RFC3498

From RFC-Wiki

Network Working Group J. Kuhfeld Request for Comments: 3498 J. Johnson Category:Standards Track M. Thatcher

                                                    Redback Networks
                                                          March 2003
                Definitions of Managed Objects
            for Synchronous Optical Network (SONET)
   Linear Automatic Protection Switching (APS) Architectures

Status of this Memo

This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited.

Copyright Notice

Copyright (C) The Internet Society (2003). All Rights Reserved.

Abstract

This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in TCP/IP based internets. In particular, it defines objects for managing networks using Synchronous Optical Network (SONET) linear Automatic Protection Switching (APS) architectures.

Introduction

This memo defines a portion of the Management Information Base (MIB) used for managing SONET linear Automatic Protection Switching (APS) architectures. Two linear APS architectures are supported, the 1+1 architecture and the 1:n architecture.

The Internet-Standard Management Framework

For a detailed overview of the documents that describe the current Internet-Standard Management Framework, please refer to section 7 of RFC 3410 RFC3410.

Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. MIB objects are generally accessed through the Simple Network Management Protocol (SNMP). Objects in the MIB are defined using the mechanisms defined in the Structure of Management Information (SMI). This memo specifies a MIB module that is compliant to the SMIv2, which is described in STD 58, RFC 2578 RFC2578, STD 58, RFC 2579 RFC2579 and STD 58, RFC 2580 RFC2580.

Overview

These objects are used to control and manage SONET linear APS architectures. Ring APS groups are not currently supported by this MIB.

The MIB includes three scalars, containing counts of APS groups and SONET LTEs, a notification enable object, and six tables.

The apsMapTable contains entries for each SONET LTE interface available on the system. The table serves two purposes. It can be used to locate SONET LTE interfaces that are not currently included in APS groups. It also provides a mapping from InterfaceIndex to group name and channel number for those SONET LTE interfaces that are included in APS groups. Entries in apsMapTable cannot be added or deleted through operations defined in this MIB. However, an apsMapEntry may be added or deleted through other system mechanisms, such as hot swap. Also, existing entries cannot be directly modified and instead, such modifications occur as a result of side-effects of operations on the apsChanConfigTable.

The apsChanConfigTable supports addition, modification and deletion of entries representing linear APS channels. Entries are indexed by a text group name and integer channel number. Each entry contains an InterfaceIndex value identifying the SONET LTE used for the channel and the priority of the channel. A side effect of row creation or

deletion is the setting of map entry fields. Creation of two or more entries in this table with a common group name index and consecutive channel numbers is the first step in the creation and configuration of an APS group. It is not necessary to create channel numbers in order; however, before an APS group is made active, the set of channels must begin with channel number 0 (for architectures other than onePlusOneOptimized) or channel number 1 (for the onePlusOneOptimized architecture) and must have consecutive channel numbers not exceeding 14. Note that the term null channel, which is used throughout this document, refers to the protection line.

The apsConfigTable supports addition, modification, and deletion of entries representing linear APS groups. Entries are indexed by a text group name. Each entry contains parameters that specify the configuration of a particular linear APS group. Entries are created in this table after a set of channels are created in the apsChanConfigTable. To successfully set an instance of apsConfigRowStatus to active the apsConfigEntry must contain valid values and all associated apsChanConfigEntry rows must be valid and produce a consecutive set of channels beginning with channel number 0 or 1, depending on the selected architecture.

The apsCommandTable provides linear APS commands that support protection switching and the ability to modify APS operation. Entries in this table are created as a side effect of setting the associated apsConfigRowStatus object to active. Entries in this table are deleted if the associated apsConfigRowStatus object is set to any value except active.

The apsChanStatusTable provides individual channel statistics.

The apsStatusTable provides group level statistics.

An APS group is created and configured with the following sequence of events:

CHANNEL CONFIGURATION

Create an entry in the apsChanConfigTable. Set the apsChanConfigGroupName in an apsChanConfigEntry to a user-friendly text string which will serve as the APS group name. The string must not be equal to the apsConfigName of an existing apsConfigEntry with apsConfigRowStatus set to active, since a channel cannot be added to an active group. The string may be set equal to the apsConfigName of a row which is currently not set to active, or it may be set to a string which does not currently exist in any instance of apsConfigName. A channel number is entered in apsChanConfigNumber. A channel priority is entered in apsChanConfigPriority, if the

intended architecture is 1:n. apsChanConfigPriority is ignored if the architecture is 1+1. The InterfaceIndex value of a SONET LTE interface is entered in apsChanConfigIfIndex.

This step is repeated for all apsChanConfigEntry instances which are to be included in the APS group.

ACTIVATING THE GROUP

If the apsChanConfigGroupName does not exist in an instance of apsConfigName, an apsConfigEntry is created with the apsChanConfigGroupName value used as the index for the row. The apsConfigRowStatus value may be set to createAndGo. The apsGroupConfigEntry and apsChanConfigEntry instances with matching name fields will be checked for consistency. If any errors in the channel numbers, architecture or configuration are uncovered the apsConfigRowStatus set will return inconsistentValue, otherwise noError is returned.

If the apsChanConfigGroupName value used in channel configuration exists in a previously created, inactive apsConfigEntry instance, the apsConfigRowStatus value may be set to active.

An agent is not required to process SNMP Set Requests that affect multiple control objects within this MIB. This is intended to simplify the processing of Set Requests for the various control tables by eliminating the possibility that a single Set PDU will contain multiple varbinds which are in conflict, such as a PDU which both activates a given apsConfigEntry while at the same time it deactivates an associated apsChanConfigEntry.

Definitions

APS-MIB DEFINITIONS ::= BEGIN

IMPORTS

    MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
    Gauge32, Counter32, Integer32, transmission
            FROM SNMPv2-SMI
    TEXTUAL-CONVENTION, RowStatus,
    TimeStamp, StorageType
            FROM SNMPv2-TC
    SnmpAdminString
            FROM SNMP-FRAMEWORK-MIB
    ifIndex, InterfaceIndex
            FROM IF-MIB
    MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
            FROM SNMPv2-CONF;

apsMIB MODULE-IDENTITY

LAST-UPDATED        "200302280000Z"  -- February 28, 2003
ORGANIZATION        "IETF AToMMIB Working Group"
CONTACT-INFO
    "       Jim Kuhfeld
            Postal: RedBack Networks. Inc.
            300 Holger Way
            San Jose, CA 95134-1362
            Tel: +1 408 750 5465
            Email: [email protected]
            Jeff Johnson
            Postal: RedBack Networks. Inc.
            300 Holger Way
            San Jose, CA 95134-1362
            Tel: +1 408 750 5460
            Email: [email protected]
            Michael Thatcher
            Postal: RedBack Networks. Inc.
            300 Holger Way
            San Jose, CA 95134-1362
            Tel: +1 408 750 5449
            Email: [email protected]"
DESCRIPTION
    "This management information module supports the configuration
     and management of SONET linear APS groups. The definitions and
     descriptions used in this MIB have been derived from
     Synchronous Optical Network (SONET) Transport Systems:
     Common Generic Criteria, GR-253-CORE Issue 3, September 2000,
     section 5.3. The MIB is also consistent with the Multiplex
     Section Protection (MSP) protocol as specified in ITU-T
     Recommendation G.783, Characteristics of synchronous digital
     hierarchy (SDH) equipment function blocks, Annex A and B.
     Copyright (C) The Internet Society (2003).  This version of
     this MIB module is part of RFC 3498; see the RFC itself for
     full legal notices.
     "
REVISION      "200302280000Z"  -- February 28, 2003
DESCRIPTION
      "Initial version of this MIB, published as RFC 3498."
    ::= { transmission 49 }

