal state and shift the one-second CV counts and
    ES/SES flags into the 10-element delay line.  Note that far-end
    one-second statistics are to be flagged as "absent" during any
    second in which there is an incoming defect at the layer in
    question or at any lower layer.

iii) Update the current interval statistics using the signal state

    from the previous update cycle and the one-second CV counts and
    ES/SES flags shifted out of the 10-element delay line.

This procedure guarantees that the statistical counters will be correctly updated at all times, although they lag real time by 10 seconds. It is illustrated in the figure below. At the end of each 15 minutes interval the current interval counts are transferred to the most recent interval entry and each interval is shifted up by one position, with the oldest being discarded if necessary in order to make room. The current interval counts then start over from zero. Note, however, that the signal state calculation does not start anew at each interval boundary; rather, signal state information is retained across interval boundaries.

+--------------------------------------------------------------+ | READ COUNTERS & STATUS INFO FROM HARDWARE | | | |LOS OOF/ SECT LINE LINE LINE LINE PATH PATH PATH PATH PATH | | LOF CV AIS CV RDI FEBE AIS LOP CV RDI CV | +--------------------------------------------------------------+

 |   |     |     |    |    |   |      |    |    |    |    |
 |   |     |     |    |    |   |      |    |    |    |    |
 V   V     V     V    V    V   V      V    V    V    V    V

+--------------------------------------------------------------+ | ACCUM ONE-SEC STATS, CHK ERR THRESHOLDS, & UPDT SIGNAL STATE | | | | | | NEAR END/FAR END NEAR END/FAR END | |SECT SECT SECT LINE LINE LINE LINE PATH PATH PATH PATH | |CV ES SES CV ES SES AVA/UNA CV ES SES AVA/UNA | +--------------------------------------------------------------+

 |    |    |      |    |    |     |      |    |    |     |
 |    |    |      |    |    |     |      |    |    |     |
 V    V    V      V    V    V     |      V    V    V     |

+-------------+ +-------------+ | +-------------+ | |ONE-SEC DELAY| |ONE-SEC DELAY| | |ONE-SEC DELAY| | | (1 OF 10) | | (1 OF 10) | | | (1 OF 10) | | |CV ES SES| |CV ES SES| | |CV ES SES| | +-------------+ +-------------+ | +-------------+ |

 |    |    |      |    |    |     |      |    |    |     |
 /    /    /      /    /    /     /      /    /    /     /
 /    /    /      /    /    /     /      /    /    /     /
 |    |    |      |    |    |     |      |    |    |     |
 V    V    V      V    V    V     |      V    V    V     |

+-------------+ +-------------+ | +-------------+ | |ONE-SEC DELAY| |ONE-SEC DELAY| | |ONE-SEC DELAY| | | (10 OF 10) | | (10 OF 10) | | | (10 OF 10) | | |CV ES SES| |CV ES SES| | |CV ES SES| | +-------------+ +-------------+ | +-------------+ |

 |    |    |      |    |    |     |      |    |    |     |
 |    |    |      |    |    |     |      |    |    |     |
 V    V    V      V    V    V     V      V    V    V     V

+--------------------------------------------------------------+ | UPDATE STATISTICS COUNTERS | | | | NEAR END/FAR END NEAR END/FAR END | | SECTION LINE PATH | | CV ES EFS SES CV ES EFS SES AS UAS CV ES EFS SES AS UAS | +--------------------------------------------------------------+

Note that if such a procedure is adopted there is no current interval data for the first ten seconds after a system comes up. noSuchInstance must be returned if a management station attempts to access the current interval counters during this time.

It is an implementation-specific matter whether an agent assumes that the initial state of the interface is available or unavailable.

Appendix B - RFC1595 SES interpretation

This appendix contains the values for x for the Section, Line, Path, and VT Layers as used in [22][30][32].

              Value for x for SONET/SDH Section SES Definition
         Rate            x               Minimum Bit Error Rate
         =======================================================
         OC-1             9                      1.5 x 10^-7
         OC-3            16                        1 x 10^-7
         OC-9            47                        1 x 10^-7
         OC-12           63                        1 x 10^-7
         OC-18           94                        1 x 10^-7
         OC-24          125                        1 x 10^-7
         OC-36          187                        1 x 10^-7
         OC-48          249                        1 x 10^-7
              Value for x for SONET/SDH Line SES Definition
         Rate            x               Minimum Bit Error Rate
         =======================================================
         OC-1            12                       2 x 10^-7
         OC-3            32                       2 x 10^-7
         OC-9            47                       2 x 10^-7
         OC-12          124                       2 x 10^-7
         OC-18          186                       2 x 10^-7
         OC-24          248                       2 x 10^-7
         OC-36          370                       2 x 10^-7
         OC-48          494                       2 x 10^-7
              Value for x for SONET/SDH STS-Path SES Definition
         Rate            x               Minimum Bit Error Rate
         =======================================================
         STS-1            9                       1.5 x 10^-7
         STS-3           16                         1 x 10^-7
              Value for x for SONET/SDH VT-Path SES Definition
         Rate            x               Minimum Bit Error Rate
         =======================================================
         VT1.5            4                       2 x 10^-6
         VT2              6                       2 x 10^-6
         VT3              8                       2 x 10^-6
         VT6             14                       2 x 10^-6

Full Copyright Statement

Copyright (C) The Internet Society (1999). All Rights Reserved.

This document and translations of it may be copied and furnished to others, and derivative works that comment on or otherwise explain it or assist in its implementation may be prepared, copied, published and distributed, in whole or in part, without restriction of any kind, provided that the above copyright notice and this paragraph are included on all such copies and derivative works. However, this document itself may not be modified in any way, such as by removing the copyright notice or references to the Internet Society or other Internet organizations, except as needed for the purpose of developing Internet standards in which case the procedures for copyrights defined in the Internet Standards process must be followed, or as required to translate it into languages other than English.

The limited permissions granted above are perpetual and will not be revoked by the Internet Society or its successors or assigns.

This document and the information contained herein is provided on an "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.