RFC3877

From RFC-Wiki

Network Working Group S. Chisholm Request for Comments: 3877 Nortel Networks Category: Standards Track D. Romascanu

                                                               Avaya
                                                      September 2004
            Alarm Management Information Base (MIB)

Status of this Memo

This document specifies an Internet standards track protocol for the Internet community, and requests discussion and suggestions for improvements. Please refer to the current edition of the "Internet Official Protocol Standards" (STD 1) for the standardization state and status of this protocol. Distribution of this memo is unlimited.

Copyright Notice

Copyright (C) The Internet Society (2004).

Abstract

This memo defines a portion of the Management Information Base (MIB) for use with network management protocols in the Internet community. In particular, it describes management objects used for modelling and storing alarms.

Contents

The Internet-Standard Management Framework

For a detailed overview of the documents that describe the current Internet-Standard Management Framework, please refer to section 7 of RFC 3410 RFC3410.

Managed objects are accessed via a virtual information store, termed the Management Information Base or MIB. MIB objects are generally accessed through the Simple Network Management Protocol (SNMP). Objects in the MIB are defined using the mechanisms defined in the Structure of Management Information (SMI). This memo specifies a MIB module that is compliant to the SMIv2, which is described in STD 58, RFC 2578 RFC2578, STD 58, RFC 2579 RFC2579 and STD 58, RFC 2580 RFC2580.

Introduction

In traditional SNMP management, problems are detected on an entity either through polling interesting MIB variables, waiting for the entity to send a Notification for a problem, or some combination of the two. This method is somewhat successful, but experience has shown some problems with this approach. Managers monitoring large numbers of entities cannot afford to be polling large numbers of objects on each device. Managers trying to ensure high reliability are unable to accurately determine whether any problems had occurred when they were not monitoring an entity. Finally, it can be time consuming for managers to try to understand the relationships between the various objects they poll, the Notifications they receive and the problems occurring on the entity. Even after detailed analysis they may still be left with an incomplete picture of what problems are occurring. But, it is important for an operator to be able to determine current problems on a system, so they can be fixed.

This memo describes a method of using alarm management in SNMP to address these problems. It also provides the necessary MIB objects to support this method.

Alarms and other terms related to alarm management are defined in the following sections.

The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in BCP 14, RFC 2119 RFC2119.

Alarm Management Framework

Terminology

Error

  A deviation of a system from normal operation.

Fault

  Lasting error or warning condition.

Event

  Something that happens which may be of interest.  A fault, a
  change in status, crossing a threshold, or an external input to
  the system, for example.

Notification

  Unsolicited transmission of management information.

Alarm

  Persistent indication of a fault.

Alarm State

  A condition or stage in the existence of an alarm.  As a minimum,
  alarms states are raise and clear.  They could also include
  severity information such as defined by perceived severity in the
  International Telecommunications Union (ITU) model [M.3100] -
  cleared, indeterminate, critical, major, minor and warning.

Alarm Raise

  The initial detection of the fault indicated by an alarm or any
  number of alarm states later entered, except clear.

Alarm Clear

  The detection that the fault indicated by an alarm no longer
  exists.

Active Alarm

  An alarm which has an alarm state that has been raised, but not
  cleared.

Alarm Detection Point

  The entity that detected the alarm.

Perceived Severity

  The severity of the alarm as determined by the alarm detection
  point using the information it has available.

Alarm Management Architecture

       +------------------------------------------------+
       |                                                |
       |  +------------------------------------+        |
       |  | Notification Management            |        |
       |  +------------------------------------+        |
       |          |                                     |
       +------------------------------------------------+
                  |
                  |
                  |
                  |<----------------------------------------------+
                  |                                               |

+------------------V-------------+ | | +---------------V-----------+ | | | | RFC 3413 | | | | | SNMP-NOTIFICATION-MIB | | | | +--------+--------------+-+-+ | | | | | | | | | | | +------------------+ | | | | | | | | | | | +----------V--------------+ | | | | | | +--------V---------+ | | | +---------V------------+ | | | | Alarm Modelling | | | | | RFC 3014 | | | | | (descriptions) | | | | | NOTIFICATION-LOG-MIB | | | | +--------+---------+ | | | +----------------------+ | | | | | | | | | | +--------V------------+ | | | +------------------------V-+ | | | Generic: Model- | | | | | RFC 3413 | | | | Active : Specific | | | | | SNMP-TARGET-MIB | | | | Alarms : Extensions | | | | +----------+---------------+ | | +--------+------------+ | | | | | | | | | +------------|-------------------+ +----------|--------------+ |

            |                                  |                  |
            |                                  +------------------+
            V
     Informs & Traps

Features of this Architecture

Modular Alarm Architecture

The subject of alarm management can potentially cover a large number of topics including real-time alarms, historical alarms, alarm correlation, and alarm suppression, to name a few. Within each of these topics, there are a number of established models that could be

supported. This memo focuses on a subset of this problem space, but describes a modular SNMP alarm management framework. Alarms SHOULD be modelled so Notifications are sent on alarm Clear.

The framework defines a generic Alarm MIB that can be supported on its own, or with additional alarm modelling information such as the provided ITU Alarm MIB. In addition, the active alarm tables could also be extended to support additional information about active alarm instances. This framework can also be expanded in the future to support such features as alarm correlation and alarm suppression. This modular architecture means that the cost of supporting alarm management features is proportional to the number of features an implementation supports.

Flexible Alarm Modelling

Alarm models document an understanding between a manager and an agent as to what problems will be reported on a system, how these problems will be reported, and what might possibly happen over the lifetime of this problem.

The alarm modelling method provided in this memo provides flexibility to support implementations with different modelling requirements. All alarms are modelled as a series of states that are related together using an alarm ID. Alarm states can be modelled using traditional Notifications, generic alarm Notifications, or without the use of Notifications.

Alarm states modelled using traditional Notifications would specify a Notification Object Identifier, and optionally an (offset, value) pair of one of the Notification varbinds to identify the state. This alarm state would be entered when the entity generated a Notification that matched this information and the alarm would be added to the active alarm table. This Notification would also get sent on the wire to any destinations, as indicated in the SNMP-TARGET-MIB and SNMP-NOTIFICATION-MIB RFC3413.

Alarm states modelled using generic Notifications use the alarmActiveState or alarmClearState Notifications defined in this memo. These alarm states would be entered after being triggered by a stimulus outside the scope of this memo, the alarm would be added to the active alarm table and these generic Notifications would then be sent on the wire to any destinations, as indicated in the SNMP- TARGET-MIB and SNMP-NOTIFICATION-MIB RFC3413.

Alarm states modelled without any Notifications would be triggered by some stimulus outside the scope of this memo, the alarm would be added to the active alarm table, but no Notifications would be sent to interested managers.

Problem Indication

The Alarm MIB provides a means to determine whether a given notification is of interest to managers for purposes of alarm management by permitting inspection of the alarm models. If no entries in the alarmModelTable could match a particular notification, then that notification is not relevant to the alarm models defined. In addition, information in the alarm model, such as the Notification ID and the description tell exactly what error or warning condition this alarm is indicating. If the ITU-ALARM-MIB is also supported, additional information is provided via the probable cause.

Identifying Resource under Alarm

An important goal of alarm management is to ensure that any detected problems get fixed, so it is necessary to know exactly where this problem is occurring. In addition, it is necessary to be able to tell when alarm instances are raised against the same component, as well as to be able to tell what instance of an alarm is cleared by an instance of an alarm clear.

The Alarm MIB provides a generic method for identifying the resource by extracting and building a resource ID from the Notification varbinds. It records the relevant information needed to locate the source of the alarm.

Means of obtaining ITU alarm information

Alarm Information, as defined in ITU alarm models [M.3100], is optionally available to implementations through the optional support of the ITU-ALARM-MIB.

Configuration of Alarm Models

An alarm model can be added and removed during runtime. It can be modified assuming it is not being referenced by any active alarm instance.

Active Alarm Management

A list of currently active alarms and supporting statistics on the SNMP entity can be obtained.

This allows the network management station to find out about any problems that may have occurred before it started managing a particular network element, or while it was out of contact with it.

Distributed Alarm Management

All aspects of the Alarm MIB can be supported both on the device experiencing the alarms and on any mid-level managers that might be monitoring such devices.

3.3.10. Historical Alarm Management

Some systems may have a requirement that information on alarms that are no longer active is available. This memo provides a clear table to support this requirement.

This can also be achieved through the support of the Notification Log MIB RFC3014 to store alarm state transitions.

Security

Given the nature of VACM, security for alarms is awkward since access control for the objects in the underlying Notifications can be checked only where the Notification is created. Thus such checking is possible only for locally generated Notifications, and even then only when security credentials are available.

For the purpose of this discussion, "security credentials" means the input values for the abstract service interface function isAccessAllowed RFC3411 and using those credentials means conceptually using that function to see that those credentials allow access to the MIB objects in question, operating as for a Notification Originator in RFC3413.

The Alarm MIB has the notion of a named alarm list. By using alarm list names and view-based access control RFC3415 a network administrator can provide different access for different users. When an application creates an alarm model (indexed in part by the alarm list name) the security credentials of the creator remain associated with that alarm model and constrain what information is allowed to be placed in the active alarm table, the active alarm variable table, the cleared alarm table, and the ITU alarm table.

When processing locally-generated Notifications, the managed system MUST use the security credentials associated with each alarm model respectively, and MUST apply the same access control rules as described for a Notification Originator in RFC3413.

The managed system SHOULD NOT apply access control when processing remotely-generated Notifications using the alarm models. In those cases the security of the information in the alarm tables SHOULD be left to the normal, overall access control for those tables.

Relationship between Alarm and Notifications

It is important to understand the relationship between alarms and Notifications, as both are traditional fault management methods. This relationship is modelled using the alarmModelTable to define the alarmModelNotificationId for each alarm state.

Not all Notifications signal an alarm state transition. Some Notifications are simply informational in nature, such as those that indicate that a configuration operation has been performed on an entity. These sorts of Notifications would not be represented in the Alarm MIB.

The Alarm MIB allows the use of the Notification space as defined in RFC2578 in order to identify the Notifications that are related with the specific alarm state transitions. However there is no assumption that the respective Notifications must be sent for all or any of the alarm state transitions. It is also possible to model alarms using no Notifications at all. This architecture allows for both the efficient exploitation of the body of defined Notification and for the use of non-Notification based systems.

Notification Varbind Storage and Reference

In SNMPv1 RFC1157, the varbinds in the Trap-PDU sent over the wire map one to one into those varbinds listed in the SMI of the trap in the MIB in which it was defined RFC1215. In the case of linkDown trap, the first varbind can unambiguously be identified as ifIndex. With the introduction of the InformRequest-PDU and SNMPv2-Trap-PDU types, which send sysUptime and snmpTrapOID as the first two varbinds, while the SMI in the MIB where the Notification is defined only lists additional varbinds, the meaning of "first varbind" becomes less clear. In the case of the linkDown Notification, referring to the first varbind could potentially be interpreted as either the sysUptime or ifIndex.

The varbind storage approach taken in the Alarm MIB is that sysUptime and snmpTrapOID SHALL always be stored in the active alarm variable table as entry 1 and 2 respectively, regardless of whether the transport was the Trap-PDU, the InformRequest-PDU or the SNMPv2- Trap-PDU. If the incoming Notification is an SNMPv1 Trap-PDU then an appropriate value for sysUpTime.0 or snmpTrapOID.0 shall be determined by using the rules in section 3.1 of RFC3584.

The varbind reference approach taken in the Alarm MIB is that, for variables such as the alarmModelVarbindIndex, the first two obligatory varbinds of the InformRequest-PDU and SNMPv2-Trap-PDU need to be considered so the index values of the Trap-PDU and the SMI need be adjusted by two. In the case of linkDown, the third varbind would always be ifIndex.

Relation to Notification Log MIB

The Alarm MIB is intended to complement the Notification Log MIB RFC3014, but can be used independently. The alarmActiveTable is defined in manner similar to that of the nlmLogTable. This format allows for the storage of any Trap or Notification type that can be defined using the SMI, or can be carried by SNMP. Using the same format as the Notification Log MIB also simplifies operations for systems choosing to implement both MIBs.

The object alarmActiveLogPointer points, for each entry in the alarmActiveLogTable, to the log index in the Notification Log MIB, if used.

If the Notification Log MIB is supported, it can be monitored by a management system as a hedge against lost alarms. The Notification Log can also be used to support historical alarm management.

Relationship with the Event MIB

During the work and discussions in the Working Group, the issue of the relationship between the MIB modules and the Event MIB RFC2981 was raised. There is no direct relation or dependency between the Alarm MIB and the Event MIB. Some common terms (like 'event') are being used in both MIB modules, and the user is directed to the sections that define terminology in the two documents for clarification.

Generic Alarm MIB

Overview

The ALARM-MIB consists of alarm models and lists of active and cleared alarms.

The alarmModelTable contains information that is applicable to all instances of an alarm. It can be populated at start-up with all alarms that could happen on a system or later configured by a management application. It contains all the alarms for a given system. If a Notification is not represented in the alarmModelTable, it is not an alarm state transition. The alarmModelTable provides a

means of defining the raise/clear and other state transition relationships between alarm states. The alarmModelIndex acts as a unique identifier for an alarm. An alarm model consists of definitions of the possible states an alarm can assume as well as the Object Identifier (OID) of the Notification associated with this alarm state. The object alarmModelState defines the states of an alarm.

The alarmActiveTable contains a list of alarms that are currently occurring on a system. It is intended that this table be queried upon device discovery and rediscovery to determine which alarms are currently active on the device.

The alarmActiveVariableTable contains the Notification variable bindings associated with the alarms in the alarmActiveTable.

The alarmActiveStatsTable contains current and total raised alarm counts as well as the time of the last alarm raise and alarm clears per named alarm list.

The alarmClearTable contains recently cleared alarms. It contains up to alarmClearMaximum cleared alarms.

The MIB also defines generic alarm Notifications that can be used when there is not an existing applicable Notification to signal the alarm state transition - alarmActiveState and alarmClearState.