apsMIBObjects OBJECT IDENTIFIER

    ::= { apsMIB 1 }

apsMIBNotifications OBJECT IDENTIFIER

    ::= { apsMIB 2 }

apsMIBConformance OBJECT IDENTIFIER

    ::= { apsMIB 3 }

ApsK1K2 ::= TEXTUAL-CONVENTION

STATUS current
DESCRIPTION
    "This Textual Convention describes an object that stores
     a SONET K1 and K2 byte APS protocol field.
     K1 is located in the first octet, K2 is located in
     the second octet. Bits are numbered from left to right.
     Bits 1-4 of the K1 byte indicate a request.
     1111  Lockout of Protection
     1110  Forced Switch
     1101  SF - High Priority
     1100  SF - Low Priority
     1011  SD - High Priority
     1010  SD - Low Priority
     1001  not used
     1000  Manual Switch
     0111  not used
     0110  Wait-to-Restore
     0101  not used
     0100  Exercise
     0011  not used
     0010  Reverse Request
     0001  Do Not Revert
     0000  No Request
     Bits 5-8 of the K1 byte indicate the channel associated with
     the request defined in bits 1-4.
     0000 is the Null channel.
     1-14 are working channels.
     15   is the extra traffic channel
     Bits 1-4 of the K2 byte indicate a channel. The channel is
     defined with the same syntax as K1 Bits 5-8.
     Bit 5 of the K2 byte indicates the
     architecture.
     0 if the architecture is 1+1
     1 if the architecture is 1:n
     Bits 6-8 of the K2 byte indicates the mode.
     000 - 011 are reserved for future use
     100  indicates the mode is unidirectional
     101  indicates the mode is bidirectional
     110  RDI-L
     111  AIS-L
    "
REFERENCE
    "Bellcore (Telcordia Technologies) GR-253-CORE, Issue 3,
    September 2000, 5.3.5."
SYNTAX      OCTET STRING (SIZE (2))

ApsSwitchCommand ::= TEXTUAL-CONVENTION

STATUS       current
DESCRIPTION
    "An APS switch command allows a user to perform protection
     switch actions.
     If the APS switch command cannot be executed because an
     equal or higher priority request is in effect, an
     inconsistentValue error is returned.
     The Switch command values are:
     noCmd
     This value should be returned by a read request when no switch
     command has been written to the object in question since
     initialization. This value may not be used in a write
     operation.  If noCmd is used in a write operation a wrongValue
     error is returned.
     clear
     Clears all of the switch commands listed below for the
     specified channel.
     lockoutOfProtection
     Prevents any of the working channels from switching to the
     protection line. The specified channel should be the protection
     channel, otherwise an inconsistentValue error is returned.
     forcedSwitchWorkToProtect
     Switches the specified working channel to the protection line.
     If the protection channel is specified an inconsistentValue
     error is returned.
     forcedSwitchProtectToWork
     Switches the working channel back from the protection
     line to the working line. The specified channel should be
     the protection channel, otherwise an inconsistentValue
     error is returned.
     manualSwitchWorkToProtect
     Switches the specified working channel to the protection line.
     If the protection channel is specified an inconsistentValue
     error is returned.
     manualSwitchProtectToWork
     Switches the working channel back from the protection
     line to the working line. The specified channel should be
     the protection channel, otherwise an inconsistentValue
     error is returned.
     exercise
     Exercises the protocol for a protection switch of the specified
     channel by issuing an Exercise request for that channel and
     checking the response on the APS channel. "
SYNTAX       INTEGER {
                 noCmd(1),
                 clear(2),
                 lockoutOfProtection(3),
                 forcedSwitchWorkToProtect(4),
                 forcedSwitchProtectToWork(5),
                 manualSwitchWorkToProtect(6),
                 manualSwitchProtectToWork(7),
                 exercise(8)
             }

ApsControlCommand ::= TEXTUAL-CONVENTION

STATUS       current
DESCRIPTION
    "An APS control command applies only to LTE that support the
     1:n architecture and performs the following actions.
     The Control command values are:
     noCmd
     This value should be returned by a read request when no control
     command has been written to the object in question since
     initialization. This value may not be used in a write
     operation.  If noCmd is used in a write operation a wrongValue
     error is returned.
     lockoutWorkingChannel
     Prevents the specified working channel from switching to the
     protection line. If the protection line is specified an
     inconsistentValue error is returned.
     clearLockoutWorkingChannel
     Clears the lockout a working channel command for the channel
     specified. If the protection line is specified an
     inconsistentValue error is returned."
SYNTAX       INTEGER {
                 noCmd(1),
                 lockoutWorkingChannel(2),
                 clearLockoutWorkingChannel(3)
             }

-- -- APS Configuration Table -- -- This table supports the addition, configuration and deletion of APS -- groups. --

apsConfig OBJECT IDENTIFIER ::= { apsMIBObjects 1 }

apsConfigGroups OBJECT-TYPE

SYNTAX      Gauge32
MAX-ACCESS  read-only
STATUS      current
DESCRIPTION
    "The count of APS groups. This count includes all rows in
     apsConfigTable, regardless of the value of apsConfigRowStatus."
::= { apsConfig 1 }

apsConfigTable OBJECT-TYPE

SYNTAX      SEQUENCE OF ApsConfigEntry
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "This table lists the APS groups that have been configured
     on the system."
::= { apsConfig 2 }

apsConfigEntry OBJECT-TYPE

SYNTAX      ApsConfigEntry
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "A conceptual row in the apsConfigTable."
INDEX { IMPLIED apsConfigName }
::= { apsConfigTable  1 }

ApsConfigEntry ::= SEQUENCE {

apsConfigName                  SnmpAdminString,
apsConfigRowStatus             RowStatus,
apsConfigMode                  INTEGER,
apsConfigRevert                INTEGER,
apsConfigDirection             INTEGER,
apsConfigExtraTraffic          INTEGER,
apsConfigSdBerThreshold        Integer32,
apsConfigSfBerThreshold        Integer32,
apsConfigWaitToRestore         Integer32,
apsConfigCreationTime          TimeStamp,
apsConfigStorageType           StorageType

}

apsConfigName OBJECT-TYPE

SYNTAX      SnmpAdminString (SIZE (1..32))
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "A textual name for the APS group."
::= { apsConfigEntry 1 }

apsConfigRowStatus OBJECT-TYPE

SYNTAX      RowStatus
MAX-ACCESS  read-create
STATUS      current
DESCRIPTION
    "The status of this APS group entry.
    An entry may not exist in the active state unless all
    objects in the entry have an appropriate value. Also,
    all associated apsChanConfigEntry rows must represent
    a set of consecutive channel numbers beginning with
    0 or 1, depending on the selected architecture.
    When set to notInService changes may be made to apsConfigMode,
    apsConfigRevert, apsConfigDirection, apsConfigExtraTraffic,
    apsConfigSdBerThreshold, apsConfigSfBerThreshold,
    and apsConfigWaitToRestore. Also, associated apsChanConfigTable
    objects may be added, deleted and modified."
::= { apsConfigEntry 2 }

apsConfigMode OBJECT-TYPE

SYNTAX      INTEGER {
                    onePlusOne(1),
                    oneToN(2),
                    onePlusOneCompatible(3),
                    onePlusOneOptimized(4)
                    }
MAX-ACCESS  read-create
STATUS      current
DESCRIPTION
   "The architecture of the APS group.
    onePlusOne
    The 1+1 architecture permanently bridges the working
    line to the protection line.
    oneToN
    The 1:n architecture allows one protection channel to
    protect up to n working channels. When a fault is detected
    on one of the n working channels that channel is bridged
    over the protection channel.
    onePlusOneCompatible
    This refers to 1 + 1 bidirectional switching compatible with
    1:n bidirectional switching as specified in ITU-T
    Recommendation G.783 (04/97) section A.3.4.1. Since this
    mode necessitates bidirectional switching, apsConfigDirection
    must be set to bidirectional whenever onePlusOneCompatible
    is set.
    onePlusOneOptimized
    This refers to 1 + 1 bidirectional switching optimized
    for a network using predominantly 1 + 1 bidirectional
    switching as specified in ITU-T Recommendation G.783 (04/97)
    section B.1. Since this mode necessitates bidirectional
    switching, apsConfigDirection must be set to bidirectional
    whenever onePlusOneOptimized is set.
    This object may not be modified if the associated
    apsConfigRowStatus object is equal to active(1)."
DEFVAL {onePlusOne}
::= { apsConfigEntry 3 }

apsConfigRevert OBJECT-TYPE

SYNTAX      INTEGER { nonrevertive(1), revertive(2) }
MAX-ACCESS  read-create
STATUS      current
DESCRIPTION
   "The revertive mode of the APS group.
    nonrevertive
    Traffic remains on the protection line until another switch
    request is received.
    revertive
    When the condition that caused a switch to the protection
    line has been cleared the signal is switched back to the
    working line. Since switching is revertive with the 1:n
    architecture, apsConfigRevert must be set to revertive if
    apsConfigMode is set to oneToN.
    Switching may optionally be revertive with the 1+1 architecture.
    This object may not be modified if the associated
    apsConfigRowStatus object is equal to active(1). "
DEFVAL { nonrevertive }
::= { apsConfigEntry 4 }

apsConfigDirection OBJECT-TYPE

SYNTAX      INTEGER { unidirectional(1), bidirectional(2) }
MAX-ACCESS  read-create
STATUS      current
DESCRIPTION
   "The directional mode of the APS group.
    unidirectional
    The unidirectional mode provides protection in one direction.
    bidirectional
    The bidirectional mode provides protection in both
    directions.
    This object may not be modified if the associated
    apsConfigRowStatus object is equal to active(1). "
DEFVAL {unidirectional}
::= { apsConfigEntry 5 }

apsConfigExtraTraffic OBJECT-TYPE

SYNTAX      INTEGER { enabled(1), disabled(2) }
MAX-ACCESS  read-create
STATUS      current
DESCRIPTION
   "This object enables or disables the transfer of extra traffic
    on the protection channel in a 1:n architecture. This object
    must be set to disabled if the architecture is 1+1. It may be
    necessary to disable this in order to interwork with other SONET
    network elements that don't support extra traffic.
    This object may not be modified if the associated
    apsConfigRowStatus object is equal to active(1). "
DEFVAL { disabled }
::= { apsConfigEntry 6 }

apsConfigSdBerThreshold OBJECT-TYPE

SYNTAX      Integer32 (5..9)
MAX-ACCESS  read-create
STATUS      current
DESCRIPTION
    "The Signal Degrade Bit Error Rate.
     The negated value of this number is used as the exponent of
     10 for computing the threshold value for the Bit Error Rate
     (BER). For example, a value of 5 indicates a BER threshold of
     10^-5.
     This object may be modified if the associated
     apsConfigRowStatus object is equal to active(1)."
DEFVAL { 5 }
::= { apsConfigEntry 7 }

apsConfigSfBerThreshold OBJECT-TYPE

SYNTAX      Integer32 (3..5)
MAX-ACCESS  read-create
STATUS      current
DESCRIPTION
    "The Signal Failure Bit Error Rate.
     The negated value of this number is used as the exponent of
     10 for computing the threshold value for the Bit Error Rate
     (BER). For example, a value of 5 indicates a BER threshold of
     10^-5.
     This object may be modified if the associated
     apsConfigRowStatus object is equal to active(1)."
DEFVAL { 3 }
::= { apsConfigEntry 8 }

apsConfigWaitToRestore OBJECT-TYPE

SYNTAX      Integer32 (0..720)
UNITS       "seconds"
MAX-ACCESS  read-create
STATUS      current
DESCRIPTION
    "The Wait To Restore period in seconds.
     After clearing of a condition that necessitated an
     automatic switch, the wait to restore period must elapse
     before reverting. This is intended to avoid rapid switch
     oscillations.
     GR-253-CORE specifies a Wait To Restore range of 5 to 12
     minutes. G.783 defines a 5 to 12 minute Wait To Restore
     range in section 5.4.1.1.3, but also allows for a shorter
     WTR period in  Table 2-1,
     WaitToRestore value (MI_WTRtime: 0..(5)..12 minutes).
     This object may not be modified if the associated
     apsConfigRowStatus object is equal to active(1)."
DEFVAL { 300 }
::= { apsConfigEntry 9 }

apsConfigCreationTime OBJECT-TYPE

SYNTAX      TimeStamp
MAX-ACCESS  read-only
STATUS      current
DESCRIPTION
    "The value of sysUpTime at the time the row was
     created"
::= { apsConfigEntry 10 }

apsConfigStorageType OBJECT-TYPE

SYNTAX      StorageType
MAX-ACCESS  read-create
STATUS      current
DESCRIPTION
    "The storage type for this conceptual row.
     Conceptual rows having the value 'permanent' need not
     allow write-access to any columnar objects in the row."
DEFVAL      { nonVolatile }
::= { apsConfigEntry 11 }

-- -- APS Status Table -- -- This table provides APS group statistics. --

apsStatusTable OBJECT-TYPE

SYNTAX      SEQUENCE OF ApsStatusEntry
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "This table provides status information about APS groups
     that have been configured on the system."
::= { apsMIBObjects 2 }

apsStatusEntry OBJECT-TYPE

SYNTAX      ApsStatusEntry
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "A conceptual row in the apsStatusTable."
AUGMENTS { apsConfigEntry }
::= { apsStatusTable  1 }

ApsStatusEntry ::= SEQUENCE {

apsStatusK1K2Rcv               ApsK1K2,
apsStatusK1K2Trans             ApsK1K2,
apsStatusCurrent               BITS,
apsStatusModeMismatches        Counter32,
apsStatusChannelMismatches     Counter32,
apsStatusPSBFs                 Counter32,
apsStatusFEPLFs                Counter32,
apsStatusSwitchedChannel       Integer32,
apsStatusDiscontinuityTime     TimeStamp