Extensibility

The relationship between the Alarm MIB and the other alarm model MIB modules is expressed by the following: The alarmModelTable has a corresponding table in the specific MIB. For each row in the specific MIB alarm model table there is one row in the alarmModelTable. The alarmActiveTable has a corresponding table in the specific MIBs. For each row in the specific MIB active alarm table, there is one row in the alarmActiveTable. The alarmModelSpecificPointer object in the alarmModelTable points to the specific model entry in an extended alarm model table corresponding to this particular alarm. The alarmActiveSpecificPointer object in the alarmActiveTable points to the specific active alarm entry in an extended active alarm table corresponding to this particular alarm instance.

Additional extensions can be defined by defining an AUGMENTATION of either the Alarm or ITU Alarm tables. As the alarm model table only provides a mechanism to point at one specific alarm model, additional specific models SHOULD define another mechanism to map from the generic alarm model to the additional model.

Problem Indication

The problem that each alarm indicates is identified through the Object Identifier of the NotificationId of the state transition, and, optionally, the ITU parameters. alarmModelDescription provides a description of the alarm state suitable for displaying to an operator.

Alarm State Transition Notification

The SNMP-TARGET-MIB RFC3413 provides the ability to specify which managers, if any, receive Notifications of problems. Solutions can therefore use the features of this MIB to change the Notification behaviour of their implementations. Specifying target hosts in this MIB along with specifying notifications in the alarmModelNotificationId would allow Notifications to be logged and sent out to management stations in an architecture as described in section 3.2. Specifying no target hosts in this MIB along with specifying notifications in the alarmModelNotificationId would allow Notifications to be logged but not sent out to management stations in an architecture as described in section 3.2. Regardless of what is defined in the SNMP-TARGET-MIB, specifying { 0 0 } in the alarmModelNotificationId would result in no notifications being logged or sent to management stations as a consequence of this particular alarm state transition.

Alarms are modelled by defining all possible states in the alarmModelTable, as well as defining alarmModelNotificationId, alarmModelVarbindIndex, and alarmModelVarbindValue for each of the possible alarm states. Optionally, ituAlarmPerceivedSeverity models the states in terms of ITU perceived severity.

Active Alarm Resource Identifier

Resources under alarm can be identified using the alarmActiveResourceId. This OBJECT IDENTIFIER points to an appropriate object to identify the given resource, depending on the type of the resource.

The consumer of the alarmActiveResourceId does not necessarily need to know the type of the resource in the resource ID, but if they want to know this, examining the content of the resource ID can derive it - 1.3.6.1.2.1.2.2.1.1.something is an interface, for example. It is therefore good practice to use resource IDs that can be consistently used across technologies, such as ifIndex, entPhysicalIndex or sysApplRunIndex, to minimize the number of resource prefixes a manager interested in a resource type needs to learn.

Resource ID can be calculated using the alarmModelResourcePrefix, alarmModelVarbindSubtree and the Notification varbinds. This allows for both the managed element to be able to compute and populate the alarmActiveResourceId object and for the manager to be able to determine when two separate alarm instances are referring to the same resource.

If alarmModelResourcePrefix has a value of 0.0, then alarmActiveResourceId is simply the variable identifier of the first Notification varbind that matches the prefix defined in alarmModelVarbindSubtree. Otherwise, alarmActiveResourceId is calculated by appending the instance information from the first Notification varbind that matches alarmModelVarbindSubtree to the prefix defined in alarmModelResourcePrefix. The instance information is the portion of the variable identifier following the part that matched alarmModelVarbindSubtree. If no match is found, then alarmActiveResourceId is simply the value of alarmModelResourcePrefix.

In addition to this, the variable bindings from the Notifications that signal the alarm state transitions are stored in the active alarm variable table. This allows for implementations familiar with the particular Notifications to implement other forms of resource identification.

For Example:

A) Consider an alarm modelled using the authenticationFailure RFC3418 Notification.

 authenticationFailure NOTIFICATION-TYPE
  STATUS  current
  DESCRIPTION
       "An authenticationFailure trap signifies that the SNMPv2
       entity, acting in an agent role, has received a protocol
       message that is not properly authenticated.  While all
       implementations of the SNMPv2 must be capable of generating
       this trap, the snmpEnableAuthenTraps object indicates
       whether this trap will be generated."
  ::= { snmpTraps 5 }
 To set the resource ID to be usmStats, 1.3.6.1.6.3.15.1.1,
 configure as follows:
      alarmModelVarbindSubtree = 0.0
      alarmModelResourcePrefix = usmStats (1.3.6.1.6.3.15.1.1)

B) Consider an alarm modelled using linkDown RFC2863

 linkDown NOTIFICATION-TYPE
         OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }
         STATUS  current
         DESCRIPTION
             ""
     ::= { snmpTraps 3 }
To set the resource Id to be the ifIndex, configure as follows:
      alarmModelVarbindSubtree = ifIndex (1.3.6.1.2.1.2.2.1.1)
      alarmModelResourcePrefix = 0.0
Alternatively, since ifIndex is the first varbind, the following
would also work, but might be less meaningful to a human reader
of the MIB table:
      alarmModelVarbindSubtree = 0.0
      alarmModelResourcePrefix = 0.0

C) Consider an alarm modelled using the bgpBackwardTransition RFC1657 Notification.

 bgpBackwardTransition NOTIFICATION-TYPE
         OBJECTS { bgpPeerLastError,
                      bgpPeerState      }
         STATUS  current
         DESCRIPTION
               "The BGPBackwardTransition Event is generated
               when the BGP FSM moves from a higher numbered
               state to a lower numbered state."
         ::= { bgpTraps 2 }
 To set the resource Id to be the bgpPeerRemoteAddr, the index to
 the bgpTable, where bgpPeerState resides, configure as follows:
      alarmModelVarbindSubtree = bgpPeerState
                                            (1.3.6.1.2.1.15.3.1.2)
      alarmModelResourcePrefix = bgpPeerRemoteAddr
        (1.3.6.1.2.1.15.3.1.7)

Configurable Alarm Models

The alarm model table SHOULD be initially populated by the system. The objects in alarmModelTable and ituAlarmTable have a MAX-ACCESS of read-create, which allows managers to modify the alarm models to suit their requirements.

Active Alarm Management

Lists of alarms currently active on an SNMP entity are stored in the alarmActiveTable and, optionally, a model specific alarmTable, e.g., the ituAlarmActiveTable.

Distributed Alarm Management

Distributed alarm management can be achieved by support of the Alarm MIB on both the alarm detection point and on the mid-level manager. This is facilitated by the ability to be able to store different named alarm lists. A mid-level manager could create an alarmListName for each of the devices it manages and therefore store separate lists for each device. In addition, the context and IP addresses of the alarm detection point are stored in the alarmActiveTable.

Definitions

ALARM-MIB DEFINITIONS ::= BEGIN

IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Unsigned32, Gauge32, TimeTicks, Counter32, Counter64, IpAddress, Opaque, mib-2, zeroDotZero

   FROM SNMPv2-SMI                 -- RFC2578

DateAndTime, RowStatus, RowPointer, TEXTUAL-CONVENTION

   FROM SNMPv2-TC                  -- RFC2579

SnmpAdminString

   FROM SNMP-FRAMEWORK-MIB         -- RFC3411

InetAddressType, InetAddress

   FROM INET-ADDRESS-MIB           -- RFC3291

MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP

   FROM SNMPv2-CONF                -- RFC2580

ZeroBasedCounter32

   FROM RMON2-MIB;                 -- RFC2021
 alarmMIB MODULE-IDENTITY
  LAST-UPDATED "200409090000Z"  -- September 09, 2004
  ORGANIZATION "IETF Distributed Management Working Group"
  CONTACT-INFO
       "WG EMail: [email protected]
       Subscribe: [email protected]
       http://www.ietf.org/html.charters/disman-charter.html
       Chair:     Randy Presuhn
                  [email protected]
       Editors:   Sharon Chisholm
                  Nortel Networks
                  PO Box 3511 Station C
                  Ottawa, Ont.  K1Y 4H7
                  Canada
                  [email protected]
                  Dan Romascanu
                  Avaya
                  Atidim Technology Park, Bldg. #3
                  Tel Aviv, 61131
                  Israel
                  Tel: +972-3-645-8414
                  Email: [email protected]"
  DESCRIPTION
       "The MIB module describes a generic solution
       to model alarms and to store the current list
       of active alarms.
       Copyright (C) The Internet Society (2004).  The
       initial version of this MIB module was published
       in RFC 3877.  For full legal notices see the RFC
       itself.  Supplementary information may be available on:
       http://www.ietf.org/copyrights/ianamib.html"
  REVISION    "200409090000Z"  -- September 09, 2004
  DESCRIPTION
      "Initial version, published as RFC 3877."
  ::= { mib-2 118 }

alarmObjects OBJECT IDENTIFIER ::= { alarmMIB 1 }

alarmNotifications OBJECT IDENTIFIER ::= { alarmMIB 0 }

alarmModel OBJECT IDENTIFIER ::= { alarmObjects 1 }

alarmActive OBJECT IDENTIFIER ::= { alarmObjects 2 }

alarmClear OBJECT IDENTIFIER ::= { alarmObjects 3 }

-- Textual Conventions

-- ResourceId is intended to be a general textual convention
-- that can be used outside of the set of MIBs related to
-- Alarm Management.

ResourceId ::= TEXTUAL-CONVENTION

STATUS current
DESCRIPTION
        "A unique identifier for this resource.
        The type of the resource can be determined by looking
        at the OID that describes the resource.
        Resources must be identified in a consistent manner.
        For example, if this resource is an interface, this
        object MUST point to an ifIndex and if this resource
        is a physical entity RFC2737, then this MUST point
        to an entPhysicalDescr, given that entPhysicalIndex
        is not accessible.  In general, the value is the
        name of the instance of the first accessible columnar
        object in the conceptual row of a table that is
        meaningful for this resource type, which SHOULD
        be defined in an IETF standard MIB."
SYNTAX         OBJECT IDENTIFIER
-- LocalSnmpEngineOrZeroLenStr is intended to be a general
-- textual convention that can be used outside of the set of
-- MIBs related to Alarm Management.
 LocalSnmpEngineOrZeroLenStr ::= TEXTUAL-CONVENTION
  STATUS current
  DESCRIPTION
      "An SNMP Engine ID or a zero-length string.  The
       instantiation of this textual convention will provide
       guidance on when this will be an SNMP Engine ID and
       when it will be a zero lengths string"
  SYNTAX         OCTET STRING (SIZE(0 | 5..32))

-- Alarm Model

alarmModelLastChanged OBJECT-TYPE

  SYNTAX      TimeTicks
  MAX-ACCESS  read-only
  STATUS      current
  DESCRIPTION
     "The value of sysUpTime at the time of the last
     creation, deletion or modification of an entry in
     the alarmModelTable.
     If the number and content of entries has been unchanged
     since the last re-initialization of the local network
     management subsystem, then the value of this object
     MUST be zero."
  ::= { alarmModel 1 }

alarmModelTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmModelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION

   "A table of information about possible alarms on the system,
    and how they have been modelled."
= { alarmModel 2 }

alarmModelEntry OBJECT-TYPE SYNTAX AlarmModelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION

   "Entries appear in this table for each possible alarm state.
   This table MUST be persistent across system reboots."

INDEX { alarmListName, alarmModelIndex, alarmModelState }

= { alarmModelTable 1 }

AlarmModelEntry ::= SEQUENCE { alarmModelIndex Unsigned32, alarmModelState Unsigned32, alarmModelNotificationId OBJECT IDENTIFIER, alarmModelVarbindIndex Unsigned32, alarmModelVarbindValue Integer32, alarmModelDescription SnmpAdminString, alarmModelSpecificPointer RowPointer, alarmModelVarbindSubtree OBJECT IDENTIFIER, alarmModelResourcePrefix OBJECT IDENTIFIER, alarmModelRowStatus RowStatus }

alarmModelIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION

   "An integer that acts as an alarm Id
   to uniquely identify each alarm
   within the named alarm list. "
= { alarmModelEntry 1 }

alarmModelState OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current

DESCRIPTION

    "A value of 1 MUST indicate a clear alarm state.
    The value of this object MUST be less than the
    alarmModelState of more severe alarm states for
    this alarm.  The value of this object MUST be more
    than the alarmModelState of less severe alarm states
    for this alarm."
::= { alarmModelEntry 2 }

alarmModelNotificationId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-create STATUS current DESCRIPTION

   "The NOTIFICATION-TYPE object identifier of this alarm
   state transition.  If there is no notification associated
   with this alarm state, the value of this object MUST be
   '0.0'"

DEFVAL { zeroDotZero }

= { alarmModelEntry 3 }

alarmModelVarbindIndex OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-create STATUS current DESCRIPTION

 "The index into the varbind listing of the notification
 indicated by alarmModelNotificationId which helps
 signal that the given alarm has changed state.
 If there is no applicable varbind, the value of this
 object MUST be zero.
 Note that the value of alarmModelVarbindIndex acknowledges
 the existence of the first two obligatory varbinds in
 the InformRequest-PDU and SNMPv2-Trap-PDU (sysUpTime.0
 and snmpTrapOID.0).  That is, a value of 2 refers to
 the snmpTrapOID.0.
 If the incoming notification is instead an SNMPv1 Trap-PDU,
 then an appropriate value for sysUpTime.0 or snmpTrapOID.0
 shall be determined by using the rules in section 3.1 of
 RFC3584"
 DEFVAL { 0 }
::= { alarmModelEntry 4 }

alarmModelVarbindValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-create

STATUS current DESCRIPTION

 "The value that the varbind indicated by
 alarmModelVarbindIndex takes to indicate
 that the alarm has entered this state.
 If alarmModelVarbindIndex has a value of 0, so
 MUST alarmModelVarbindValue.
 "
 DEFVAL { 0 }
::= { alarmModelEntry 5 }

alarmModelDescription OBJECT-TYPE

SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
  "A brief description of this alarm and state suitable
  to display to operators."

DEFVAL { "" }

= { alarmModelEntry 6 }

alarmModelSpecificPointer OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-create STATUS current DESCRIPTION

 "If no additional, model-specific Alarm MIB is supported by
  the system the value of this object is `0.0'and attempts
  to set it to any other value MUST be rejected appropriately.
  When a model-specific Alarm MIB is supported, this object
  MUST refer to the first accessible object in a corresponding
  row of the model definition in one of these model-specific
  MIB and attempts to set this object to { 0 0 } or any other
  value MUST be rejected appropriately."