}

apsStatusK1K2Rcv OBJECT-TYPE

SYNTAX      ApsK1K2
MAX-ACCESS  read-only
STATUS      current
DESCRIPTION
    "The current value of the K1 and K2 bytes received on the
     protection channel."
::= { apsStatusEntry 1 }

apsStatusK1K2Trans OBJECT-TYPE

SYNTAX        ApsK1K2
MAX-ACCESS    read-only
STATUS        current
DESCRIPTION
    "The current value of the K1 and K2 bytes transmitted on the
     protection channel."
::= { apsStatusEntry 2 }

apsStatusCurrent OBJECT-TYPE

SYNTAX      BITS {
              modeMismatch(0),
              channelMismatch(1),
              psbf(2),
              feplf(3),
              extraTraffic(4)
             }
MAX-ACCESS  read-only
STATUS      current
DESCRIPTION
    "The current status of the APS group.
     modeMismatch
     Modes other than 1+1 unidirectional monitor protection line
     K2 bit 5, which indicates the architecture and K2 bits
     6-8, which indicate if the mode is unidirectional or
     bidirectional. A conflict between the current local mode
     and the received K2 mode information constitutes a
     mode mismatch.
     channelMismatch
     This bit indicates a  mismatch between the transmitted K1
     channel and the received K2 channel has been detected.
     psbf
     This bit indicates a Protection Switch Byte Failure (PSBF) is
     in effect. This condition occurs when either an inconsistent
     APS byte or an invalid code is detected. An inconsistent APS
     byte occurs when no three consecutive K1 bytes of the last 12
     successive frames are identical, starting with the last frame
     containing a previously consistent byte. An invalid code occurs
     when the incoming K1 byte contains an unused code or a code
     irrelevant for the specific switching operation (e.g., Reverse
     Request while no switching request is outstanding) in three
     consecutive frames. An invalid code also occurs when the
     incoming K1 byte contains an invalid channel number in three
     consecutive frames.
     feplf
     Modes other than 1+1 unidirectional monitor the K1 byte
     for Far-End Protection-Line failures. A Far-End
     Protection-Line defect is declared based on receiving
     SF on the protection line.
     extraTraffic
     This bit indicates whether extra traffic is currently being
     accepted on the protection line. "
::= { apsStatusEntry 3 }

apsStatusModeMismatches OBJECT-TYPE

SYNTAX     Counter32
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
    "A count of Mode Mismatch conditions.
     Discontinuities in the value of this counter can occur at
     re-initialization of the management system, and at other
     times as indicated by the value of
     apsStatusDiscontinuityTime."
::= { apsStatusEntry 4 }

apsStatusChannelMismatches OBJECT-TYPE

SYNTAX     Counter32
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
    "A count of Channel Mismatch conditions.
     Discontinuities in the value of this counter can occur at
     re-initialization of the management system, and at other
     times as indicated by the value of
     apsStatusDiscontinuityTime."
::= { apsStatusEntry 5 }

apsStatusPSBFs OBJECT-TYPE

SYNTAX     Counter32
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
    "A count of Protection Switch Byte Failure conditions.
     This condition occurs when either an inconsistent APS
     byte or an invalid code is detected. An inconsistent APS
     byte occurs when no three consecutive K1 bytes of the last
     12 successive frames are identical, starting with the last
     frame containing a previously consistent byte. An invalid
     code occurs when the incoming K1 byte contains an unused
     code or a code irrelevant for the specific switching
     operation (e.g., Reverse Request while no switching request
     is outstanding) in three consecutive frames. An invalid code
     also occurs when the incoming K1 byte contains an invalid
     channel number in three consecutive frames.
     Discontinuities in the value of this counter can occur at
     re-initialization of the management system, and at other
     times as indicated by the value of
     apsStatusDiscontinuityTime."
::= { apsStatusEntry 6 }

apsStatusFEPLFs OBJECT-TYPE

SYNTAX     Counter32
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
    "A count of Far-End Protection-Line Failure conditions.
     This condition is declared based on receiving SF on
     the protection line in the K1 byte.
     Discontinuities in the value of this counter can occur at
     re-initialization of the management system, and at other
     times as indicated by the value of
     apsStatusDiscontinuityTime."
::= { apsStatusEntry 7 }

apsStatusSwitchedChannel OBJECT-TYPE

SYNTAX     Integer32
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
    "This field is set to the number of the channel that is
     currently switched to protection. The value 0 indicates no
     channel is switched to protection. The values 1-14 indicate
     that working channel is switched to protection."
::= { apsStatusEntry 8 }

apsStatusDiscontinuityTime OBJECT-TYPE

SYNTAX      TimeStamp
MAX-ACCESS  read-only
STATUS      current
DESCRIPTION
    "The value of sysUpTime on the most recent occasion at which
     any one or more of this APS group's counters suffered a
     discontinuity.  The relevant counters are the specific
     instances associated with this APS group of any Counter32
     object contained in apsStatusTable. If no such
     discontinuities have occurred since the last re-initialization
     of the local management subsystem, then this object contains
     a zero value."
::= { apsStatusEntry 9 }

-- -- APS Map Group -- -- Lists the SONET LTE interfaces that may be used to create APS groups. --

apsMap OBJECT IDENTIFIER ::= { apsMIBObjects 3 }

apsChanLTEs OBJECT-TYPE

SYNTAX      Gauge32
MAX-ACCESS  read-only
STATUS      current
DESCRIPTION
    "The count of SONET LTE interfaces on the system.
     Each interface that is included has an ifType value of
     sonet(39)."
::= { apsMap 1 }

apsMapTable OBJECT-TYPE

SYNTAX      SEQUENCE OF ApsMapEntry
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "This table lists the SONET LTE interfaces on the system.
     Each interface that is listed has an ifType value of
     sonet(39)."
::= { apsMap 2 }

apsMapEntry OBJECT-TYPE

SYNTAX      ApsMapEntry
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "A conceptual row in the apsMapTable."
INDEX { ifIndex }
::= { apsMapTable  1 }

ApsMapEntry ::= SEQUENCE {

apsMapGroupName             SnmpAdminString,
apsMapChanNumber            Integer32

}

apsMapGroupName OBJECT-TYPE

SYNTAX      SnmpAdminString (SIZE (0..32))
MAX-ACCESS  read-only
STATUS      current
DESCRIPTION
    "A textual name for the APS group which this channel is
     included in. If the channel is not part of an APS group
     this value is set to a string of size 0.
     When an instance of apsChanConfigIfIndex is set equal to an
     instance of ifIndex that has an ifType value of sonet(39),
     apsMapGroupName is set equal to the corresponding value of
     apsChanConfigGroupName.
     If an instance of ifIndex that has an ifType value of
     sonet(39) ceases to be equal to an instance of
     apsChanConfigIfIndex, either because of a change in the value
     of apsChanConfigIfIndex, or because of row deletion in the
     ApsChanConfigTable, apsMapGroupName is set to a string of
     size 0."
::= { apsMapEntry 2 }

apsMapChanNumber OBJECT-TYPE

SYNTAX     Integer32 (-1..14)
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
    "This field is set to a unique channel number within an APS
     group.  The value 0 indicates the null channel. The values
     1-14 define a working channel. If the SONET LTE is not part
     of an APS group this value is set to -1.
     When an instance of apsChanConfigIfIndex is set equal to an
     instance of ifIndex that has an  ifType value of sonet(39),
     apsMapChanNumber is set equal to the corresponding value of
     apsChanConfigNumber.
     If an instance of ifIndex that has an  ifType value of
     sonet(39) ceases to be equal to an instance of
     apsChanConfigIfIndex, either because of a change in the
     value of apsChanConfigIfIndex, or because of row deletion
     in the ApsChanConfigTable, apsMapChanNumber is set to -1."
::= { apsMapEntry 3 }