DEFVAL { zeroDotZero }

= { alarmModelEntry 7 }
 alarmModelVarbindSubtree  OBJECT-TYPE
 SYNTAX  OBJECT IDENTIFIER
 MAX-ACCESS   read-create
 STATUS       current
 DESCRIPTION
   "The name portion of each VarBind in the notification,
    in order, is compared to the value of this object.
    If the name is equal to or a subtree of the value
    of this object, for purposes of computing the value
    of AlarmActiveResourceID the 'prefix' will be the
    matching portion, and the 'indexes' will be any
    remainder.  The examination of varbinds ends with
    the first match.  If the value of this object is 0.0,
    then the first varbind, or in the case of v2, the
    first varbind after the timestamp and the trap
    OID, will always be matched.
   "
  DEFVAL { zeroDotZero }
 ::= { alarmModelEntry 8 }
 alarmModelResourcePrefix  OBJECT-TYPE
 SYNTAX  OBJECT IDENTIFIER
 MAX-ACCESS   read-create
 STATUS       current
 DESCRIPTION
   "The value of AlarmActiveResourceId is computed
    by appending any indexes extracted in accordance
    with the description of alarmModelVarbindSubtree
    onto the value of this object.  If this object's
    value is 0.0, then the 'prefix' extracted is used
    instead.
   "
 DEFVAL { zeroDotZero }
 ::= { alarmModelEntry 9 }

alarmModelRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION

"Control for creating and deleting entries.  Entries may be
modified while active.  Alarms whose alarmModelRowStatus is
not active will not appear in either the alarmActiveTable
or the alarmClearTable.  Setting this object to notInService
cannot be used as an alarm suppression mechanism.  Entries
that are notInService will disappear as described in RFC2579.
This row can not be modified while it is being
referenced by a value of alarmActiveModelPointer.  In these
cases, an error of `inconsistentValue' will be returned to
the manager.
This entry may be deleted while it is being
referenced by a value of alarmActiveModelPointer.  This results
in the deletion of this entry and entries in the active alarms
referencing this entry via an alarmActiveModelPointer.
As all read-create objects in this table have a DEFVAL clause,
there is no requirement that any object be explicitly set
before this row can become active.  Note that a row consisting
only of default values is not very meaningful."
= { alarmModelEntry 10 }

-- Active Alarm Table --

alarmActiveLastChanged OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION

  "The value of sysUpTime at the time of the last
   creation or deletion of an entry in the alarmActiveTable.
   If the number of entries has been unchanged since the
   last re-initialization of the local network management
   subsystem, then this object contains a zero value."
= { alarmActive 1 }
alarmActiveOverflow  OBJECT-TYPE
 SYNTAX      Counter32
 UNITS       "active alarms"
 MAX-ACCESS  read-only
 STATUS      current
 DESCRIPTION
    "The number of active alarms that have not been put into
     the alarmActiveTable since system restart as a result
     of extreme resource constraints."
 ::= { alarmActive 5 }

alarmActiveTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmActiveEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION

   "A table of Active Alarms entries."
= { alarmActive 2 }

alarmActiveEntry OBJECT-TYPE SYNTAX AlarmActiveEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION

   "Entries appear in this table when alarms are raised.  They
    are removed when the alarm is cleared.
    If under extreme resource constraint the system is unable to
    add any more entries into this table, then the
    alarmActiveOverflow statistic will be increased by one."

INDEX { alarmListName, alarmActiveDateAndTime,

             alarmActiveIndex }
= { alarmActiveTable 1 }

AlarmActiveEntry ::= SEQUENCE { alarmListName SnmpAdminString, alarmActiveDateAndTime DateAndTime, alarmActiveIndex Unsigned32, alarmActiveEngineID LocalSnmpEngineOrZeroLenStr, alarmActiveEngineAddressType InetAddressType, alarmActiveEngineAddress InetAddress, alarmActiveContextName SnmpAdminString, alarmActiveVariables Unsigned32, alarmActiveNotificationID OBJECT IDENTIFIER, alarmActiveResourceId ResourceId, alarmActiveDescription SnmpAdminString, alarmActiveLogPointer RowPointer, alarmActiveModelPointer RowPointer, alarmActiveSpecificPointer RowPointer }

alarmListName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION

"The name of the list of alarms.  This SHOULD be the same as
nlmLogName if the Notification Log MIB RFC3014 is supported.
This SHOULD be the same as, or contain as a prefix, the
applicable snmpNotifyFilterProfileName if the
SNMP-NOTIFICATION-MIB DEFINITIONS RFC3413 is supported.
An implementation may allow multiple named alarm lists, up to
some implementation-specific limit (which may be none).  A
zero-length list name is reserved for creation and deletion
by the managed system, and MUST be used as the default log
name by systems that do not support named alarm lists."
= { alarmActiveEntry 1 }

alarmActiveDateAndTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS not-accessible STATUS current DESCRIPTION

   "The local date and time when the error occurred.
   This object facilitates retrieving all instances of
   alarms that have been raised or have changed state
   since a given point in time.
   Implementations MUST include the offset from UTC,
   if available.  Implementation in environments in which
   the UTC offset is not available is NOT RECOMMENDED."
= { alarmActiveEntry 2 }

alarmActiveIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION

   "A strictly monotonically increasing integer which
   acts as the index of entries within the named alarm
   list.  It wraps back to 1 after it reaches its
   maximum value."
= { alarmActiveEntry 3 }

alarmActiveEngineID OBJECT-TYPE SYNTAX LocalSnmpEngineOrZeroLenStr MAX-ACCESS read-only STATUS current DESCRIPTION

   "The identification of the SNMP engine at which the alarm
    originated.  If the alarm is from an SNMPv1 system this
    object is a zero length string."
= { alarmActiveEntry 4 }

alarmActiveEngineAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-only STATUS current DESCRIPTION

"This object indicates what type of address is stored in
the alarmActiveEngineAddress object - IPv4, IPv6, DNS, etc."
= { alarmActiveEntry 5 }

alarmActiveEngineAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION

"The address of the SNMP engine on which the alarm is
occurring.
This object MUST always be instantiated, even if the list
can contain alarms from only one engine."
= { alarmActiveEntry 6 }

alarmActiveContextName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION

   "The name of the SNMP MIB context from which the alarm came.
    For SNMPv1 alarms this is the community string from the Trap.
    Note that care MUST be taken when selecting community
    strings to ensure that these can be represented as a
    well-formed SnmpAdminString.  Community or Context names
    that are not well-formed SnmpAdminStrings will be mapped
    to zero length strings.
    If the alarm's source SNMP engine is known not to support
    multiple contexts, this object is a zero length string."
= { alarmActiveEntry 7 }

alarmActiveVariables OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION

   "The number of variables in alarmActiveVariableTable for this
   alarm."
= { alarmActiveEntry 8 }

alarmActiveNotificationID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION

   "The NOTIFICATION-TYPE object identifier of the alarm
   state transition that is occurring."
= { alarmActiveEntry 9 }

alarmActiveResourceId OBJECT-TYPE SYNTAX ResourceId MAX-ACCESS read-only STATUS current DESCRIPTION

  "This object identifies the resource under alarm.
  If there is no corresponding resource, then
  the value of this object MUST be 0.0."
= { alarmActiveEntry 10 }

alarmActiveDescription OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION

  "This object provides a textual description of the
  active alarm.  This text is generated dynamically by the
  notification generator to provide useful information
  to the human operator.  This information SHOULD
  provide information allowing the operator to locate
  the resource for which this alarm is being generated.
  This information is not intended for consumption by
  automated tools."
= { alarmActiveEntry 11 }

alarmActiveLogPointer OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION

   "A pointer to the corresponding row in a
   notification logging MIB where the state change
   notification for this active alarm is logged.
   If no log entry applies to this active alarm,
   then this object MUST have the value of 0.0"
= { alarmActiveEntry 12 }

alarmActiveModelPointer OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION

   "A pointer to the corresponding row in the
   alarmModelTable for this active alarm.  This
   points not only to the alarm model being
   instantiated, but also to the specific alarm
   state that is active."
= { alarmActiveEntry 13 }

alarmActiveSpecificPointer OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION

 "If no additional, model-specific, Alarm MIB is supported by
 the system this object is `0.0'.  When a model-specific Alarm
 MIB is supported, this object is the instance pointer to the
 specific model-specific active alarm list."
= { alarmActiveEntry 14 }

-- Active Alarm Variable Table --

alarmActiveVariableTable OBJECT-TYPE SYNTAX SEQUENCE OF AlarmActiveVariableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION

   "A table of variables to go with active alarm entries."
= { alarmActive 3 }

alarmActiveVariableEntry OBJECT-TYPE SYNTAX AlarmActiveVariableEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION

   "Entries appear in this table when there are variables in
   the varbind list of a corresponding alarm in
   alarmActiveTable.
   Entries appear in this table as though
   the trap/notification had been transported using a
   SNMPv2-Trap-PDU, as defined in RFC3416 - i.e., the
   alarmActiveVariableIndex 1 will always be sysUpTime
   and alarmActiveVariableIndex 2 will always be
   snmpTrapOID.
   If the incoming notification is instead an SNMPv1 Trap-PDU and
   the value of alarmModelVarbindIndex is 1 or 2, an appropriate
   value for sysUpTime.0 or snmpTrapOID.0 shall be determined
   by using the rules in section 3.1 of RFC3584."

INDEX { alarmListName, alarmActiveIndex,

          alarmActiveVariableIndex }
= { alarmActiveVariableTable 1 }

AlarmActiveVariableEntry ::= SEQUENCE { alarmActiveVariableIndex Unsigned32, alarmActiveVariableID OBJECT IDENTIFIER, alarmActiveVariableValueType INTEGER, alarmActiveVariableCounter32Val Counter32, alarmActiveVariableUnsigned32Val Unsigned32, alarmActiveVariableTimeTicksVal TimeTicks, alarmActiveVariableInteger32Val Integer32, alarmActiveVariableOctetStringVal OCTET STRING, alarmActiveVariableIpAddressVal IpAddress, alarmActiveVariableOidVal OBJECT IDENTIFIER, alarmActiveVariableCounter64Val Counter64,

alarmActiveVariableOpaqueVal Opaque }

alarmActiveVariableIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION

   "A strictly monotonically increasing integer, starting at
   1 for a given alarmActiveIndex, for indexing variables
   within the active alarm variable list. "
= { alarmActiveVariableEntry 1 }

alarmActiveVariableID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION

   "The alarm variable's object identifier."
= { alarmActiveVariableEntry 2 }

alarmActiveVariableValueType OBJECT-TYPE SYNTAX INTEGER {

     counter32(1),
     unsigned32(2),
     timeTicks(3),
     integer32(4),
     ipAddress(5),
     octetString(6),
     objectId(7),
     counter64(8),
     opaque(9)
     }

MAX-ACCESS read-only STATUS current DESCRIPTION

   "The type of the value.  One and only one of the value
   objects that follow is used for a given row in this table,
   based on this type."
= { alarmActiveVariableEntry 3 }

alarmActiveVariableCounter32Val OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION

   "The value when alarmActiveVariableType is 'counter32'."
= { alarmActiveVariableEntry 4 }

alarmActiveVariableUnsigned32Val OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION

   "The value when alarmActiveVariableType is 'unsigned32'."
= { alarmActiveVariableEntry 5 }

alarmActiveVariableTimeTicksVal OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION

   "The value when alarmActiveVariableType is 'timeTicks'."
= { alarmActiveVariableEntry 6 }

alarmActiveVariableInteger32Val OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION

   "The value when alarmActiveVariableType is 'integer32'."
= { alarmActiveVariableEntry 7 }

alarmActiveVariableOctetStringVal OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..65535)) MAX-ACCESS read-only STATUS current DESCRIPTION

   "The value when alarmActiveVariableType is 'octetString'."
= { alarmActiveVariableEntry 8 }

alarmActiveVariableIpAddressVal OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION

   "The value when alarmActiveVariableType is 'ipAddress'."
= { alarmActiveVariableEntry 9 }

alarmActiveVariableOidVal OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION

   "The value when alarmActiveVariableType is 'objectId'."
= { alarmActiveVariableEntry 10 }

alarmActiveVariableCounter64Val OBJECT-TYPE SYNTAX Counter64 MAX-ACCESS read-only STATUS current DESCRIPTION

   "The value when alarmActiveVariableType is 'counter64'."
= { alarmActiveVariableEntry 11 }

alarmActiveVariableOpaqueVal OBJECT-TYPE SYNTAX Opaque (SIZE(0..65535)) MAX-ACCESS read-only STATUS current DESCRIPTION

   "The value when alarmActiveVariableType is 'opaque'.
   Note that although RFC2578 RFC2578 forbids the use
   of Opaque in 'standard' MIB modules, this particular
   usage is driven by the need to be able to accurately
   represent any well-formed notification, and justified
   by the need for backward compatibility."
= { alarmActiveVariableEntry 12 }

-- Statistics --

alarmActiveStatsTable OBJECT-TYPE

  SYNTAX  SEQUENCE OF AlarmActiveStatsEntry
  MAX-ACCESS  not-accessible
  STATUS  current
  DESCRIPTION
     "This table represents the alarm statistics
     information."
 ::= { alarmActive 4 }

alarmActiveStatsEntry OBJECT-TYPE

  SYNTAX  AlarmActiveStatsEntry
  MAX-ACCESS  not-accessible
  STATUS  current
  DESCRIPTION
     "Statistics on the current active alarms."
  INDEX   { alarmListName }
 ::= {  alarmActiveStatsTable 1 }

AlarmActiveStatsEntry ::=

  SEQUENCE {
       alarmActiveStatsActiveCurrent  Gauge32,
       alarmActiveStatsActives        ZeroBasedCounter32,
       alarmActiveStatsLastRaise      TimeTicks,
       alarmActiveStatsLastClear      TimeTicks
            }

alarmActiveStatsActiveCurrent OBJECT-TYPE

  SYNTAX Gauge32
  MAX-ACCESS read-only
  STATUS  current
  DESCRIPTION
     "The total number of currently active alarms on the system."
   ::= { alarmActiveStatsEntry 1 }

alarmActiveStatsActives OBJECT-TYPE

  SYNTAX ZeroBasedCounter32
  MAX-ACCESS read-only
  STATUS  current
  DESCRIPTION
     "The total number of active alarms since system restarted."
   ::= { alarmActiveStatsEntry 2 }

alarmActiveStatsLastRaise OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION

  "The value of sysUpTime at the time of the last
   alarm raise for this alarm list.
   If no alarm raises have occurred since the
   last re-initialization of the local network management
   subsystem, then this object contains a zero value."
::= { alarmActiveStatsEntry 3 }

alarmActiveStatsLastClear OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION

  "The value of sysUpTime at the time of the last
   alarm clear for this alarm list.
   If no alarm clears have occurred since the
   last re-initialization of the local network management
   subsystem, then this object contains a zero value."
::= { alarmActiveStatsEntry 4 }

-- Alarm Clear

alarmClearMaximum OBJECT-TYPE

SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION

"This object specifies the maximum number of cleared alarms to store in the alarmClearTable. When this number is reached, the cleared alarms with the earliest clear time will be removed from the table."