-- -- APS Channel Configuration Table -- -- This table supports the addition, configuration and deletion of -- channels in APS groups. --

apsChanConfigTable OBJECT-TYPE

SYNTAX      SEQUENCE OF ApsChanConfigEntry
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "This table lists the APS channels that have been configured
     in APS groups."
::= { apsMIBObjects 4 }

apsChanConfigEntry OBJECT-TYPE

SYNTAX      ApsChanConfigEntry
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "A conceptual row in the apsChanConfigTable."
INDEX {apsChanConfigGroupName, apsChanConfigNumber}
::= { apsChanConfigTable  1 }

ApsChanConfigEntry ::= SEQUENCE {

apsChanConfigGroupName             SnmpAdminString,
apsChanConfigNumber                Integer32,
apsChanConfigRowStatus             RowStatus,
apsChanConfigIfIndex               InterfaceIndex,
apsChanConfigPriority              INTEGER,
apsChanConfigStorageType           StorageType

}

apsChanConfigGroupName OBJECT-TYPE

SYNTAX      SnmpAdminString (SIZE (1..32))
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "A textual name for the APS group which this channel is
     included in."
::= { apsChanConfigEntry 1 }

apsChanConfigNumber OBJECT-TYPE

SYNTAX     Integer32 (0..14)
MAX-ACCESS not-accessible
STATUS     current
DESCRIPTION
    "This field is set to a unique channel number within an APS
     group.  The value 0 indicates the null channel.  The values
     1-14 define a working channel.
     This field must be assigned a unique number within the group."
::= { apsChanConfigEntry 2 }

apsChanConfigRowStatus OBJECT-TYPE

SYNTAX      RowStatus
MAX-ACCESS  read-create
STATUS      current
DESCRIPTION
    "The status of this APS channel entry.
     An entry may not exist in the active state unless all
     objects in the entry have an appropriate value.
     A row in the apsChanConfigTable may not be created,
     deleted, set to notInService or otherwise modified
     if the apsChanConfigGroupName value is equal to an
     apsConfigName value and the associated apsConfigRowStatus
     object is equal to active. However, if the apsConfigRowStatus
     object is equal to notInService, a row may be created, deleted
     or modified. In other words, a channel may not be added,
     deleted or modified if the group is active.
     A row may be created with an apsChanConfigGroupName value
     that is not equal to any existing instance of apsConfigName.
     This action is the initial step in adding a SONET LTE to a
     new APS group.
     If this object is set to destroy, the associated instance
     of apsMapGroupName will be set to a string of size 0 and
     the apsMapChanNumber will be set to -1. The channel status
     entry will also be deleted by this action.
     apsChanConfigNumber must be set to a unique channel number
     within the APS group. The value 0 indicates the null channel.
     The values 1-14 define a working channel. When an attempt is
     made to set the  corresponding apsConfigRowStatus field to
     active the apsChanConfigNumber values of all entries with equal
     apsChanConfigGroupName fields must represent a set of
     consecutive integer values beginning with 0 or 1, depending on
     the architecture of the group, and ending with n, where n is
     greater than or equal to 1 and less than or equal to 14.
     Otherwise, the error inconsistentValue is returned to the
     apsConfigRowStatus set attempt."
::= { apsChanConfigEntry 3 }

apsChanConfigIfIndex OBJECT-TYPE

SYNTAX     InterfaceIndex
MAX-ACCESS read-create
STATUS     current
DESCRIPTION
    "The Interface Index assigned to a SONET LTE. This is an
     interface with ifType sonet(39). The value of this object
     must be unique among all instances of apsChanConfigIfIndex.
     In other words, a particular SONET LTE can only be configured
     in one APS group.
     This object cannot be set if the apsChanConfigGroupName
     instance associated with this row is equal to an instance of
     apsConfigName and the corresponding apsConfigRowStatus object
     is set to active.  In other words this value cannot be changed
     if the APS group is active. However, this value may be changed
     if the apsConfigRowStatus value is equal to notInService."
::= { apsChanConfigEntry 4 }

apsChanConfigPriority OBJECT-TYPE

SYNTAX     INTEGER {low(1), high(2)}
MAX-ACCESS read-create
STATUS     current
DESCRIPTION
    "The priority of the channel.
     This field determines whether high or low priority
     SD and SF codes are used in K1 requests.
     This field is only applicable if the channel is to be included
     in a group using the 1:n architecture. It is not applicable if
     the channel is to be included in a group using the 1+1
     architecture, and is ignored in that case.
     This object cannot be set if the apsChanConfigGroupName
     instance associated with this row is equal to an instance of
     apsConfigName and the corresponding apsConfigRowStatus object
     is set to active.  In other words this value cannot be changed
     if the APS group is active.  However, this value may be changed
     if the apsConfigRowStatus value is equal to notInService."
DEFVAL { low }
::= { apsChanConfigEntry 5 }

apsChanConfigStorageType OBJECT-TYPE

SYNTAX      StorageType
MAX-ACCESS  read-create
STATUS      current
DESCRIPTION
    "The storage type for this conceptual row.
     Conceptual rows having the value 'permanent' need not
     allow write-access to any columnar objects in the row."
DEFVAL { nonVolatile }
::= { apsChanConfigEntry 6 }

-- -- APS Command Table -- -- This table provides the ability to initiate APS commands. --

apsCommandTable OBJECT-TYPE

SYNTAX      SEQUENCE OF ApsCommandEntry
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "This table allows commands to be sent to configured APS
      groups."
::= { apsMIBObjects 5 }

apsCommandEntry OBJECT-TYPE

SYNTAX      ApsCommandEntry
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "A conceptual row in the apsCommandTable. This row exists only
     if the associated apsConfigEntry is active."
INDEX {apsChanConfigGroupName, apsChanConfigNumber}
::= { apsCommandTable  1 }

ApsCommandEntry ::= SEQUENCE {

apsCommandSwitch         ApsSwitchCommand,
apsCommandControl        ApsControlCommand

}

apsCommandSwitch OBJECT-TYPE

SYNTAX      ApsSwitchCommand
MAX-ACCESS  read-write
STATUS      current
DESCRIPTION
    "Allows the initiation of an APS switch command on the
     APS group and channel specified by the index values.
     When read this object returns the last command written
     or noCmd if no command has been written to this
     channel since initialization. The return of the last command
     written does not imply that this command is currently in
     effect.  This request may have been preempted by a higher
     priority local or remote request. In order to determine the
     current state of the APS group it is necessary to read
     the objects apsStatusK1K2Rcv and apsStatusK1K2Trans.
     The value lockoutOfProtection should only be applied to the
     protection line channel since that switch command prevents any
     of the working channels from switching to the protection line.
     Following the same logic, forcedSwitchProtectToWork and
     manualSwitchProtectToWork should only be applied to the
     protection line channel.
     forcedSwitchWorkToProtect and manualSwitchWorkToProtect
     should only be applied to a working channel."
::= { apsCommandEntry 1 }

apsCommandControl OBJECT-TYPE

SYNTAX      ApsControlCommand
MAX-ACCESS  read-write
STATUS      current
DESCRIPTION
    "Allows the initiation of an APS control command on the
     APS group and channel specified by the index values.
     When read this object returns the last command written or
     noCmd if no command has been written to this channel since
     initialization.
     This object does not apply to the protection line."
::= { apsCommandEntry 2 }