::= { alarmClear 1 }

alarmClearTable OBJECT-TYPE

  SYNTAX  SEQUENCE OF AlarmClearEntry
  MAX-ACCESS  not-accessible
  STATUS  current
  DESCRIPTION
     "This table contains information on
     cleared alarms."
 ::= { alarmClear 2 }

alarmClearEntry OBJECT-TYPE

  SYNTAX  AlarmClearEntry
  MAX-ACCESS  not-accessible
  STATUS  current
  DESCRIPTION
     "Information on a cleared alarm."
  INDEX   { alarmListName, alarmClearDateAndTime,

alarmClearIndex }

 ::= {  alarmClearTable 1 }

AlarmClearEntry ::=

  SEQUENCE {

alarmClearIndex Unsigned32, alarmClearDateAndTime DateAndTime, alarmClearEngineID LocalSnmpEngineOrZeroLenStr, alarmClearEngineAddressType InetAddressType, alarmClearEngineAddress InetAddress, alarmClearContextName SnmpAdminString, alarmClearNotificationID OBJECT IDENTIFIER, alarmClearResourceId ResourceId, alarmClearLogIndex Unsigned32, alarmClearModelPointer RowPointer }

alarmClearIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION

   "An integer which acts as the index of entries within
   the named alarm list.  It wraps back to 1 after it
   reaches its maximum value.
   This object has the same value as the alarmActiveIndex that
   this alarm instance had when it was active."
= { alarmClearEntry 1 }

alarmClearDateAndTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS not-accessible STATUS current DESCRIPTION

   "The local date and time when the alarm cleared.
   This object facilitates retrieving all instances of
   alarms that have been cleared since a given point in time.
   Implementations MUST include the offset from UTC,
   if available.  Implementation in environments in which
   the UTC offset is not available is NOT RECOMMENDED."
= { alarmClearEntry 2 }

alarmClearEngineID OBJECT-TYPE SYNTAX LocalSnmpEngineOrZeroLenStr MAX-ACCESS read-only STATUS current DESCRIPTION

   "The identification of the SNMP engine at which the alarm
    originated.  If the alarm is from an SNMPv1 system this
    object is a zero length string."
= { alarmClearEntry 3 }

alarmClearEngineAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-only STATUS current DESCRIPTION

"This object indicates what type of address is stored in
the alarmActiveEngineAddress object - IPv4, IPv6, DNS, etc."
= { alarmClearEntry 4 }

alarmClearEngineAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION

"The Address of the SNMP engine on which the alarm was
occurring.  This is used to identify the source of an SNMPv1
trap, since an alarmActiveEngineId cannot be extracted from the
SNMPv1 trap PDU.
This object MUST always be instantiated, even if the list
can contain alarms from only one engine."
= { alarmClearEntry 5 }

alarmClearContextName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(0..32)) MAX-ACCESS read-only STATUS current DESCRIPTION

   "The name of the SNMP MIB context from which the alarm came.
   For SNMPv1 traps this is the community string from the Trap.
   Note that care needs to be taken when selecting community
   strings to ensure that these can be represented as a
   well-formed SnmpAdminString.  Community or Context names
   that are not well-formed SnmpAdminStrings will be mapped
   to zero length strings.
   If the alarm's source SNMP engine is known not to support
   multiple contexts, this object is a zero length string."
= { alarmClearEntry 6 }

alarmClearNotificationID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION

   "The NOTIFICATION-TYPE object identifier of the alarm
   clear."
= { alarmClearEntry 7 }

alarmClearResourceId OBJECT-TYPE SYNTAX ResourceId MAX-ACCESS read-only STATUS current DESCRIPTION

  "This object identifies the resource that was under alarm.
  If there is no corresponding resource, then
  the value of this object MUST be 0.0."
= { alarmClearEntry 8 }

alarmClearLogIndex OBJECT-TYPE SYNTAX Unsigned32 (0..4294967295) MAX-ACCESS read-only STATUS current

DESCRIPTION

   "This number MUST be the same as the log index of the
   applicable row in the notification log MIB, if it exists.
   If no log index applies to the trap, then this object
   MUST have the value of 0."
= { alarmClearEntry 9 }

alarmClearModelPointer OBJECT-TYPE SYNTAX RowPointer MAX-ACCESS read-only STATUS current DESCRIPTION

   "A pointer to the corresponding row in the
   alarmModelTable for this cleared alarm."
= { alarmClearEntry 10 }

-- Notifications

alarmActiveState NOTIFICATION-TYPE

OBJECTS     { alarmActiveModelPointer,
           alarmActiveResourceId }
STATUS      current
DESCRIPTION
"An instance of the alarm indicated by
alarmActiveModelPointer has been raised
against the entity indicated by
alarmActiveResourceId.
The agent must throttle the generation of
consecutive alarmActiveState traps so that there is at
least a two-second gap between traps of this
type against the same alarmActiveModelPointer and
alarmActiveResourceId.  When traps are throttled,
they are dropped, not queued for sending at a future time.
A management application should periodically check
the value of alarmActiveLastChanged to detect any
missed alarmActiveState notification-events, e.g.,
due to throttling or transmission loss."
::= { alarmNotifications 2 }

alarmClearState NOTIFICATION-TYPE OBJECTS { alarmActiveModelPointer,

             alarmActiveResourceId }

STATUS current DESCRIPTION

 "An instance of the alarm indicated by
 alarmActiveModelPointer has been cleared against
 the entity indicated by alarmActiveResourceId.
The agent must throttle the generation of
consecutive alarmActiveClear traps so that there is at
least a two-second gap between traps of this
type against the same alarmActiveModelPointer and
alarmActiveResourceId.  When traps are throttled,
they are dropped, not queued for sending at a future time.
A management application should periodically check
the value of alarmActiveLastChanged to detect any
missed alarmClearState notification-events, e.g.,
due to throttling or transmission loss."
= { alarmNotifications 3 }

-- Conformance

alarmConformance OBJECT IDENTIFIER ::= { alarmMIB 2 }

alarmCompliances OBJECT IDENTIFIER ::= { alarmConformance 1 }

alarmCompliance MODULE-COMPLIANCE

  STATUS  current
  DESCRIPTION
      "The compliance statement for systems supporting
      the Alarm MIB."
  MODULE -- this module
      MANDATORY-GROUPS {
       alarmActiveGroup,
       alarmModelGroup
      }
  GROUP       alarmActiveStatsGroup
   DESCRIPTION
       "This group is optional."
  GROUP       alarmClearGroup
   DESCRIPTION
       "This group is optional."
  GROUP       alarmNotificationsGroup
   DESCRIPTION
       "This group is optional."
= { alarmCompliances 1 }

alarmGroups OBJECT IDENTIFIER ::= { alarmConformance 2 }

alarmModelGroup OBJECT-GROUP OBJECTS {

   alarmModelLastChanged,
   alarmModelNotificationId,
   alarmModelVarbindIndex,
   alarmModelVarbindValue,
   alarmModelDescription,
   alarmModelSpecificPointer,
   alarmModelVarbindSubtree,
   alarmModelResourcePrefix,
   alarmModelRowStatus
  }
STATUS   current
DESCRIPTION
           "Alarm model group."
::= { alarmGroups 1}

alarmActiveGroup OBJECT-GROUP

    OBJECTS {
       alarmActiveLastChanged,
       alarmActiveOverflow,
       alarmActiveEngineID,
       alarmActiveEngineAddressType,
       alarmActiveEngineAddress,
       alarmActiveContextName,
       alarmActiveVariables,
       alarmActiveNotificationID,
       alarmActiveResourceId,
       alarmActiveDescription,
       alarmActiveLogPointer,
       alarmActiveModelPointer,
       alarmActiveSpecificPointer,
       alarmActiveVariableID,
       alarmActiveVariableValueType,
       alarmActiveVariableCounter32Val,
       alarmActiveVariableUnsigned32Val,
       alarmActiveVariableTimeTicksVal,
       alarmActiveVariableInteger32Val,
       alarmActiveVariableOctetStringVal,
       alarmActiveVariableIpAddressVal,
       alarmActiveVariableOidVal,
       alarmActiveVariableCounter64Val,
       alarmActiveVariableOpaqueVal
      }
      STATUS   current
      DESCRIPTION
           "Active Alarm list group."
      ::= { alarmGroups 2}
alarmActiveStatsGroup  OBJECT-GROUP
      OBJECTS  {
               alarmActiveStatsActives,
               alarmActiveStatsActiveCurrent,
               alarmActiveStatsLastRaise,
               alarmActiveStatsLastClear
                }
      STATUS   current
      DESCRIPTION
           "Active alarm summary group."
      ::= { alarmGroups 3}

alarmClearGroup OBJECT-GROUP

      OBJECTS  {

alarmClearMaximum, alarmClearEngineID, alarmClearEngineAddressType, alarmClearEngineAddress, alarmClearContextName, alarmClearNotificationID, alarmClearResourceId, alarmClearLogIndex, alarmClearModelPointer

                }
      STATUS   current
      DESCRIPTION
           "Cleared alarm group."
      ::= { alarmGroups 4}

alarmNotificationsGroup NOTIFICATION-GROUP NOTIFICATIONS { alarmActiveState, alarmClearState } STATUS current DESCRIPTION

       "The collection of notifications that can be used to
       model alarms for faults lacking pre-existing
       notification definitions."
= { alarmGroups 6 }

END

ITU Alarm

Overview

This MIB module defines alarm information specific to the alarm model defined in ITU M.3100 [M.3100], X.733 [X.733], and X.736 [X.736]. This MIB module follows the modular architecture defined by the Alarm MIB, in which the generic Alarm MIB can be augmented by other alarm information defined according to more specific models that define additional behaviour and characteristics.

The ituAlarmTable contains information from the ITU Alarm Model about possible alarms in the system.

The ituAlarmActiveTable contains information from the ITU Alarm Model about alarms modelled using the ituAlarmTable that are currently occurring on the system.

The ituAlarmActiveStatsTable provides statistics on current and total alarms.

IANA Considerations

Over time, there will be a need to add new IANAITUEventType and IANAItuProbableCause enumerated values. The Internet Assigned Number Authority (IANA) is responsible for the assignment of the enumerations in these TCs.

IANAItuProbableCause value of 0 is reserved for special purposes and MUST NOT be assigned. Values of IANAItuProbableCause in the range 1 to 1023 are reserved for causes that correspond to ITU-T probable cause. All other requests for new causes will be handled on a first-come basis, with 1025.

Request should come in the form of well-formed SMI RFC2578 for enumeration names that are unique and sufficiently descriptive.

While some effort will be taken to ensure that new enumerations do not conceptually duplicate existing enumerations it is acknowledged that the existence of conceptual duplicates in the starting probable cause list is an known industry reality.

To aid IANA in the administration of probable cause names and values, the OPS Area Director will appoint one or more experts to help review requests.

See http://www.iana.org

The following shall be used as the initial values, but the latest values for these textual conventions should be obtained from IANA:

IANA-ITU-ALARM-TC-MIB DEFINITIONS ::= BEGIN

IMPORTS MODULE-IDENTITY, mib-2

   FROM SNMPv2-SMI          -- RFC2578

TEXTUAL-CONVENTION

   FROM SNMPv2-TC;          -- RFC2579
ianaItuAlarmNumbers MODULE-IDENTITY
 LAST-UPDATED "200409090000Z"  -- September 09, 2004
 ORGANIZATION "IANA"
 CONTACT-INFO
     "Postal:    Internet Assigned Numbers Authority
                 Internet Corporation for Assigned Names
                 and Numbers
                 4676 Admiralty Way, Suite 330
                 Marina del Rey, CA 90292-6601
                 USA
     Tel:    +1  310-823-9358
     E-Mail: [email protected]"
 DESCRIPTION
     "The MIB module defines the ITU Alarm
     textual convention for objects expected to require
     regular extension.
     Copyright (C) The Internet Society (2004).  The
     initial version of this MIB module was published
     in RFC 3877.  For full legal notices see the RFC
     itself.  Supplementary information may be available on:
     http://www.ietf.org/copyrights/ianamib.html"
  REVISION    "200409090000Z"  -- September 09, 2004
  DESCRIPTION
      "Initial version, published as RFC 3877."
 ::= { mib-2 119 }

IANAItuProbableCause ::= TEXTUAL-CONVENTION

STATUS current
DESCRIPTION
    "ITU-T probable cause values.  Duplicate values defined in
     X.733 are appended with X733 to ensure syntactic uniqueness.
     Probable cause value 0 is reserved for special purposes.
     The Internet Assigned Number Authority (IANA) is responsible
     for the assignment of the enumerations in this TC.
     IANAItuProbableCause value of 0 is reserved for special
     purposes and MUST NOT be assigned.
     Values of IANAItuProbableCause in the range 1 to 1023 are
     reserved for causes that correspond to ITU-T probable cause.
     All other requests for new causes will be handled on a
     first-come, first served basis and will be assigned
     enumeration values starting with 1025.
     Request should  come in the form of well-formed
     SMI RFC2578 for enumeration names that are unique and
     sufficiently descriptive.
     While some effort will be taken to ensure that new probable
     causes do not conceptually duplicate existing probable
     causes it is acknowledged that the existence of conceptual
     duplicates in the starting probable cause list is an known
     industry reality.
     To aid IANA in the administration of probable cause names
     and values, the OPS Area Director will appoint one or more
     experts to help review requests.
     See http://www.iana.org"
REFERENCE
    "ITU Recommendation M.3100, 'Generic Network Information
        Model', 1995
     ITU Recommendation X.733, 'Information Technology - Open
        Systems Interconnection - System Management: Alarm
        Reporting Function', 1992
     ITU Recommendation X.736, 'Information Technology - Open
        Systems Interconnection - System Management: Security
        Alarm Reporting Function', 1992"
SYNTAX         INTEGER
        {
        -- The following probable causes were defined in M.3100
         aIS  (1),
         callSetUpFailure  (2),
         degradedSignal  (3),
         farEndReceiverFailure  (4),
         framingError  (5),
         lossOfFrame (6),
         lossOfPointer  (7),
         lossOfSignal  (8),
         payloadTypeMismatch (9),
         transmissionError (10),
         remoteAlarmInterface (11),
         excessiveBER  (12),
         pathTraceMismatch  (13),
         unavailable  (14),
         signalLabelMismatch (15),
         lossOfMultiFrame (16),
         receiveFailure (17),
         transmitFailure (18),
         modulationFailure (19),
         demodulationFailure (20),
         broadcastChannelFailure (21),
         connectionEstablishmentError (22),
         invalidMessageReceived (23),
         localNodeTransmissionError (24),
         remoteNodeTransmissionError (25),
         routingFailure (26),
--Values 27-50 are reserved for communications alarm related
--probable causes
-- The following are used with equipment alarm.
         backplaneFailure (51),
         dataSetProblem  (52),
         equipmentIdentifierDuplication  (53),
         externalIFDeviceProblem  (54),
         lineCardProblem (55),
         multiplexerProblem  (56),
         nEIdentifierDuplication  (57),
         powerProblem  (58),
         processorProblem  (59),
         protectionPathFailure  (60),
         receiverFailure  (61),
         replaceableUnitMissing  (62),
         replaceableUnitTypeMismatch (63),
         synchronizationSourceMismatch  (64),
         terminalProblem   (65),
         timingProblem   (66),
         transmitterFailure  (67),
         trunkCardProblem  (68),
         replaceableUnitProblem  (69),
         realTimeClockFailure (70),
--An equipment alarm to be issued if the system detects that the
--real time clock has failed
         antennaFailure (71),
         batteryChargingFailure (72),
         diskFailure (73),
         frequencyHoppingFailure (74),
         iODeviceError (75),
         lossOfSynchronisation (76),
         lossOfRedundancy (77),
         powerSupplyFailure (78),
         signalQualityEvaluationFailure (79),
         tranceiverFailure (80),
         protectionMechanismFailure (81),
         protectingResourceFailure (82),
-- Values 83-100 are reserved for equipment alarm related probable
-- causes
-- The following are used with environmental alarm.
         airCompressorFailure  (101),
         airConditioningFailure  (102),
         airDryerFailure   (103),
         batteryDischarging  (104),
         batteryFailure   (105),
         commercialPowerFailure  (106),
         coolingFanFailure  (107),
         engineFailure  (108),
         fireDetectorFailure  (109),
         fuseFailure  (110),
         generatorFailure  (111),
         lowBatteryThreshold (112),
         pumpFailure  (113),
         rectifierFailure  (114),
         rectifierHighVoltage  (115),
         rectifierLowFVoltage  (116),
         ventilationsSystemFailure  (117),
         enclosureDoorOpen  (118),
         explosiveGas  (119),
         fire (120),
         flood   (121),
         highHumidity  (122),
         highTemperature  (123),
         highWind  (124),
         iceBuildUp  (125),
         intrusionDetection  (126),
         lowFuel  (127),
         lowHumidity  (128),
         lowCablePressure  (129),
         lowTemperatue  (130),
         lowWater  (131),
         smoke  (132),
         toxicGas  (133),
         coolingSystemFailure (134),
         externalEquipmentFailure (135),
         externalPointFailure (136),
-- Values 137-150 are reserved for environmental alarm related
-- probable causes
-- The following are used with Processing error alarm.
         storageCapacityProblem (151),
         memoryMismatch  (152),
         corruptData  (153),
         outOfCPUCycles   (154),
         sfwrEnvironmentProblem  (155),
         sfwrDownloadFailure  (156),
         lossOfRealTimel (157),
--A processing error alarm to be issued after the system has
--reinitialised.  This will indicate
--to the management systems that the view they have of the managed
--system may no longer
--be valid.  Usage example: The managed
--system issues this alarm after a reinitialization with severity
--warning to inform the
--management system about the event.  No clearing notification will
--be sent.
         applicationSubsystemFailure (158),
         configurationOrCustomisationError (159),
         databaseInconsistency (160),
         fileError (161),
         outOfMemory (162),
         softwareError (163),
         timeoutExpired (164),
         underlayingResourceUnavailable (165),
         versionMismatch (166),
--Values 168-200 are reserved for processing error alarm related
-- probable causes.
         bandwidthReduced (201),
         congestion (202),
         excessiveErrorRate (203),
         excessiveResponseTime (204),
         excessiveRetransmissionRate (205),
         reducedLoggingCapability (206),
         systemResourcesOverload (207 ),
         -- The following were defined X.733
         adapterError (500),
         applicationSubsystemFailture (501),
         bandwidthReducedX733 (502),
         callEstablishmentError (503),
         communicationsProtocolError (504),
         communicationsSubsystemFailure (505),
         configurationOrCustomizationError (506),
         congestionX733 (507),
         coruptData (508),
         cpuCyclesLimitExceeded (509),
         dataSetOrModemError (510),
         degradedSignalX733 (511),
         dteDceInterfaceError (512),
         enclosureDoorOpenX733 (513),
         equipmentMalfunction (514),
         excessiveVibration (515),
         fileErrorX733 (516),
         fireDetected (517),
         framingErrorX733 (518),
         heatingVentCoolingSystemProblem (519),
         humidityUnacceptable (520),
         inputOutputDeviceError (521),
         inputDeviceError (522),
         lanError (523),
         leakDetected (524),
         localNodeTransmissionErrorX733 (525),
         lossOfFrameX733 (526),
         lossOfSignalX733 (527),
         materialSupplyExhausted (528),
         multiplexerProblemX733 (529),
         outOfMemoryX733 (530),
         ouputDeviceError (531),
         performanceDegraded (532),
         powerProblems (533),
         pressureUnacceptable (534),
         processorProblems (535),
         pumpFailureX733 (536),
         queueSizeExceeded (537),
         receiveFailureX733 (538),
         receiverFailureX733 (539),
         remoteNodeTransmissionErrorX733 (540),
         resourceAtOrNearingCapacity (541),
         responseTimeExecessive (542),
         retransmissionRateExcessive (543),
         softwareErrorX733 (544),
         softwareProgramAbnormallyTerminated (545),
         softwareProgramError (546),
         storageCapacityProblemX733 (547),
         temperatureUnacceptable (548),
         thresholdCrossed (549),
         timingProblemX733 (550),
         toxicLeakDetected (551),
         transmitFailureX733 (552),
         transmiterFailure (553),
         underlyingResourceUnavailable (554),
         versionMismatchX733 (555),
         -- The following are defined in X.736
         authenticationFailure (600),
         breachOfConfidentiality (601),
         cableTamper (602),
         delayedInformation (603),
         denialOfService (604),
         duplicateInformation (605),
         informationMissing (606),
         informationModificationDetected (607),
         informationOutOfSequence (608),
         keyExpired (609),
         nonRepudiationFailure (610),
         outOfHoursActivity (611),
         outOfService (612),
         proceduralError (613),
         unauthorizedAccessAttempt (614),
         unexpectedInformation (615),
         other (1024)
         }

IANAItuEventType ::= TEXTUAL-CONVENTION

STATUS current
DESCRIPTION
        "The ITU event Type values.
        The Internet Assigned Number Authority (IANA) is
        responsible for the assignment of the enumerations
        in this TC.
        Request should  come in the form of well-formed
        SMI RFC2578 for enumeration names that are unique
        and sufficiently descriptive.
        See http://www.iana.org "
REFERENCE
       "ITU Recommendation X.736, 'Information Technology - Open
        Systems Interconnection - System Management: Security
        Alarm Reporting Function', 1992"
SYNTAX         INTEGER
       {
       other (1),
       communicationsAlarm (2),
       qualityOfServiceAlarm (3),
       processingErrorAlarm (4),
       equipmentAlarm (5),
       environmentalAlarm (6),
       integrityViolation (7),
       operationalViolation (8),
       physicalViolation (9),
       securityServiceOrMechanismViolation (10),
       timeDomainViolation (11)
       }

END

Textual Conventions

ITU-ALARM-TC-MIB DEFINITIONS ::= BEGIN

IMPORTS MODULE-IDENTITY, mib-2

   FROM SNMPv2-SMI         -- RFC2578

TEXTUAL-CONVENTION

   FROM SNMPv2-TC;         -- RFC2579
 ituAlarmTc MODULE-IDENTITY
  LAST-UPDATED "200409090000Z"  -- September 09, 2004
  ORGANIZATION "IETF Distributed Management Working Group"
  CONTACT-INFO
     " WG EMail: [email protected]
       Subscribe: [email protected]
       http://www.ietf.org/html.charters/disman-charter.html
       Chair:     Randy Presuhn
                  [email protected]
       Editors:   Sharon Chisholm
                  Nortel Networks
                  PO Box 3511 Station C
                  Ottawa, Ont.  K1Y 4H7
                  Canada
                  [email protected]
                  Dan Romascanu
                  Avaya
                  Atidim Technology Park, Bldg. #3
                  Tel Aviv, 61131
                  Israel
                  Tel: +972-3-645-8414
                  Email: [email protected]"
  DESCRIPTION
     "This MIB module defines the ITU Alarm
     textual convention for objects not expected to require
     regular extension.
     Copyright (C) The Internet Society (2004).  The
     initial version of this MIB module was published
     in RFC 3877.  For full legal notices see the RFC
     itself.  Supplementary information may be available on:
     http://www.ietf.org/copyrights/ianamib.html"
  REVISION    "200409090000Z"  -- September 09, 2004
  DESCRIPTION
      "Initial version, published as RFC 3877."
 ::= { mib-2 120 }

ItuPerceivedSeverity ::= TEXTUAL-CONVENTION

STATUS current
DESCRIPTION
        "ITU perceived severity values"
REFERENCE
       "ITU Recommendation M.3100, 'Generic Network Information
        Model', 1995
        ITU Recommendation X.733, 'Information Technology - Open
        Systems Interconnection - System Management: Alarm
        Reporting Function', 1992"
SYNTAX         INTEGER
       {
       cleared (1),
       indeterminate (2),
       critical (3),
       major (4),
       minor (5),
       warning (6)
       }

ItuTrendIndication ::= TEXTUAL-CONVENTION

STATUS current
DESCRIPTION
        "ITU trend indication values for alarms."
REFERENCE
       "ITU Recommendation M.3100, 'Generic Network Information
        Model', 1995
        ITU Recommendation X.733, 'Information Technology - Open
        Systems Interconnection - System Management: Alarm
        Reporting Function', 1992"
SYNTAX         INTEGER
  {
  moreSevere (1),
  noChange (2),
  lessSevere (3)
  }

END

Definitions

ITU-ALARM-MIB DEFINITIONS ::= BEGIN

IMPORTS

  MODULE-IDENTITY, OBJECT-TYPE,
  Gauge32, mib-2
      FROM SNMPv2-SMI                -- RFC2578
  AutonomousType, RowPointer
      FROM SNMPv2-TC                 -- RFC2579
  SnmpAdminString
      FROM SNMP-FRAMEWORK-MIB        -- RFC3411
  alarmListName, alarmModelIndex,
  alarmActiveDateAndTime, alarmActiveIndex
      FROM ALARM-MIB                 -- RFC3877
  ItuPerceivedSeverity,
  ItuTrendIndication
      FROM ITU-ALARM-TC-MIB          -- RFC3877
  IANAItuProbableCause,
  IANAItuEventType
      FROM IANA-ITU-ALARM-TC-MIB     -- RFC3877
  MODULE-COMPLIANCE, OBJECT-GROUP
      FROM SNMPv2-CONF               -- RFC2580
  ZeroBasedCounter32
      FROM RMON2-MIB;                -- RFC2021
 ituAlarmMIB MODULE-IDENTITY
     LAST-UPDATED "200409090000Z"  -- September 09, 2004
     ORGANIZATION "IETF Distributed Management Working Group"
     CONTACT-INFO
          "WG EMail: [email protected]
          Subscribe: [email protected]
          http://www.ietf.org/html.charters/disman-charter.html
          Chair:     Randy Presuhn
                     [email protected]
          Editors:   Sharon Chisholm
                     Nortel Networks
                     PO Box 3511 Station C
                     Ottawa, Ont.  K1Y 4H7
                     Canada
                     [email protected]
                     Dan Romascanu
                     Avaya
                     Atidim Technology Park, Bldg. #3
                     Tel Aviv, 61131
                     Israel
                     Tel: +972-3-645-8414
                     Email: [email protected]"
     DESCRIPTION
             "The MIB module describes ITU Alarm information
             as defined in ITU Recommendation M.3100 [M.3100],
             X.733 [X.733] and X.736 [X.736].
             Copyright (C) The Internet Society (2004).  The
             initial version of this MIB module was published
             in RFC 3877.  For full legal notices see the RFC
             itself.  Supplementary information may be available on:
             http://www.ietf.org/copyrights/ianamib.html"
     REVISION    "200409090000Z"  -- September 09, 2004
     DESCRIPTION
         "Initial version, published as RFC 3877."
     ::= { mib-2 121 }

ituAlarmObjects OBJECT IDENTIFIER ::= { ituAlarmMIB 1 }

ituAlarmModel OBJECT IDENTIFIER ::= { ituAlarmObjects 1 }

ituAlarmActive OBJECT IDENTIFIER ::= { ituAlarmObjects 2 }

ituAlarmTable OBJECT-TYPE

  SYNTAX      SEQUENCE OF ItuAlarmEntry
  MAX-ACCESS  not-accessible
  STATUS      current
  DESCRIPTION
      "A table of ITU Alarm information for possible alarms
      on the system."
  ::= { ituAlarmModel 1 }

ituAlarmEntry OBJECT-TYPE

  SYNTAX      ItuAlarmEntry
  MAX-ACCESS  not-accessible
  STATUS      current
  DESCRIPTION
      "Entries appear in this table whenever an entry is created
       in the alarmModelTable with a value of alarmModelState in
       the range from 1 to 6.  Entries disappear from this table
       whenever the corresponding entries are deleted from the
       alarmModelTable, including in cases where those entries
       have been deleted due to local system action.  The value of
       alarmModelSpecificPointer has no effect on the creation
       or deletion of entries in this table.  Values of
       alarmModelState map to values of ituAlarmPerceivedSeverity
       as follows:
         alarmModelState -> ituAlarmPerceivedSeverity
                1        ->         clear (1)
                2        ->         indeterminate (2)
                3        ->         warning (6)
                4        ->         minor (5)
                5        ->         major (4)
                6        ->         critical (3)
       All other values of alarmModelState MUST NOT appear
       in this table.
       This table MUST be persistent across system reboots."
  INDEX       { alarmListName, alarmModelIndex,
               ituAlarmPerceivedSeverity }
  ::= { ituAlarmTable 1 }