-- -- APS Channel Status Table -- -- This table provides APS channel statistics. --

apsChanStatusTable OBJECT-TYPE

SYNTAX      SEQUENCE OF ApsChanStatusEntry
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "This table contains status information for all SONET LTE
     interfaces that are included in APS groups."
::= { apsMIBObjects 6 }

apsChanStatusEntry OBJECT-TYPE

SYNTAX      ApsChanStatusEntry
MAX-ACCESS  not-accessible
STATUS      current
DESCRIPTION
    "A conceptual row in the apsChanStatusTable."
AUGMENTS { apsChanConfigEntry }
::= { apsChanStatusTable  1 }

ApsChanStatusEntry ::= SEQUENCE {

apsChanStatusCurrent               BITS,
apsChanStatusSignalDegrades        Counter32,
apsChanStatusSignalFailures        Counter32,
apsChanStatusSwitchovers           Counter32,
apsChanStatusLastSwitchover        TimeStamp,
apsChanStatusSwitchoverSeconds     Counter32,
apsChanStatusDiscontinuityTime     TimeStamp

}

apsChanStatusCurrent OBJECT-TYPE

SYNTAX     BITS {
           lockedOut(0),
           sd(1),
           sf(2),
           switched(3),
           wtr(4)
        }
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
    "Indicates the current state of the port.
     lockedOut
     This bit, when applied to a working channel, indicates that
     the channel is prevented from switching to the protection
     line.  When applied to the null channel, this bit indicates
     that no working channel may switch to the protection line.
     sd
     A signal degrade condition is in effect.
     sf
     A signal failure condition is in effect.
     switched
     The switched bit is applied to a working channel if that
     channel is currently switched to the protection line.
     wtr
     A Wait-to-Restore state is in effect."
::= { apsChanStatusEntry 1 }

apsChanStatusSignalDegrades OBJECT-TYPE

SYNTAX     Counter32
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
    "A count of Signal Degrade conditions. This condition
     occurs when the line Bit Error Rate exceeds the currently
     configured value of the relevant instance of
     apsConfigSdBerThreshold.
     Discontinuities in the value of this counter can occur at
     re-initialization of the management system, and at other
     times as indicated by the value of
     apsChanStatusDiscontinuityTime."
::= { apsChanStatusEntry 2 }

apsChanStatusSignalFailures OBJECT-TYPE

SYNTAX     Counter32
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
    "A count of Signal Failure conditions that have been
     detected on the incoming signal. This condition occurs
     when a loss of signal, loss of frame, AIS-L or a Line
     bit error rate exceeding the currently configured value of
     the relevant instance of apsConfigSfBerThreshold.
     Discontinuities in the value of this counter can occur at
     re-initialization of the management system, and at other
     times as indicated by the value of
     apsChanStatusDiscontinuityTime."
::= { apsChanStatusEntry 3 }

apsChanStatusSwitchovers OBJECT-TYPE

SYNTAX     Counter32
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
    "When queried with index value apsChanConfigNumber other than
     0, this object will return the number of times this channel
     has switched to the protection line.
     When queried with index value apsChanConfigNumber set to 0,
     which is the protection line, this object will return the
     number of times that any working channel has been switched
     back to the working line from this protection line.
     Discontinuities in the value of this counter can occur at
     re-initialization of the management system, and at other
     times as indicated by the value of
     apsChanStatusDiscontinuityTime."
::= { apsChanStatusEntry 4 }

apsChanStatusLastSwitchover OBJECT-TYPE

SYNTAX     TimeStamp
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
    "When queried with index value apsChanConfigNumber other than
     0, this object will return the value of sysUpTime when this
     channel last completed a switch to the protection line. If
     this channel has never switched to the protection line, the
     value 0 will be returned.
     When queried with index value apsChanConfigNumber set to 0,
     which is the protection line, this object will return the
     value of sysUpTime the last time that a working channel was
     switched back to the working line from this protection line.
     If no working channel has ever switched back to the working
     line from this protection line, the value 0 will be returned."
::= { apsChanStatusEntry 5 }

apsChanStatusSwitchoverSeconds OBJECT-TYPE

SYNTAX     Counter32
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
    "The cumulative Protection Switching Duration (PSD) time in
     seconds. For a working channel, this is the cumulative number
     of seconds that service was carried on the protection line.
     For the protection line, this is the cumulative number of
     seconds that the protection line has been used to carry any
     working channel traffic. This information is only valid if
     revertive switching is enabled. The value 0 will be returned
     otherwise.
     Discontinuities in the value of this counter can occur at
     re-initialization of the management system, and at other
     times as indicated by the value of
     apsChanStatusDiscontinuityTime. For example, if the value
     of an instance of apsChanStatusSwitchoverSeconds changes
     from a non-zero value to zero due to revertive switching
     being disabled, it is expected that the corresponding
     value of apsChanStatusDiscontinuityTime will be updated
     to reflect the time of the configuration change.
     "
::= { apsChanStatusEntry 6 }

apsChanStatusDiscontinuityTime OBJECT-TYPE

SYNTAX      TimeStamp
MAX-ACCESS  read-only
STATUS      current
DESCRIPTION
    "The value of sysUpTime on the most recent occasion at which
     any one or more of this channel's counters suffered a
     discontinuity.  The relevant counters are the specific
     instances associated with this channel of any Counter32
     object contained in apsChanStatusTable. If no such
     discontinuities have occurred since the last re-initialization
     of the local management subsystem, then this object contains
     a zero value."
::= { apsChanStatusEntry 7 }

apsNotificationEnable OBJECT-TYPE

SYNTAX     BITS {
           switchover(0),
           modeMismatch(1),
           channelMismatch(2),
           psbf(3),
           feplf(4)
        }
MAX-ACCESS read-write
STATUS     current
DESCRIPTION
    "Provides the ability to enable and disable notifications
     defined in this MIB.
     switchover
     Indicates  apsEventSwitchover notifications
     should be generated.
     modeMismatch
     Indicates  apsEventModeMismatch notifications
     should be generated.
     channelMismatch
     Indicates  apsEventChannelMismatch notifications
     should be generated.
     psbf
     Indicates  apsEventPSBF notifications
     should be generated.
     feplf
     Indicates  apsEventFEPLF notifications
     should be generated. "
DEFVAL { { } }
::= { apsMIBObjects 7 }