ItuAlarmEntry ::= SEQUENCE {

  ituAlarmPerceivedSeverity     ItuPerceivedSeverity,
  ituAlarmEventType             IANAItuEventType,
  ituAlarmProbableCause         IANAItuProbableCause,
  ituAlarmAdditionalText        SnmpAdminString,
  ituAlarmGenericModel          RowPointer }

ituAlarmPerceivedSeverity OBJECT-TYPE

  SYNTAX  ItuPerceivedSeverity
  MAX-ACCESS   not-accessible
  STATUS       current
  DESCRIPTION
           "ITU perceived severity values."
   REFERENCE
       "ITU Recommendation M.3100, 'Generic Network Information
           Model', 1995
        ITU Recommendation X.733, 'Information Technology - Open
           Systems Interconnection - System Management: Alarm
           Reporting Function', 1992"
   ::= { ituAlarmEntry 1 }

ituAlarmEventType OBJECT-TYPE

  SYNTAX       IANAItuEventType
  MAX-ACCESS   read-write
  STATUS       current
  DESCRIPTION
           "Represents the event type values for the alarms"
   REFERENCE
       "ITU Recommendation M.3100, 'Generic Network Information
           Model', 1995
        ITU Recommendation X.733, 'Information Technology - Open
           Systems Interconnection - System Management: Alarm
           Reporting Function', 1992
        ITU Recommendation X.736, 'Information Technology - Open
           Systems Interconnection - System Management: Security
           Alarm Reporting Function', 1992"
   ::= { ituAlarmEntry 2 }

ituAlarmProbableCause OBJECT-TYPE

  SYNTAX      IANAItuProbableCause
  MAX-ACCESS  read-write
  STATUS       current
  DESCRIPTION
           "ITU probable cause values."
   REFERENCE
       "ITU Recommendation M.3100, 'Generic Network Information
           Model', 1995
        ITU Recommendation X.733, 'Information Technology - Open
           Systems Interconnection - System Management: Alarm
           Reporting Function', 1992
        ITU Recommendation X.736, 'Information Technology - Open
           Systems Interconnection - System Management: Security
           Alarm Reporting Function', 1992"
   ::= { ituAlarmEntry 3 }

ituAlarmAdditionalText OBJECT-TYPE

  SYNTAX  SnmpAdminString
  MAX-ACCESS read-write
  STATUS     current
  DESCRIPTION
           "Represents the additional text field for the alarm."
   REFERENCE
       "ITU Recommendation M.3100, 'Generic Network Information
           Model', 1995
        ITU Recommendation X.733, 'Information Technology - Open
           Systems Interconnection - System Management: Alarm
           Reporting Function', 1992"
   ::= { ituAlarmEntry 4}

ituAlarmGenericModel OBJECT-TYPE

  SYNTAX     RowPointer
  MAX-ACCESS read-write
  STATUS     current
  DESCRIPTION
  "This object points to the corresponding
   row in the alarmModelTable for this alarm severity.
   This corresponding entry to alarmModelTable could also
   be derived by performing the reverse of the mapping
   from alarmModelState to ituAlarmPerceivedSeverity defined
   in the description of ituAlarmEntry to determine the
   appropriate { alarmListName, alarmModelIndex, alarmModelState }
   for this { alarmListName, alarmModelIndex,
   ituAlarmPerceivedSeverity }."
  ::= { ituAlarmEntry 5 }

-- ITU Active Alarm Table --

ituAlarmActiveTable OBJECT-TYPE

  SYNTAX      SEQUENCE OF ItuAlarmActiveEntry
  MAX-ACCESS  not-accessible
  STATUS      current
  DESCRIPTION
      "A table of ITU information for active alarms entries."
  ::= { ituAlarmActive 1 }

ituAlarmActiveEntry OBJECT-TYPE

  SYNTAX      ItuAlarmActiveEntry
  MAX-ACCESS  not-accessible
  STATUS      current
  DESCRIPTION
      "Entries appear in this table when alarms are active.  They
      are removed when the alarm is no longer occurring."
  INDEX       { alarmListName, alarmActiveDateAndTime,
               alarmActiveIndex }
  ::= { ituAlarmActiveTable 1 }

ItuAlarmActiveEntry ::= SEQUENCE {

   ituAlarmActiveTrendIndication       ItuTrendIndication,
   ituAlarmActiveDetector              AutonomousType,
   ituAlarmActiveServiceProvider       AutonomousType,
   ituAlarmActiveServiceUser           AutonomousType
   }

ituAlarmActiveTrendIndication OBJECT-TYPE

  SYNTAX      ItuTrendIndication
  MAX-ACCESS  read-only
  STATUS       current
  DESCRIPTION
           "Represents the trend indication values for the alarms."
   REFERENCE
       "ITU Recommendation M.3100, 'Generic Network Information
           Model', 1995
        ITU Recommendation X.733, 'Information Technology - Open
           Systems Interconnection - System Management: Alarm
           Reporting Function', 1992"
   ::= { ituAlarmActiveEntry 1 }

ituAlarmActiveDetector OBJECT-TYPE

  SYNTAX AutonomousType
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
     "Represents the SecurityAlarmDetector object."
   REFERENCE
       "ITU Recommendation X.736, 'Information Technology - Open
           Systems Interconnection - System Management: Security
           Alarm Reporting Function', 1992"
  ::= { ituAlarmActiveEntry 2 }

ituAlarmActiveServiceProvider OBJECT-TYPE

  SYNTAX AutonomousType
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
     "Represents the ServiceProvider object."
   REFERENCE
       "ITU Recommendation X.736, 'Information Technology - Open
           Systems Interconnection - System Management: Security
           Alarm Reporting Function', 1992"
  ::= { ituAlarmActiveEntry 3 }

ituAlarmActiveServiceUser OBJECT-TYPE

  SYNTAX AutonomousType
  MAX-ACCESS read-only
  STATUS current
  DESCRIPTION
     "Represents the ServiceUser object."
   REFERENCE
       "ITU Recommendation X.736, 'Information Technology - Open
           Systems Interconnection - System Management: Security
           Alarm Reporting Function', 1992"
  ::= { ituAlarmActiveEntry 4 }

-- Statistics and Counters

ituAlarmActiveStatsTable OBJECT-TYPE

     SYNTAX  SEQUENCE OF ItuAlarmActiveStatsEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
        "This table represents the ITU alarm statistics
        information."
 ::= { ituAlarmActive 2 }

ituAlarmActiveStatsEntry OBJECT-TYPE

     SYNTAX  ItuAlarmActiveStatsEntry
     MAX-ACCESS  not-accessible
     STATUS  current
     DESCRIPTION
        "Statistics on the current active ITU alarms."
     INDEX   { alarmListName }
 ::= {  ituAlarmActiveStatsTable 1 }

ItuAlarmActiveStatsEntry ::=

SEQUENCE {
  ituAlarmActiveStatsIndeterminateCurrent Gauge32,
  ituAlarmActiveStatsCriticalCurrent      Gauge32,
  ituAlarmActiveStatsMajorCurrent         Gauge32,
  ituAlarmActiveStatsMinorCurrent         Gauge32,
  ituAlarmActiveStatsWarningCurrent       Gauge32,
  ituAlarmActiveStatsIndeterminates       ZeroBasedCounter32,
  ituAlarmActiveStatsCriticals            ZeroBasedCounter32,
  ituAlarmActiveStatsMajors               ZeroBasedCounter32,
  ituAlarmActiveStatsMinors               ZeroBasedCounter32,
  ituAlarmActiveStatsWarnings             ZeroBasedCounter32
}

ituAlarmActiveStatsIndeterminateCurrent OBJECT-TYPE

  SYNTAX      Gauge32
  MAX-ACCESS  read-only
  STATUS      current
  DESCRIPTION
      "A count of the current number of active alarms with a
       ituAlarmPerceivedSeverity of indeterminate."
  ::= { ituAlarmActiveStatsEntry 1 }

ituAlarmActiveStatsCriticalCurrent OBJECT-TYPE

  SYNTAX      Gauge32
  MAX-ACCESS  read-only
  STATUS      current
  DESCRIPTION
      "A count of the current number of active alarms with a
       ituAlarmPerceivedSeverity of critical."
  ::= { ituAlarmActiveStatsEntry 2 }

ituAlarmActiveStatsMajorCurrent OBJECT-TYPE

  SYNTAX      Gauge32
  MAX-ACCESS  read-only
  STATUS      current
  DESCRIPTION
      "A count of the current number of active alarms with a
       ituAlarmPerceivedSeverity of major."
  ::= { ituAlarmActiveStatsEntry 3 }

ituAlarmActiveStatsMinorCurrent OBJECT-TYPE

  SYNTAX      Gauge32
  MAX-ACCESS  read-only
  STATUS      current
  DESCRIPTION
      "A count of the current number of active alarms with a
       ituAlarmPerceivedSeverity of minor."
  ::= { ituAlarmActiveStatsEntry 4 }

ituAlarmActiveStatsWarningCurrent OBJECT-TYPE

  SYNTAX      Gauge32
  MAX-ACCESS  read-only
  STATUS      current
  DESCRIPTION
      "A count of the current number of active alarms with a
       ituAlarmPerceivedSeverity of warning."
  ::= { ituAlarmActiveStatsEntry 5 }

ituAlarmActiveStatsIndeterminates OBJECT-TYPE

  SYNTAX      ZeroBasedCounter32
  MAX-ACCESS  read-only
  STATUS      current
  DESCRIPTION
      "A count of the total number of active alarms with a
       ituAlarmPerceivedSeverity of indeterminate since system
       restart."
  ::= { ituAlarmActiveStatsEntry 6 }

ituAlarmActiveStatsCriticals OBJECT-TYPE

  SYNTAX      ZeroBasedCounter32
  MAX-ACCESS  read-only
  STATUS      current
  DESCRIPTION
      "A count of the total number of active alarms with a
       ituAlarmPerceivedSeverity of critical since system restart."
  ::= { ituAlarmActiveStatsEntry 7 }

ituAlarmActiveStatsMajors OBJECT-TYPE

  SYNTAX      ZeroBasedCounter32
  MAX-ACCESS  read-only
  STATUS      current
  DESCRIPTION
      "A count of the total number of active alarms with a
       ituAlarmPerceivedSeverity of major since system restart."
  ::= { ituAlarmActiveStatsEntry 8 }

ituAlarmActiveStatsMinors OBJECT-TYPE

  SYNTAX      ZeroBasedCounter32
  MAX-ACCESS  read-only
  STATUS      current
  DESCRIPTION
      "A count of the total number of active alarms with a
       ituAlarmPerceivedSeverity of minor since system restart."
  ::= { ituAlarmActiveStatsEntry 9 }

ituAlarmActiveStatsWarnings OBJECT-TYPE

  SYNTAX      ZeroBasedCounter32
  MAX-ACCESS  read-only
  STATUS      current
  DESCRIPTION
      "A count of the total number of active alarms with a
       ituAlarmPerceivedSeverity of warning since system restart."
  ::= { ituAlarmActiveStatsEntry 10 }

-- Conformance

ituAlarmConformance OBJECT IDENTIFIER ::= { ituAlarmMIB 2 } ituAlarmCompliances OBJECT IDENTIFIER ::= { ituAlarmConformance 1 }

ituAlarmCompliance MODULE-COMPLIANCE

  STATUS  current
  DESCRIPTION
         "The compliance statement for systems supporting
         the ITU Alarm MIB."
  MODULE -- this module
      MANDATORY-GROUPS {
          ituAlarmGroup
          }
  GROUP       ituAlarmServiceUserGroup
      DESCRIPTION
          "This group is optional."
  GROUP       ituAlarmSecurityGroup
      DESCRIPTION
          "This group is optional."
  GROUP       ituAlarmStatisticsGroup
      DESCRIPTION
          "This group is optional."
 ::= { ituAlarmCompliances 1 }

ituAlarmGroups OBJECT IDENTIFIER ::= { ituAlarmConformance 2 }

ituAlarmGroup OBJECT-GROUP

OBJECTS {
          ituAlarmEventType,
          ituAlarmProbableCause,
          ituAlarmGenericModel
        }
STATUS   current
DESCRIPTION
              "ITU alarm details list group."
::= { ituAlarmGroups 1}

ituAlarmServiceUserGroup OBJECT-GROUP

OBJECTS {
          ituAlarmAdditionalText,
          ituAlarmActiveTrendIndication
        }
STATUS current
DESCRIPTION
        "The use of these parameters is a service-user option."
::= { ituAlarmGroups 2 }

ituAlarmSecurityGroup OBJECT-GROUP

 OBJECTS {
         ituAlarmActiveDetector,
         ituAlarmActiveServiceProvider,
         ituAlarmActiveServiceUser
        }
 STATUS current
 DESCRIPTION
        "Security Alarm Reporting Function"
   REFERENCE
       "ITU Recommendation X.736, 'Information Technology - Open
           Systems Interconnection - System Management: Security
           Alarm Reporting Function', 1992"
 ::= { ituAlarmGroups 3 }

ituAlarmStatisticsGroup OBJECT-GROUP

 OBJECTS {
        ituAlarmActiveStatsIndeterminateCurrent,
        ituAlarmActiveStatsCriticalCurrent,
        ituAlarmActiveStatsMajorCurrent,
        ituAlarmActiveStatsMinorCurrent,
        ituAlarmActiveStatsWarningCurrent,
        ituAlarmActiveStatsIndeterminates,
        ituAlarmActiveStatsCriticals,
        ituAlarmActiveStatsMajors,
        ituAlarmActiveStatsMinors,
        ituAlarmActiveStatsWarnings
         }
 STATUS current
 DESCRIPTION
   "ITU Active Alarm Statistics."
 ::= { ituAlarmGroups 4 }

END

Examples

Alarms Based on linkUp/linkDown Notifications

This example demonstrates an interface-based alarm that goes into a state of "warning" when a linkDown Notification RFC2863 occurs but the ifAdminStatus indicates the interface was taken down administratively. If IfAdminStatus is "up" when the linkDown Notification occurs, then there is a problem, so the state of the alarm is critical. A linkUp alarm clears the alarm.

linkDown NOTIFICATION-TYPE

    OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }
    STATUS  current
    DESCRIPTION
        ""
::= { snmpTraps 3 }

linkUp NOTIFICATION-TYPE

    OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }
    STATUS  current
    DESCRIPTION
        ""
::= { snmpTraps 4 }
alarmModelIndex                  3
alarmModelState                  1
alarmModelNotificationId         linkUp
alarmModelVarbindIndex           0
alarmModelVarbindValue           0
alarmModelDescription            "linkUp"
alarmModelSpecificPointer        ituAlarmEntry.3.1
alarmModelVarbindSubtree         ifIndex (1.3.6.1.2.1.2.2.1.1)
alarmModelResourcePrefix         0.0
alarmModelRowStatus              active (1)
ituAlarmEventType                communicationsAlarm (2)
ituAlarmPerceivedSeverity        cleared (1)
ituAlarmGenericModel             alarmModelEntry.3.1
alarmModelIndex                  3
alarmModelState                  2
alarmModelNotificationId         linkDown
alarmModelVarbindIndex           2
alarmModelVarbindValue           down (2)
alarmModelDescription            "linkDown administratively"
alarmModelSpecificPointer        ituAlarmEntry.3.6
alarmModelVarbindSubtree         ifIndex (1.3.6.1.2.1.2.2.1.1)
alarmModelResourcePrefix         0.0
alarmModelRowStatus              active (1)
ituAlarmEventType                communicationsAlarm (2)
ituAlarmPerceivedSeverity        warning (6)
ituAlarmGenericModel             alarmModelEntry.3.2
alarmModelIndex                  3
alarmModelState                  3
alarmModelNotificationId         linkDown
alarmModelVarbindIndex           2
alarmModelVarbindValue           up (1)
alarmModelDescription            "linkDown - confirmed problem"
alarmModelSpecificPointer        ituAlarmEntry.3.3
alarmModelVarbindSubtree         ifIndex (1.3.6.1.2.1.2.2.1.1)
alarmModelResourcePrefix         0.0
alarmModelRowStatus              active (1)
ituAlarmEventType                communicationsAlarm (2)
ituAlarmPerceivedSeverity        critical (3)
ituAlarmGenericModel             alarmModelEntry.3.3
alarmActiveIndex                 1
alarmActiveDateAndTime           2342464573
alarmActiveDateAndTime           DateAndTime,
alarmActiveEngineID              SnmpEngineID,
alarmActiveEngineAddressType     ipV4
alarmActiveEngineAddress         10.10.10.10
alarmActiveContextName           SnmpAdminString,
alarmActiveVariables             3
alarmActiveNotificationID        1.3.6.1.6.3.1.1.5.3
alarmActiveResourceId            1.3.6.1.2.1.2.2.1.1.346
alarmActiveLogPointer            0.0
alarmActiveModelPointer          alarmModelEntry.3.3
alarmActiveSpecificPointer       ituAlarmActiveEntry.1.3
ituAlarmActiveTrendIndication    moreSevere (1)
ituAlarmDetector                   0.0
ituAlarmServiceProvider            0.0
ituAlarmServiceUser                0.0
alarmActiveVariableIndex                 1
alarmActiveVariableID                    sysUpTime.0
alarmActiveVariableValueType             timeTicks(3)
alarmActiveVariableCounter32Val          0
alarmActiveVariableUnsigned32Val         0
alarmActiveVariableTimeTicksVal          46754
alarmActiveVariableInteger32Val          0
alarmActiveVariableOctetStringVal        ""
alarmActiveVariableIpAddressVal          0
alarmActiveVariableOidVal                0.0
alarmActiveVariableCounter64Val          0
alarmActiveVariableIndex                 2
alarmActiveVariableID                    snmpTrapOID.0
alarmActiveVariableValueType             objectId(7)
alarmActiveVariableCounter32Val          0
alarmActiveVariableUnsigned32Val         0
alarmActiveVariableTimeTicksVal          0
alarmActiveVariableInteger32Val          0
alarmActiveVariableOctetStringVal        ""
alarmActiveVariableIpAddressVal          0
alarmActiveVariableOidVal                1.3.6.1.6.3.1.1.5.3
alarmActiveVariableCounter64Val          0
alarmActiveVariableIndex                 3
alarmActiveVariableID                    ifIndex
alarmActiveVariableValueType             integer32(4)
alarmActiveVariableCounter32Val          0
alarmActiveVariableUnsigned32Val         0
alarmActiveVariableTimeTicksVal          0
alarmActiveVariableInteger32Val          346
alarmActiveVariableOctetStringVal        ""
alarmActiveVariableIpAddressVal          0
alarmActiveVariableOidVal                0.0
alarmActiveVariableCounter64Val          0
alarmActiveVariableIndex                 4
alarmActiveVariableID                    ifAdminStatus
alarmActiveVariableValueType             integer32(4)
alarmActiveVariableCounter32Val          0
alarmActiveVariableUnsigned32Val         0
alarmActiveVariableTimeTicksVal          0
alarmActiveVariableInteger32Val          up (1)
alarmActiveVariableOctetStringVal        ""
alarmActiveVariableIpAddressVal          0
alarmActiveVariableOidVal                0.0
alarmActiveVariableCounter64Val          0
alarmActiveVariableIndex                 5
alarmActiveVariableID                    ifOperStatus
alarmActiveVariableValueType             integer32(4)
alarmActiveVariableCounter32Val          0
alarmActiveVariableUnsigned32Val         0
alarmActiveVariableTimeTicksVal          0
alarmActiveVariableInteger32Val          down(2)
alarmActiveVariableOctetStringVal        ""
alarmActiveVariableIpAddressVal          0
alarmActiveVariableOidVal                0.0
alarmActiveVariableCounter64Val          0
alarmActiveVariableOpaqueVal

Temperature Alarms Using Generic Notifications

Consider a system able to detect four different temperature states for a widget - normal, minor, major, critical. The system does not have any Notification definitions for these alarm states. A temperature alarm can be modelled using the generic alarm Notifications of alarmClearState and alarmActive.

alarmModelIndex 5 alarmModelState 1 alarmModelNotificationId alarmClearState alarmModelVarbindIndex 2 alarmModelVarbindValue cleared (1) alarmModelDescription "Acme Widget Temperature Normal" alarmModelSpecificPointer ituAlarmEntry.5.1 alarmModelVarbindSubtree alarmActiveResourceId alarmModelResourcePrefix 0.0 alarmModelRowStatus active (1) ituAlarmEventType environmentalAlarm (6) ituPerceivedSeverity cleared (1) ituAlarmGenericModel alarmModelEntry.5.1

alarmModelIndex 5 alarmModelState 2 alarmModelNotificationId alarmActiveState alarmModelVarbindIndex 2 alarmModelVarbindValue minor (5) alarmModelDescription "Acme Widget Temperature Minor" alarmModelSpecificPointer ituAlarmEntry.5.5 alarmModelVarbindSubtree alarmActiveResourceId alarmModelResourcePrefix 0.0 alarmModelRowStatus active (1) ituAlarmEventState environmentalAlarm (6) ituPerceivedSeverity minor (5) ituAlarmGenericModel alarmModelEntry.5.2

alarmModelIndex 5 alarmModelState 3 alarmModelNotificationId alarmActiveState alarmModelVarbindIndex 2 alarmModelVarbindValue major (4) alarmModelDescription "Acme Widget Temperature Major" alarmModelSpecificPointer ituAlarmEntry.5.4 alarmModelVarbindSubtree alarmActiveResourceId alarmModelResourcePrefix 0.0

alarmModelRowStatus active (1) ituAlarmEventType environmentalAlarm (6) ituPerceivedSeverity major (4) ituAlarmGenericModel alarmModelEntry.5.3 alarmModelIndex 5 alarmModelState 4 alarmModelNotificationId alarmActiveState alarmModelVarbindIndex 2 alarmModelVarbindValue critical (3) alarmModelDescription "Acme Widget Temperature Critical" alarmModelSpecificPointer ituAlarmEntry.5.3 alarmModelVarbindSubtree alarmActiveResourceId alarmModelResourcePrefix 0.0 alarmModelRowStatus active (1) ituAlarmEventType environmentalAlarm (6) ituPerceivedSeverity critical (3) ituAlarmGenericModel alarmModelEntry.5.4

Temperature Alarms Without Notifications

Consider a system able to detect four different temperature states for a widget - normal, minor, major, critical. The system does not have any Notification definitions for these alarm states. A temperature alarm can be modelled without specifying any Notifications in the alarm model. When a temperature state other than normal is detected, an instance of this alarm would be added to the active alarm table, but no Notifications would be sent out.

This could alternatively be accomplished using the models from example 6.2 and by not specifying any target managers in the SNMP- TARGET-MIB, which would allow the alarm state Notifications to be logged in the Notification Log while still preventing Notifications from being transmitted on the wire.

alarmModelIndex 6 alarmModelState 1 alarmModelNotificationId 0.0 alarmModelVarbindIndex 0 alarmModelVarbindValue 0 alarmModelDescription "Widget Temperature" alarmModelSpecificPointer ituAlarmEntry.6.1 alarmModelVarbindSubtree 0.0 alarmModelResourcePrefix 0.0 alarmModelRowStatus active (1) ituAlarmEventType environmentalAlarm (6) ituPerceivedSeverity cleared (1) ituAlarmGenericModel alarmModelEntry.6.1

alarmModelIndex 6 alarmModelState 2 alarmModelNotificationId 0.0 alarmModelVarbindIndex 0 alarmModelVarbindValue 0 alarmModelDescription "Widget Temperature" alarmModelSpecificPointer ituAlarmEntry.6.5 alarmModelVarbindSubtree 0.0 alarmModelResourcePrefix 0.0 alarmModelRowStatus active (1) ituAlarmEventState environmentalAlarm (6) ituAlarmPerceivedSeverity minor (5) ituAlarmGenericModel alarmModelEntry.6.2

alarmModelIndex 6 alarmModelState 3 alarmModelNotificationId 0.0 alarmModelVarbindIndex 0 alarmModelVarbindValue 0 alarmModelDescription "Widget Temperature" alarmModelSpecificPointer ituAlarmEntry.6.4 alarmModelVarbindSubtree 0.0 alarmModelResourcePrefix 0.0 alarmModelRowStatus active (1) ituAlarmEventType environmentalAlarm (6) ituPerceivedSeverity major (4) ituAlarmGenericModel alarmModelEntry.6.3

alarmModelIndex 6 alarmModelState 4 alarmModelNotificationId 0.0 alarmModelVarbindIndex 0 alarmModelVarbindValue 0 alarmModelDescription "Widget Temperature Severe" alarmModelSpecificPointer ituAlarmEntry.6.3 alarmModelVarbindSubtree 0.0 alarmModelResourcePrefix 0.0 alarmModelRowStatus active (1) ituAlarmEventType environmentalAlarm (6) ituPerceivedSeverity critical (3) ituAlarmGenericModel alarmModelEntry.6.4

Printer MIB Alarm Example

Consider the following Notifications defined in the printer MIB RFC3805:

prtAlertSeverityLevel OBJECT-TYPE

-- This value is a type 1 enumeration
SYNTAX     INTEGER {
             other(1),
             critical(3),
             warning(4)
         }
MAX-ACCESS read-only
STATUS     current
DESCRIPTION
  "The level of severity of this alert table entry.  The printer
  determines the severity level assigned to each entry into the
  table."
::= { prtAlertEntry 2 }

printerV2Alert NOTIFICATION-TYPE

OBJECTS { prtAlertIndex, prtAlertSeverityLevel, prtAlertGroup,
        prtAlertGroupIndex, prtAlertLocation, prtAlertCode }
STATUS  current
DESCRIPTION
  "This trap is sent whenever a critical event is added to the
  prtAlertTable."
::= { printerV2AlertPrefix 1 }

These Notifications can be used to model a printer alarm as follows:

alarmModelIndex 9 alarmModelState 1 alarmModelNotificationId alarmClearState alarmModelVarbindIndex 0 alarmModelVarbindValue 0 alarmModelDescription "Printer Alarm" alarmModelSpecificPointer 0.0 alarmModelVarbindSubtree prtAlertGroup alarmModelResourcePrefix 0.0 alarmModelRowStatus active (1)

alarmModelIndex 9 alarmModelState 2 alarmModelNotificationId printerV2Alert alarmModelVarbindIndex 2 alarmModelVarbindValue warning (4) alarmModelDescription "Printer Alarm" alarmModelSpecificPointer 0.0 alarmModelVarbindSubtree prtAlertGroup alarmModelResourcePrefix 0.0 alarmModelRowStatus active (1)

alarmModelIndex 9 alarmModelState 3

alarmModelNotificationId printerV2Alert alarmModelVarbindIndex 2 alarmModelVarbindValue other (1) alarmModelDescription "Printer Alarm - unknown severity" alarmModelSpecificPointer 0.0 alarmModelVarbindSubtree prtAlertGroup alarmModelResourcePrefix 0.0 alarmModelRowStatus active (1)

alarmModelIndex 9 alarmModelState 4 alarmModelNotificationId printerV2Alert alarmModelVarbindIndex 2 alarmModelVarbindValue critical (3) alarmModelDescription "Printer Alarm" alarmModelSpecificPointer 0.0 alarmModelVarbindSubtree prtAlertGroup alarmModelResourcePrefix 0.0 alarmModelRowStatus active (1)

RMON Alarm Example

The RMON MIB RFC2819 defines a mechanism for generating threshold alarms. When the thresholds are crossed, RisingAlarm and FallingAlarm Notifications are generated as appropriate. These Notifications can be used to model an upper threshold alarm as follows:

alarmModelIndex 6 alarmModelState 1 alarmModelNotificationId FallingAlarm alarmModelVarbindIndex 0 alarmModelVarbindValue 0 alarmModelDescription "RMON Rising Clear Alarm" alarmModelSpecificPointer 0.0 alarmModelVarbindSubtree alarmIndex alarmModelResourcePrefix 0.0 alarmModelRowStatus active (1)

alarmModelIndex 6 alarmModelState 2 alarmModelNotificationId RisingAlarm alarmModelVarbindIndex 0 alarmModelVarbindValue 0 alarmModelDescription "RMON Rising Alarm" alarmModelSpecificPointer 0.0 alarmModelVarbindSubtree alarmIndex alarmModelResourcePrefix 0.0 alarmModelRowStatus active (1)

The Lifetime of an Alarm

The following example demonstrates the relationship between the active alarm table, the clear alarm table and the Notification Log MIB.