-- -- APS EVENTS

--

apsNotificationsPrefix OBJECT IDENTIFIER

    ::= { apsMIBNotifications 0 }

apsEventSwitchover NOTIFICATION-TYPE

OBJECTS { apsChanStatusSwitchovers, apsChanStatusCurrent }
STATUS  current
DESCRIPTION
    "An apsEventSwitchover notification is sent when the
    value of an instance of apsChanStatusSwitchovers increments."
::= { apsNotificationsPrefix 1 }

apsEventModeMismatch NOTIFICATION-TYPE

OBJECTS { apsStatusModeMismatches, apsStatusCurrent }
STATUS  current
DESCRIPTION
    "An apsEventModeMismatch notification is sent when the
    value of an instance of apsStatusModeMismatches increments."
::= { apsNotificationsPrefix 2 }

apsEventChannelMismatch NOTIFICATION-TYPE

OBJECTS { apsStatusChannelMismatches, apsStatusCurrent }
STATUS  current
DESCRIPTION
    "An apsEventChannelMismatch notification is sent when the
    value of an instance of apsStatusChannelMismatches increments."
::= { apsNotificationsPrefix 3 }

apsEventPSBF NOTIFICATION-TYPE

OBJECTS { apsStatusPSBFs, apsStatusCurrent }
STATUS  current
DESCRIPTION
    "An apsEventPSBF notification is sent when the
    value of an instance of apsStatusPSBFs increments."
::= { apsNotificationsPrefix 4 }

apsEventFEPLF NOTIFICATION-TYPE

OBJECTS { apsStatusFEPLFs, apsStatusCurrent }
STATUS  current
DESCRIPTION
    "An apsEventFEPLFs notification is sent when the
    value of an instance of apsStatusFEPLFs increments."
::= { apsNotificationsPrefix 5 }

-- conformance information

apsGroups OBJECT IDENTIFIER ::= { apsMIBConformance 1 } apsCompliances OBJECT IDENTIFIER ::= { apsMIBConformance 2 }

apsFullCompliance MODULE-COMPLIANCE

STATUS  current
DESCRIPTION
    "When this MIB is implemented with support for read-create, then
    such an implementation can claim read/write compliance. Linear
    APS groups can then be both monitored and configured with this
    MIB.
    Note that An agent is not required to process SNMP Set Requests
    that affect multiple control objects within this MIB. This is
    intended to simplify the processing of Set Requests for the
    various control tables by eliminating the possibility that a
    single Set PDU will contain multiple varbinds which are in
    conflict. "
MODULE
MANDATORY-GROUPS { apsConfigGeneral, apsStatusGeneral,
                   apsChanGeneral }
    OBJECT  apsConfigRowStatus
    SYNTAX INTEGER { active(1) }
    WRITE-SYNTAX INTEGER { createAndGo(4), destroy(6) }
    DESCRIPTION
        "Support for createAndWait and notInService is not
         required."
    OBJECT  apsChanConfigRowStatus
    SYNTAX INTEGER { active(1) }
    WRITE-SYNTAX INTEGER { createAndGo(4), destroy(6) }
    DESCRIPTION
        "Support for createAndWait and notInService is not
         required."
    GROUP       apsConfigWtr
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations. The information is
         applicable to groups supporting a configurable
         WTR period."
    GROUP       apsCommandOnePlusOne
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations. The information is
         applicable to groups implementing the linear
         APS 1+1 architecture and supporting set operations."
   GROUP       apsCommandOneToN
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations. The information is
         applicable to groups implementing the linear
         APS 1:n architecture and supporting set operations."
   GROUP       apsChanOneToN
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations. The information is
         applicable to groups implementing the linear
         APS 1:n architecture."
   GROUP       apsTotalsGroup
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations."
   GROUP       apsMapGroup
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations."
   GROUP       apsEventGroup
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations."
::= { apsCompliances 1 }

-- -- Read-Only Compliance --

apsReadOnlyCompliance MODULE-COMPLIANCE

STATUS  current
DESCRIPTION
    "When this MIB is implemented without support for read-create
     (i.e. in read-only mode), then that implementation can claim
     read-only compliance. In that case, linear APS groups can be
     monitored but cannot be configured with this MIB."
MODULE
MANDATORY-GROUPS { apsConfigGeneral, apsStatusGeneral,
                   apsChanGeneral }
    OBJECT  apsConfigMode
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT  apsConfigRevert
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT  apsConfigDirection
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT  apsConfigExtraTraffic
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT  apsConfigSdBerThreshold
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT  apsConfigSfBerThreshold
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT  apsConfigWaitToRestore
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT  apsConfigRowStatus
    SYNTAX  INTEGER { active(1) }
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required, and active is the only status
         that needs to be supported."
    OBJECT  apsConfigStorageType
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT  apsChanConfigIfIndex
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT  apsChanConfigPriority
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT  apsChanConfigRowStatus
    SYNTAX  INTEGER { active(1) }
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required, and active is the only status
         that needs to be supported."
    OBJECT  apsChanConfigStorageType
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    OBJECT  apsNotificationEnable
    MIN-ACCESS  read-only
    DESCRIPTION
        "Write access is not required."
    GROUP       apsConfigWtr
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations. The information is
         applicable to groups supporting a configurable
         WTR period."
    GROUP       apsCommandOnePlusOne
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations. The information is
         applicable to groups implementing the linear
         APS 1+1 architecture and supporting set operations."
   GROUP       apsCommandOneToN
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations. The information is
         applicable to groups implementing the linear
         APS 1:n architecture and supporting set operations."
   GROUP       apsChanOneToN
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations. The information is
         applicable to groups implementing the linear
         APS 1:n architecture."
   GROUP       apsTotalsGroup
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations."
   GROUP       apsMapGroup
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations."
   GROUP       apsEventGroup
    DESCRIPTION
        "Implementation of this group is optional for all
         linear APS implementations."
::= { apsCompliances 2 }

-- units of conformance

apsConfigGeneral OBJECT-GROUP

OBJECTS
{
    apsConfigMode,
    apsConfigRevert,
    apsConfigDirection,
    apsConfigExtraTraffic,
    apsConfigSdBerThreshold,
    apsConfigSfBerThreshold,
    apsConfigCreationTime,
    apsConfigRowStatus,
    apsConfigStorageType,
    apsNotificationEnable
}
STATUS  current
DESCRIPTION
    "A collection of apsConfigTable objects providing configuration
     information applicable to all linear APS groups."
::= { apsGroups 1 }

apsConfigWtr OBJECT-GROUP

OBJECTS
{
    apsConfigWaitToRestore
}
STATUS  current
DESCRIPTION
    "The apsConfigTable object that provides information which is
     applicable to groups supporting a configurable WTR period."
::= { apsGroups 2 }

-- If set operations are not supported neither of the following two -- groups are implemented. If sets are supported only one of these -- groups is implemented for a linear APS group instance.

apsCommandOnePlusOne OBJECT-GROUP

OBJECTS
{
    apsCommandSwitch
}
STATUS  current
DESCRIPTION
    "The  apsCommandTable object which is applicable to groups
     implementing the linear APS 1+1 architecture. Also, set
     operations must be supported."
::= { apsGroups 3 }

apsCommandOneToN OBJECT-GROUP

OBJECTS
{
    apsCommandSwitch,
    apsCommandControl
}
STATUS  current
DESCRIPTION
    "A collection of apsCommandTable objects which are applicable to
     groups implementing the linear APS 1:n architecture. Also, set
     operations must be supported."
::= { apsGroups 4 }

apsStatusGeneral OBJECT-GROUP

OBJECTS
{
    apsStatusK1K2Rcv,
    apsStatusK1K2Trans,
    apsStatusCurrent,
    apsStatusModeMismatches,
    apsStatusChannelMismatches,
    apsStatusPSBFs,
    apsStatusFEPLFs,
    apsStatusSwitchedChannel,
    apsStatusDiscontinuityTime
}
STATUS  current
DESCRIPTION
    "A collection of apsStatusTable objects providing status
     information applicable to all linear APS groups."
::= { apsGroups 5 }

apsChanGeneral OBJECT-GROUP

OBJECTS
{
    apsChanConfigIfIndex,
    apsChanConfigRowStatus,
    apsChanConfigStorageType,
    apsChanStatusCurrent,
    apsChanStatusSignalDegrades,
    apsChanStatusSignalFailures,
    apsChanStatusSwitchovers,
    apsChanStatusLastSwitchover,
    apsChanStatusSwitchoverSeconds,
    apsChanStatusDiscontinuityTime

}

STATUS  current
DESCRIPTION
    "A collection of channel objects providing information
     applicable to all linear APS channels."
::= { apsGroups 6 }

apsChanOneToN OBJECT-GROUP

OBJECTS
{
    apsChanConfigPriority
}
STATUS  current
DESCRIPTION
    "The apsChanConfigTable object that provides information which
     is only applicable to groups implementing the linear APS 1:n
     architecture."
::= { apsGroups 7 }

apsTotalsGroup OBJECT-GROUP

OBJECTS
{
    apsConfigGroups,
    apsChanLTEs
}
STATUS  current
DESCRIPTION
    "A collection of objects providing optional counts of configured
     APS groups and SONET LTE interfaces."
::= { apsGroups 8 }

apsMapGroup OBJECT-GROUP

OBJECTS
{
    apsMapGroupName,
    apsMapChanNumber
}
STATUS  current
DESCRIPTION
    "A collection of apsMapTable objects providing a mapping
     from sonet(39) InterfaceIndex to group name and channel
     number for assigned APS channels and a list of unassigned
     sonet(39) interfaces."
::= { apsGroups 9 }

apsEventGroup NOTIFICATION-GROUP

NOTIFICATIONS {apsEventSwitchover, apsEventModeMismatch,
               apsEventChannelMismatch, apsEventPSBF,
               apsEventFEPLF }
STATUS    current
DESCRIPTION
    "A collection of SONET linear APS notifications."
::= { apsGroups 10 }

END

Intellectual Property

The IETF takes no position regarding the validity or scope of any intellectual property or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; neither does it represent that it has made any effort to identify any such rights. Information on the IETF's procedures with respect to rights in standards-track and standards-related documentation can be found in [BCP11]. Copies of claims of rights made available for publication and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementors or users of this specification can be obtained from the IETF Secretariat.

The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights which may cover technology that may be required to practice this standard. Please address the information to the IETF Executive Director.

Acknowledgments

This document is a product of the AToMMIB Working Group. A number of constructs from a separate draft submission by Ken Chapman have been included here. Suggestions by Orly Nicklass, Faye Ly, Ron Carmona, Kaj Tesink, C. M. Heard, Muly Ilan, and Mickey Spiegel have been incorporated. A quality review was provided by Lauren Heintz and an IESG review by John Flick and Bert Wijnen.

Normative References

RFC2578 McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,

         Rose, M. and S. Waldbusser, "Structure of Management
         Information Version 2 (SMIv2)", STD 58, RFC 2578, April
         1999.

RFC2579 McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,

         Rose, M. and S. Waldbusser, "Textual Conventions for
         SMIv2", STD 58, RFC 2579, April 1999.

RFC2580 McCloghrie, K., Perkins, D., Schoenwaelder, J., Case, J.,

         Rose, M. and S. Waldbusser, "Conformance Statements for
         SMIv2", STD 58, RFC 2580, April 1999.

RFC2863 McCloghrie, K. and F. Kastenholz, "The Interfaces Group

         MIB", RFC 2863, June 2000.

[GR253CO] GR-253-CORE Issue 3, September 2000

[G.783] ITU-T Recommendation G.783 (04/97)

Informative References

RFC3410 Case, J., Mundy, R., Partain, D. and B. Stewart,

         "Introduction and Applicability Statements for Internet-
         Standard Management Framework", RFC 3410, December 2002.

[BCP11] Hovey, R, "The Organizations Involved in the IETF Standards

         Process", BCP 11, RFC 2028, October 1996.

Security Considerations

There are a number of management objects defined in this MIB that have a MAX-ACCESS clause of read-write and/or read-create. Such objects may be considered sensitive or vulnerable in some network environments. The support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations. In particular, the APS command objects apsCommandSwitch and apsCommandControl and the APS configuration objects apsConfigRowStatus, apsConfigMode, apsConfigRevert, apsConfigDirection, apsConfigExtraTraffic, apsConfigSdBerThreshold, apsConfigSfBerThreshold, apsConfigWaitToRestore, apsConfigStorageType, apsChanConfigRowStatus, apsChanConfigIfIndex, apsChanConfigPriority, apsChanConfigStorageType and apsNotificationEnable have the potential of disrupting APS operations if set operations are performed with malicious intent.

SNMP versions prior to SNMPv3 did not include adequate security. Even if the network itself is secure (for example by using IPSec), there is no control as to who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB module.

It is recommended that implementers consider the security features as provided by the SNMPv3 framework (see RFC3410, section 8), including full support for the SNMPv3 cryptographic mechanisms (for authentication and privacy).

Further, deployment of SNMP versions prior to SNMPv3 is not recommended. Instead, it is recommended to deploy SNMPv3 and to enable cryptographic security. It is then a customer/operator responsibility to ensure that access to an instance of this MIB module is properly configured for only those principals (users) that have legitimate rights to GET or SET object instances.

10. Editors' Addresses

Jim Kuhfeld RedBack Networks. Inc. 300 Holger Way San Jose, CA 95134-1362

Phone: +1 408 750 5465 EMail: [email protected]

Jeff Johnson RedBack Networks. Inc. 300 Holger Way San Jose, CA 95134-1362

Phone: +1 408 750 5460 EMail: [email protected]

Michael Thatcher RedBack Networks. Inc. 300 Holger Way San Jose, CA 95134-1362

Phone: +1 408 750 5449 EMail: [email protected]

11. Full Copyright Statement

Copyright (C) The Internet Society (2003). All Rights Reserved.

This document and translations of it may be copied and furnished to others, and derivative works that comment on or otherwise explain it or assist in its implementation may be prepared, copied, published and distributed, in whole or in part, without restriction of any kind, provided that the above copyright notice and this paragraph are included on all such copies and derivative works. However, this document itself may not be modified in any way, such as by removing the copyright notice or references to the Internet Society or other Internet organizations, except as needed for the purpose of developing Internet standards in which case the procedures for copyrights defined in the Internet Standards process must be followed, or as required to translate it into languages other than English.

The limited permissions granted above are perpetual and will not be revoked by the Internet Society or its successors or assigns.

This document and the information contained herein is provided on an "AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Acknowledgement

Funding for the RFC Editor function is currently provided by the Internet Society.