Consider a system with alarms modelled as in example 1 and which also supports the informational Notification dsx3LineStatusChange.

dsx3LineStatusChange NOTIFICATION-TYPE

OBJECTS { dsx3LineStatus,
          dsx3LineStatusLastChange }
STATUS  current
DESCRIPTION
        "A dsx3LineStatusChange trap is sent when the
        value of an instance of dsx3LineStatus changes.  It
        can be utilized by an NMS to trigger polls.  When
        the line status change results in a lower level
        line status change (i.e., ds1), then no traps for
        the lower level are sent."
           ::= { ds3Traps 0 1 }

At system start, the active alarm table, alarm clear table and

the Notification Log are all empty.

     ___________________________     _______________________
    | alarmActiveTable          |   | nlmLogTable           |
    |---------------------------|   |-----------------------|
    | alarmActiveIndex |  alarm |   | nlmLogPointer | notif.|
    |---------------------------|   |-----------------------|
    |___________________________|   |_______________________|
     __________________________________________________
    | alarmClearTable                                  |
    |--------------------------------------------------|
    | alarmClear Index |  alarm                        |
    |--------------------------------------------------|
    |                  |                               |
    |__________________________________________________|

Some time later, a link goes down generating a linkDown

Notification, which is sent out and logged in the Notification Log. As this Notification is modelled as an alarm state, an entry is added to the active alarm table.

     __________________________________________________
    | alarmActiveTable                                 |
    |--------------------------------------------------|
    | alarmActiveIndex |  alarm                        |
    |--------------------------------------------------|
    |        1         | link down - problem confirmed |
    |__________________________________________________|
     _______________________________________________
    | nlmLogTable                                   |
    |-----------------------------------------------|
    | nlmLogPointer |  Notification                 |
    |-----------------------------------------------|
    |      1        | linkdown                      |
    |_______________________________________________|
     __________________________________________________
    | alarmClearTable                                  |
    |--------------------------------------------------|
    | alarmClear Index |  alarm                        |
    |--------------------------------------------------|
    |                  |                               |
    |__________________________________________________|

Some time later, the value of an instance of dsx3LineStatus

changes. This Notification is sent out and logged. As this is not modelled into an alarm state, the active alarm table remains unchanged.

     __________________________________________________
    | alarmActiveTable                                 |
    |--------------------------------------------------|
    | alarmActiveIndex |  alarm                        |
    |--------------------------------------------------|
    |        1         | linkDown - problem confirmed  |
    |__________________________________________________|
     _____________________________________________
    | nlmLogTable                                 |
    |---------------------------------------------|
    | nlmLogPointer |  Notification               |
    |---------------------------------------------|
    |      1        | linkDown                    |
    |      2        | dsx3LineStatusChange        |
    |_____________________________________________|
     __________________________________________________
    | alarmClearTable                                  |
    |--------------------------------------------------|
    | alarmClear Index |  alarm                        |
    |--------------------------------------------------|
    |                  |                               |
    |__________________________________________________|

Some time later, the link goes back up. A linkUp Notification

is sent out and logged. As this Notification models the clear alarm for this alarm, the alarm entry is remove from the active alarm table. An entry is added to the clear alarm table.

     __________________________________________________
    | alarmActiveTable                                 |
    |--------------------------------------------------|
    | alarmActiveIndex |  alarm                        |
    |--------------------------------------------------|
    |__________________________________________________|
     _____________________________________________
    | nlmLogTable                                 |
    |---------------------------------------------|
    | nlmLogPointer |  Notification               |
    |---------------------------------------------|
    |      1      | linkDown                      |
    |      2      | dsx3LineStatusChange          |
    |      3      | linkUp                        |
    |_____________________________________________|
     __________________________________________________
    | alarmClearTable                                  |
    |--------------------------------------------------|
    | alarmClear Index |  alarm                        |
    |--------------------------------------------------|
    |      1           | linkDown - confirmed problem  |
    |__________________________________________________|

Security Considerations

There are a number of management objects defined in this MIB module with a MAX-ACCESS clause of read-write and/or read-create. Such objects may be considered sensitive or vulnerable in some network environments. The support for SET operations in a non-secure environment without proper protection can have a negative effect on network operations.

The following objects are defined with a MAX-ACCESS clause of read- write or read-create: alarmModelNotificationId, alarmModelVarbindIndex, alarmModelVarbindValue, alarmModelDescription, alarmModelSpecificPointer, alarmModelVarbindSubtree, alarmModelResourcePrefix, alarmModelRowStatus, alarmClearMaximum, ituAlarmEventType, ituAlarmProbableCause, ituAlarmAdditionalText, and ituAlarmGenericModel.

Note that setting the value of alarmClearMaximum too low may result in security related alarms history being prematurely lost.

Changing values of alarmModelRowStatus as part of creating and deleting rows in the alarmModelTable result in adding new alarm models to the system or taking them out respectively. These operations need to be carefully planned. Adding a new model should be made in a consistent manner to avoid the system overflow with alarms. Taking out a model should result in the deletion of all this model's related alarms in the system.

SNMP versions prior to SNMPv3 did not include adequate security. Even if the network itself is secure (for example by using IPSec), even then, there is no control as to who on the secure network is allowed to access and GET/SET (read/change/create/delete) the objects in this MIB module.

It is RECOMMENDED that implementers consider the security features as provided by the SNMPv3 framework (see RFC3410, section 8), including full support for the SNMPv3 cryptographic mechanisms (for authentication and privacy).

Further, deployment of SNMP versions prior to SNMPv3 is NOT RECOMMENDED. Instead, it is RECOMMENDED to deploy SNMPv3 and to enable cryptographic security. It is then a customer/operator responsibility to ensure that the SNMP entity giving access to an instance of this MIB module is properly configured to give access to the objects only to those principals (users) that have legitimate rights to indeed GET or SET (change/create/delete) them.

Note that the alarm throttling mechanism associated with the alarmActiveState and alarmActiveClear notifications only applies to a given alarm. Defining multiple alarms from the same internal stimulus may then still result in a flood of alarms into the network.

Although the use of community strings in SNMPv1 is not considered an effective means of providing security, security administrators SHOULD consider whether the fact that alarmActiveContextName can reveal community string values would make this object sensitive in their environment.

This MIB module can provide access to information that may also be accessed through manipulation of the SNMP-NOTIFICATION-MIB and the NOTIFICATION-LOG-MIB. This is expressed in part through the common indexing structure of nlmLogName RFC3014, snmpNotifyFilterProfileName RFC3413, and alarmListName. Consequently, it is RECOMMENDED that security administrators take care to configure a coherent VACM security policy. The objects

alarmActiveLogPointer, alarmActiveModelPointer, alarmActiveSpecificPointer, and alarmClearModelPointer are object identifiers that reference information to which a particular user might not be given direct access. The structure of these object identifiers does not permit the extraction of any sensitive information. Two other objects, alarmClearResourceId, and alarmActiveResourceId, are also syntactically object identifiers, but their structure could provide a user with potentially useful information to which he or she might not otherwise be granted access, such as the existence of a particular resource.

For further discussion of security, see section 3.4.

Acknowledgements

This document is a product of the DISMAN Working Group.

References

Normative References

[M.3100] ITU Recommendation M.3100, "Generic Network Information

           Model", 1995

RFC1157 Case, J., Fedor, M., Schoffstall, M. and J. Davin,

           "Simple Network Management Protocol (SNMP)", STD 15, RFC
           1157, May 1990.

RFC1215 Rose, M., "A Convention for defining traps for use with

           the SNMP", RFC 1215, March 1991.

RFC2021 Waldbusser, S., "Remote Network Monitoring Management

           Information Base Version 2 using SMIv2", January 1997.

RFC2119 Bradner, S., "Key words for use in RFCs to Indicate

           Requirement Levels", BCP 14, RFC 2119, March 1997.

RFC2578 McCloghrie, K., Perkins, D. and J. Schoenwaelder,

           "Structure of Management Information Version 2 (SMIv2)",
           STD 58, RFC 2578, April 1999.

RFC2579 McCloghrie, K., Perkins, D. and J. Schoenwaelder,

           "Textual Conventions for SMIv2", STD 58, RFC 2579, April
           1999.

RFC2580 McCloghrie, K., Perkins, D. and J. Schoenwaelder,

           "Conformance Statements for SMIv2", STD 58, RFC 2580,
           April 1999.

RFC3291 Daniele, M., Haberman, B., Routhier, S. and J.

           Schoenwaelder, "Textual Conventions for Internet Network
           Addresses", RFC 3291, May 2002.

RFC3411 Harrington, D., Presuhn, R. and B. Wijnen, "An

           Architecture for Describing Simple Network Management
           Protocol (SNMP) Management Frameworks", STD 62, RFC 3411,
           December 2002.

RFC3413 Levi, D., Meyer, P. and B. Stewart, "Simple Network

           Management Protocol (SNMP) Applications", STD 62, RFC
           3414, December 2002.

RFC3415 Wijnen, B., Presuhn, R. and K. McCloghrie, "View-based

           Access Control Model (VACM) for the Simple Network
           Management Protocol (SNMP)", STD 62, RFC 3415, December
           2002.

RFC3416 Presuhn, R., Ed., "Version 2 of the Protocol Operations

           for the Simple Network Management Protocol (SNMP)", STD
           62, RFC 3416, December 2002.

RFC3584 Frye, R., Levi, D., Routhier, S. and B. Wijnen,

           "Coexistence between Version 1, Version 2, and Version 3
           of the Internet-standard Network Management Framework",
           BCP 74, RFC 3584, August 2003.

[X.733] ITU Recommendation X.733, "Information Technology - Open

           Systems Interconnection - System Management: Alarm
           Reporting Function", 1992.

[X.736] ITU Recommendation X.736, "Information Technology - Open

           Systems Interconnection - System Management: Security
           Alarm Reporting Function", 1992.

Informative References

RFC1657 Willis, S., Burruss, J. and J. Chu, Ed., "Definitions of

           Managed Objects for the Fourth Version of the Border
           Gateway Protocol (BGP-4) using SMIv2", RFC 1657, July
           1994.

RFC2737 McCloghrie, K. and A. Bierman, "Entity MIB (version 2)",

           RFC 2737, December 1999.

RFC2819 Waldbusser, S. "Remote Network Monitoring Management

           Information Base", STD 59, RFC 2819, May 2000.

RFC2863 McCloghrie, K. and F. Kastenholz, "The Interfaces Group

           MIB using SMIv2", RFC 2863, June 2000.

RFC2981 Kavasseri, R., Ed., "Event MIB", RFC 2981, October 2000.

RFC3014 Kavasseri, R., "Notification Log MIB", RFC 3014, November

           2000.

RFC3410 Case, J., Mundy, R., Partain, D. and B. Stewart,

           "Introduction and Applicability Statements for Internet-
           Standard Management Framework", RFC 3410, December 2002.

RFC3418 Presuhn, R., Ed., "Management Information Base (MIB) for

           the Simple Network Management Protocol (SNMP)", STD 62,
           RFC 3418, December 2002.

RFC3805 Bergman, R., Lewis, H. and I. McDonald, "Printer MIB v2",

           RFC 3805, June 2004.

10. Authors' Addresses

Sharon Chisholm Nortel Networks PO Box 3511, Station C Ottawa, Ontario, K1Y 4H7 Canada

EMail: [email protected]

Dan Romascanu Avaya Atidim Technology Park, Bldg. #3 Tel Aviv, 61131 Israel

Phone: +972-3-645-8414 EMail: [email protected]

11. Full Copyright Statement

Copyright (C) The Internet Society (2004). This document is subject to the rights, licenses and restrictions contained in BCP 78, and except as set forth therein, the authors retain all their rights.

This document and the information contained herein are provided on an "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Intellectual Property

The IETF takes no position regarding the validity or scope of any Intellectual Property Rights or other rights that might be claimed to pertain to the implementation or use of the technology described in this document or the extent to which any license under such rights might or might not be available; nor does it represent that it has made any independent effort to identify any such rights. Information on the procedures with respect to rights in RFC documents can be found in BCP 78 and BCP 79.

Copies of IPR disclosures made to the IETF Secretariat and any assurances of licenses to be made available, or the result of an attempt made to obtain a general license or permission for the use of such proprietary rights by implementers or users of this specification can be obtained from the IETF on-line IPR repository at http://www.ietf.org/ipr.

The IETF invites any interested party to bring to its attention any copyrights, patents or patent applications, or other proprietary rights that may cover technology that may be required to implement this standard. Please address the information to the IETF at ietf- [email protected].

Acknowledgement

Funding for the RFC Editor function is currently provided by the Internet Society.